Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens

被引:8
作者
Shin, Da Eun [1 ]
Lee, Hun [2 ]
Koh, Kyungmin [1 ]
机构
[1] Konyang Univ, Dept Ophthalmol, Kims Eye Hosp, Coll Med, 136 Youngshinro, Seoul 07301, South Korea
[2] Univ Ulsan, Dept Ophthalmol, Asan Med Ctr, Coll Med, Seoul, South Korea
关键词
Continuous range of vision; Extended depth of focus; Intermediate vision; Intraocular lens; Near vision; PATIENT SATISFACTION; CONTRAST SENSITIVITY; VISUAL OUTCOMES; IMPLANTATION; QUALITY; VISION; IOL;
D O I
10.1186/s12886-022-02516-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Recently, a new presbyopia-correcting intraocular lens (IOL) that combines extended depth-of-focus and bifocal profiles (ZFR00: Tecnis (R) Synergy (R), Johnson & Johnson Vision, Santa Ana, CA, USA) has been established and several studies have been reported. We attempted to compare the performance with a standard IOL (ZCB00: Tecnis (R) monofocal, Johnson & Johnson Vision, Santa Ana, CA, USA) manufactured using the same material from the same company, which has been extensively used worldwide. Methods The medical records of patients undergoing cataract surgery with ZCB00 or ZFR00 implantation between March 2021 and September 2021 and with available 3-month visit data were reviewed. Uncorrected near, intermediate, and distance visual acuity (VA), corrected distance VA, and optical quality were the main outcome measures. Results This study included forty-six patients (64 eyes), with twenty-one patients (32 eyes) implanted with ZCB00 and twenty-five patients (32 eyes) implanted with ZFR00. The average age of the patients was 66.0 +/- 10.1 (range: 40 to 82) and 65.1 +/- 4.7 (range: 59 to 77) years in the ZCB00 and ZFR00 groups, respectively. The preoperative characteristics did not differ significantly between the two groups. Compared to the ZCB00 group, the ZFR00 group demonstrated significantly superior intermediate and near VA (p < 0.001) at 3 months postoperatively. The ZFR00 group showed significantly lower objective measured optical quality than that in the ZCB00 group. Conclusions The ZFR00 exhibited a continuous range of vision and a smooth defocus curve, while the ZCB00 provided superior objective optical quality.
引用
收藏
页数:7
相关论文
共 36 条
[1]   Preclinical metrics to predict through-focus visual acuity for pseudophakic patients [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Rosen, Robert ;
Weeber, Henk ;
Tsai, Linda ;
Hileman, Kendra ;
Piers, Patricia .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05) :1877-1888
[2]   Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses [J].
Altemir-Gomez, Irene ;
Millan, Maria S. ;
Vega, Fidel ;
Bartol-Puyal, Francisco ;
Gimenez-Calvo, Galadriel ;
Larrosa, Jose M. ;
Polo, Vicente ;
Pablo, Luis E. ;
Garcia-Martin, Elena .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) :299-306
[3]  
Chung Jin Kwon, 2019, Korean J Ophthalmol, V33, P451, DOI 10.3341/kjo.2019.0064
[4]   Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation - Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision [J].
Denoyer, Alexandre ;
Le Lez, Marie-Laure ;
Majzoub, Samuel ;
Pisella, Pierre-Jean .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02) :210-216
[5]  
Ferreira TB., 2022, J CATARACT REFR SURG, V48, P280, DOI [10.1097/j.jcrs.0000000000000743, DOI 10.1097/J.JCRS.0000000000000743]
[6]   Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens [J].
Gabric, Nikica ;
Gabric, Ivan ;
Gabric, Kresimir ;
Biscevic, Alma ;
Pinero, David P. ;
Bohac, Maja .
JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (04) :256-+
[7]   Visual and satisfaction results with implantation of the trifocal Panoptix? intraocular lens in cataract surgery [J].
Galvis, Virgilio ;
Escaf, Luis C. ;
Escaf, Luis J. ;
Tello, Alejandro ;
Rodriguez, Lisi D. ;
Lapid-Gortzak, Ruth ;
Carreno, Nestor I. ;
Berrospi, Ruben D. ;
Nino, Camilo A. ;
Viberg, Andreas ;
Camacho, Paul A. .
JOURNAL OF OPTOMETRY, 2022, 15 (03) :219-227
[8]  
Galvis V, 2020, J CATARACT REFR SURG, V46, P803, DOI 10.1097/j.jcrs.0000000000000158
[9]   Visual acuity and defocus curves with six multifocal intraocular lenses [J].
Gil, Miguel A. ;
Varon, Consuelo ;
Cardona, Genis ;
Buil, Jose A. .
INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (02) :393-401
[10]   The Quest for Spectacle Independence: A Comparison of Multifocal Intraocular Lens Implants and Pseudophakic Monovision for Patients with Presbyopia [J].
Greenstein, Steven ;
Pineda, Roberto .
SEMINARS IN OPHTHALMOLOGY, 2017, 32 (01) :111-115