Computer-aided technology for fabricating removable partial denture frameworks: A systematic review and meta-analysis

被引:27
作者
Pordeus, Mariana Domingues [1 ]
Santiago, Joel Ferreira [2 ]
Venante, Helena Sandrini [1 ,3 ]
da Costa, Rodrigo Moreira Bringel [1 ]
Chocano, Ana Paula Chappuis [1 ]
Porto, Vinicius Carvalho [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Bauru, FOB USP, Octavio Pinheiro Brisolla, Bauru, SP, Brazil
[2] UNISAGRADO, Ctr Univ Sagrado Coracao, Bauru, SP, Brazil
[3] FOB USP, Dent Sch Bauru, 9-75 Al Dr Octavio Pinheiro Brisolla, BR-17012901 Bauru, SP, Brazil
关键词
CAD/CAM TECHNOLOGY; DESIGN; ACCURACY; IMPLANTS; PEEK; CAD;
D O I
10.1016/j.prosdent.2020.06.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A consensus that establishes the indications and clinical performance of removable partial denture (RPD) frameworks designed and manufactured with computer-aided design and computer-aided manufacturing (CAD-CAM) systems is lacking. Purpose. The purpose of this systematic review and meta-analysis was to evaluate the currently published literature investigating different CAD-CAM methods and techniques for RPD manufacturing and their clinical performance. Material and methods. A comprehensive search of studies published up to September 2019 was performed in PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA Statement) criteria and was registered and approved in the International Prospective Register of Systematic Reviews (PROSPERO: CRD42020152197). The population, intervention, comparison, outcome (PICO) question was "Do the CAD -CAM frameworks have similar performances to those fabricated by conventional techniques?" The meta -analysis included clinical and in vitro studies based on the effect size and test of Null (2-Tail) with 95% confidence interval (CI). Clinical and in vitro studies were selected and analyzed separately. Results. A total of 15 articles out of 358 were selected. For clinical studies, quantitative analysis with a sample of 25 participants showed a mean discrepancy between occlusal rests and rest seats of 184.91 mm (95% CI: 152.6 mm-217.15 mm) and heterogeneity (I2) of 0%. Clinical data considered that frameworks were acceptable for continuity of treatment. The predominant materials were cobalt-chromium (Co-Cr) and polyetheretherketone (PEEK), and studies using Co-Cr reported that the structure required adjustments. In addition, it has been reported that the indirect technique was time-consuming and selective laser melting (SLM) can be costly. PEEK structures have been more widely accepted because of improved esthetics. Quantitative data from the in vitro studies revealed that the additive manufacturing technique (2.006 mm: 95% CI:-2.021 mm to 6.032 mm) was not significantly different from the indirect technique (0.026 mm; P=.455; random: I2: 98.402%). Conclusions. Clinical studies and in vitro research on CAD-CAM planning and manufacturing of removable prosthesis frameworks are still sparse. However, preliminary data indicate a similar fit and esthetic improvement when compared with the conventional technique. (J Prosthet Dent 2022;128:331-40)
引用
收藏
页码:331 / 340
页数:10
相关论文
共 41 条
[1]   Advancements in CAD/CAM technology: Options for practical implementation [J].
Alghazzawi, Tariq F. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) :72-84
[2]   Peri-implant marginal bone level: a systematic review and meta-analysis of studies comparing platform switching versus conventionally restored implants [J].
Annibali, Susanna ;
Bignozzi, Isabella ;
Cristalli, Maria Paola ;
Graziani, Filippo ;
La Monaca, Gerardo ;
Polimeni, Antonella .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (11) :1097-1113
[3]  
[Anonymous], 2013, Asthma Facts: CDC's National Asthma Control Program Grantees, P1, DOI [10.17226/14668, DOI 10.17226/14668]
[4]   Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology [J].
Arafa, Khalid A. O. .
SAUDI MEDICAL JOURNAL, 2018, 39 (01) :17-22
[5]   Accuracy of CAD-CAM-fabricated removable partial dentures [J].
Arnold, Christin ;
Hey, Jeremias ;
Schweyen, Ramona ;
Setz, Juergen M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :586-592
[6]  
Bajunaid Salwa O, 2019, J Contemp Dent Pract, V20, P476, DOI 10.5005/jp-journals-10024-2542
[7]   Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques [J].
Bibb, R. J. ;
Eggbeer, D. ;
Williams, R. J. ;
Woodward, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H7) :793-797
[8]  
Borenstein M., 2009, Introduction to meta-analysis, DOI 10.1002/9780470743386
[9]   THE TOOTH-REMOVABLE PARTIAL DENTURE INTERFACE [J].
BRUDVIK, JS ;
REIMERS, D .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06) :924-927
[10]  
Budak I., 2012, J Archive Mater Manuf Eng, V54, P233