Stenting vs. balloon angioplasty for discrete unoperated coarctation of the aorta in adolescents and adults

被引:70
作者
Pedra, CAC [1 ]
Fontes, VF [1 ]
Esteves, CA [1 ]
Pilla, CB [1 ]
Braga, SLN [1 ]
Pedra, SRF [1 ]
Santana, MVT [1 ]
Silva, MAP [1 ]
Almeida, T [1 ]
Sousa, JEMR [1 ]
机构
[1] Inst Dante Pazzanese Cardiol, Pediat Catherizat Lab, BR-04012180 Sao Paulo, Brazil
关键词
coarctation of the aorta; stents; balloon; congenital heart disease; interventional cardiology;
D O I
10.1002/ccd.20311
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
More information is needed to clarify whether stenting is superior to balloon angioplasty (BA) for unoperated coarctation of the aorta (CoA). From September 1997, 21 consecutive adolescents and adults (24 +/- 11 years) with discrete CoA underwent stenting (G1). The results were compared to those achieved by BA performed in historical group of 15 patients (18 +/- 10 years; P = 0.103; G2). After the procedure, systolic gradient reduction was higher (99% +/- 2% vs. 87% +/- 17%; P = 0.015), residual gradients lower (0.4 +/- 1.4 vs. 5.9 +/- 7.9 mm Hg; P = 0.019), gain at the CoA site higher (333% +/- 172% vs. 190% +/- 104%; P = 0.007), and CoA diameter larger (16.9 +/- 2.9 vs. 12.9 +/- 3.2 mm; P < 0.001) in G1. Aortic wall abnormalities were found in eight patients in G2 (53%) and in one in G1 (7%; P < 0.001). There was no major complication. Repeat catheterization (n = 33) and/or MRI (n = 2) was performed at a median follow-up of 1.0 year for G1 and 1.5 for G2 (P = 0.005). Gradient reduction persisted in both groups, although higher late gradients were seen in G2 (median of 0 mm Hg for G1 vs. 3 for G2; P = 0.014). CoA diameter showed no late loss in G1 and a late gain in G2 with a trend to being larger in G1 (16.7 +/- 2.9 vs. 14.6 +/- 3.9 mm; P = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in G1. Aortic wall abnormalities did not progress and one patient required redilation in G2. Blood pressure was similar in both groups at follow-up (126 +/- 12/81 +/- 11 for G1 vs. 120 +/- 15/80 +/- 10 mm Hg for G2; P = 0.149 and 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, stenting was a better means to relieve the stenosis and minimize the risk of developing immediate aortic wall abnormalities. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:495 / 506
页数:12
相关论文
共 64 条
[1]   Endovascular treatment of thoracic disease: Patient selection and a proposal of a risk score [J].
Alves, CMR ;
da Fonseca, JHP ;
de Souza, JAM ;
Carvalho, ACC ;
Buffolo, E .
ANNALS OF THORACIC SURGERY, 2002, 73 (04) :1143-1148
[2]   EARLY RESULTS OF BALLOON ANGIOPLASTY OF NATIVE AORTIC COARCTATION IN YOUNG-ADULTS [J].
ATTIA, IM ;
LABABIDI, ZA .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (11) :930-931
[3]  
BENSON L, 2004, NATURAL MODIFIED HIS, P251
[4]  
Bulbul ZR, 1996, CATHETER CARDIO DIAG, V39, P36, DOI 10.1002/(SICI)1097-0304(199609)39:1<36::AID-CCD7>3.3.CO
[5]  
2-Z
[6]   LEFT-VENTRICULAR HYPERKINESIA AT REST AND DURING EXERCISE IN NORMOTENSIVE PATIENTS 2 TO 27 YEARS AFTER COARCTATION REPAIR [J].
CARPENTER, MA ;
DAMMANN, JF ;
WATSON, DD ;
JEDEIKIN, R ;
TOMPKINS, DG ;
BELLER, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (04) :879-886
[7]   Stenting of coarctation of the aorta [J].
Cheatham, JP .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) :112-125
[8]  
CHEATHAM JP, 2003, CATHETER BASED DEVIC, P353
[9]   PARADOXICAL HYPERTENSION AFTER REPAIR OF COARCTATION OF THE AORTA IN CHILDREN - BALLOON ANGIOPLASTY VERSUS SURGICAL REPAIR [J].
CHOY, M ;
ROCCHINI, AP ;
BEEKMAN, RH ;
ROSENTHAL, A ;
DICK, M ;
CROWLEY, D ;
BEHRENDT, D ;
SNIDER, AR .
CIRCULATION, 1987, 75 (06) :1186-1191
[10]  
COULSON JD, 2003, CATHETER BASED DEVIC, P285