Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs

被引:12
作者
Haenle, Maximilian [1 ]
Mittelmeier, Wolfram [1 ]
Barbano, Rodrigo [2 ]
Woertler, Klaus [3 ]
Scholz, Roger [4 ]
Bader, Rainer [1 ]
机构
[1] Univ Rostock, Orthopad Klin & Poliklin, D-18057 Rostock, Germany
[2] Tech Univ Munich, Klin & Poliklin Orthopadie & Sportorthopadie, Munich, Germany
[3] Tech Univ Munich, Inst Rontgendiagnost, Munich, Germany
[4] Univ Leipzig, Orthopad Klin & Poliklin, Leipzig, Germany
关键词
Total hip arthroplasty; Acetabular cup position; Radiographic evaluation; Intraobserver and interobserver reliability; Experimental model; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; POSITION; CT; REPLACEMENT; ORIENTATION; DISLOCATION; DEFINITION; STABILITY; COMPONENT;
D O I
10.1007/s00276-010-0682-9
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Purpose The purpose of this study was to compare different methods of evaluating the version of a metallic acetabular cup from plain radiographs and to compare them regarding their accuracy, inter- and intra-observer reliability. Methods Conventional anterior posterior radiographs were taken of a phantom-model at different defined ante- and retroversion angles of the acetabular cup. The version angles of the acetabular cup were derived according to four different established methods from the radiographs by five independent examiners. Results We were able to determine the radiographic version with the greatest accuracy according to a modified technique of Pettersson et al. Furthermore, we found the highest intra- and inter-observer reliability using this technique. Conclusions A modified technique of Pettersson et al. broadens the spectrum of applicability for the radiographic evaluation of the version angle of metal-backed acetabular cups in comparison to the originally introduced method. In clinical practice, however, the significance of deriving the cup position from standard radiographs should not be overestimated and therefore a computed tomography should be performed in certain critical cases.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 24 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]  
Aubry S, 2005, J RADIOL, V86, P399
[3]   The influence of head and neck geometry on stability of total hip replacement - A mechanical test study [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Zimmermann, S ;
Busch, R ;
Mittelmeier, W .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :415-421
[4]   Experimental analysis of standard, asymmetric and constraint liners for total hip replacement: Investigation of range of motion and stability against dislocation [J].
Bader, R ;
Steinhauser, E ;
Scholz, R ;
Simnacher, M ;
Mittelmeier, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (05) :577-585
[5]  
BADER R, 2004, JAHR SUDD ORTH, P242
[6]  
Eddine TA, 2001, SURG RADIOL ANAT, V23, P105
[7]   CT Outperforms Radiography for Determination of Acetabular Cup Version after THA [J].
Ghelman, Bernard ;
Kepler, Christopher K. ;
Lyman, Stephen ;
Della Valle, Alejandro Gonzalez .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2362-2370
[8]   Assessment of cup position from plain radiographs: impact of pelvic tilting [J].
Haenle, M. ;
Heitner, A. ;
Mittelmeier, W. ;
Barbano, R. ;
Scholz, R. ;
Steinhauser, E. ;
Bader, R. .
SURGICAL AND RADIOLOGIC ANATOMY, 2007, 29 (01) :29-35
[9]   RADIOGRAPHIC CALCULATION OF ANTEVERSION IN ACETABULAR PROSTHESES [J].
HASSAN, DM ;
JOHNSTON, GHF ;
DUST, WNC ;
WATSON, LG ;
CASSIDY, D .
JOURNAL OF ARTHROPLASTY, 1995, 10 (03) :369-372
[10]  
Hedlundh U, 1996, CLIN ORTHOP RELAT R, P226