Development of a New Precast Concrete Panel Wall System Incorporated with Energy Dissipative Dowel Connectors

被引:0
|
作者
Darama, Huseyin [1 ]
Shiohara, Hitoshi [1 ]
机构
[1] Arup N Amer Ltd, Los Angeles, CA USA
来源
SEISMIC RISK ASSESSMENT AND RETROFITTING: WITH SPECIAL EMPHASIS ON EXISTING LOW-RISE STRUCTURES | 2009年 / 10卷
关键词
D O I
10.1007/978-90-481-2681-1_12
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Conventional methods of earthquake resistant design rely on the ductile behavior of the structural member for energy dissipation. It is required that the structure yields and experiences damage without collapse under a catastrophic event. For newly built structures, ductility requirement can be achieved by providing special detailing where inelastic deformation expected. However, the situation is not straightforward and complex for the existing or poorly detailed structures. In most case, rehabilitation becomes impossible due to insufficient techniques, high costs and long down-time. As a response to these shortcomings, a new Precast Concrete Panel Wall (PCPW) system with dowel connectors is introduced herein. In a moderate event, proposed system relies on the energy dissipated by the dowel connectors at panel attachments. The hysteretic energy dissipation will be concentrated on specially designed connectors and this will reduce the inelastic demand on existing elements. However, under the action of a major event, panels will intact with the frame and contribute stiffness by a diagonal strut action. This will prevent from total collapse of the structure. The dual response mechanisms of PCPW systems inspire us considering them as an alternative passive control system that would be used in strengthening works.
引用
收藏
页码:237 / +
页数:2
相关论文
共 50 条
  • [21] Numerical investigation of a new precast concrete shear wall system with horizontal connections
    Han, Qihao
    Wang, Dayang
    Xu, Shenchun
    Zheng, Zhigang
    Mao, Jihua
    Structures, 2024, 70
  • [22] The cage wall: A new system for precast concrete walls without lattice girders
    Rapperstorfer, Hubert
    Betonwerk und Fertigteil-Technik/Concrete Plant and Precast Technology, 2016, 82 (02): : 165 - 167
  • [23] Seismic Resilience of Reinforced Concrete Frame Equipped with Energy Dissipative Cladding Panel System
    Wang, Xinyu
    Xie, Linlin
    Chong, Xun
    Sha, Huiling
    Yang, Cantian
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (03) : 617 - 636
  • [24] Accelerated aging tests of tensile strength of FRP connectors in precast concrete sandwich wall panels
    Xue, Weichen
    Fu, Kai
    Qin, Heng
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2014, 17 (03): : 420 - 424
  • [25] Experimental and Numerical Studies on the Seismic Performance of Precast Concrete Shear Wall Structures with an Energy Dissipation Cladding Panel
    Chong, Xun
    Sha, Huiling
    Xie, Linlin
    Li, Aiqun
    Jiang, Qing
    He, Yuanzhen
    Chen, Xi
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (06) : 3264 - 3279
  • [26] Development of a precast concrete shear-wall system requiring special code acceptance
    Bora, Can
    Oliva, Michael G.
    Nakaki, Suzanne Dow
    Becker, Roger
    PCI JOURNAL, 2007, 52 (01): : 122 - +
  • [27] Suitability of Coconut Shell Concrete for Precast Cool Wall Panel-A Review
    Shahidan, Shahiron
    Leman, Alif Syazani
    Senin, Mohamad Syamir
    Hannan, Nurul Izzati Raihan Ramzi
    9TH INTERNATIONAL UNIMAS STEM ENGINEERING CONFERENCE (ENCON 2016) INNOVATIVE SOLUTIONS FOR ENGINEERING AND TECHNOLOGY CHALLENGES, 2017, 87
  • [28] Experimental study on mechanical behaviour of replaceable energy dissipation connectors for precast concrete frames
    Xie, Luqi
    Wu, Jing
    Zhang, Jinyang
    Liu, Chenyu
    STRUCTURES, 2021, 33 : 3147 - 3162
  • [29] Experimental study on mechanical property of precast concrete frame with replaceable energy dissipation connectors
    Xie L.
    Wu J.
    Zhang J.
    Liu C.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2021, 51 (01): : 1 - 8
  • [30] Bending Performance of Precast Ceramsite-Concrete-Insulated Sandwich Panel with Stainless Steel Shear Connectors
    Chen, Yingjie
    Kang, Chaofeng
    Wu, Yunfeng
    Qian, Zhenxiao
    BUILDINGS, 2022, 12 (10)