Temperature-controlled ionic liquid-based ultrasound-assisted microextraction for preconcentration of trace quantity of cadmium and nickel by using organic ligand in artificial saliva extract of smokeless tobacco products

被引:19
作者
Arain, Sadaf Sadia [1 ]
Kazi, Tasneem Gul [1 ]
Arain, Asma Jabeen [1 ,2 ]
Afridi, Hassan Imran [1 ]
Baig, Jameel Ahmed [1 ]
Brahman, Kapil Dev [1 ]
Naeemullah [1 ]
Arain, Salma Aslam [1 ]
机构
[1] Sindh Univ, Natl Ctr Excellence Analyt Chem, Jamshoro 76080, Pakistan
[2] Muhammad Med Coll Mirpurkhas, Sindh, Pakistan
关键词
1-Butyl-3-methylimidazolium hexafluorophosphate; Cadmium; Lead; Microextraction; Artificial saliva; FLAME ATOMIC-ABSORPTION; WATER SAMPLES; SPECTROMETRIC DETERMINATION; TOXIC ELEMENTS; DRINKING-WATER; SYSTEM; METALS; ARECA; LEAD; COPPER(II);
D O I
10.1016/j.saa.2014.11.043
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A new approach was developed for the preconcentration of cadmium (Cd) and nickel (Ni) in artificial saliva extract of dry snuff (brown and black) products using temperature-controlled ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (TIL-UDLL mu E) followed by electrothermal atomic absorption spectrometry (ETAAS). The Cd and Ni were complexed with ammonium pyrrolidinedithiocarbamate (APDC), extracted in ionic liquid drops, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6]. The multivariate strategy was applied to estimate the optimum values of experimental variables influence the % recovery of analytes by TIL-UDLL mu E method. At optimum experimental conditions, the limit of detection (3s) were 0.05 and 0.14 mu g L-1 while relative standard deviations (% RSD) were 3.97 and 3.55 for Cd and Ni respectively. After extraction, the enhancement factors (EF) were 87 and 79 for Cd and Ni, respectively. The RSD for six replicates of 10 mu g L-1 Cd and Ni were 3.97% and 3.55% respectively. To validate the proposed method, certified reference material (CRM) of Virginia tobacco leaves was analyzed, and the determined values of Cd and Ni were in good agreement with the certified values. The concentration of Cd and Ni in artificial saliva extracts corresponds to 39-52% and 21-32%, respectively, of the total contents of both elements in dry brown and black snuff products. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 46 条
[1]   Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry [J].
Abulhassani, Jafar ;
Manzoori, Jamshid L. ;
Amjadi, Mohammad .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) :481-486
[2]   On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters [J].
Anthemidis, AN ;
Zachariadis, GA ;
Farastelis, CG ;
Stratis, JA .
TALANTA, 2004, 62 (03) :437-443
[3]   Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: Determination of lead and cadmium in natural waters [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2010, 668 (01) :35-40
[4]   Preconcentration of toxic elements in artificial saliva extract of different smokeless tobacco products by dual-cloud point extraction [J].
Arain, Sadaf Sadia ;
Kazi, Tasneem Gul ;
Arain, Jamshed Bashir ;
Afridi, Hassan Imran ;
Brahman, Kapil Dev ;
Naeemullah .
MICROCHEMICAL JOURNAL, 2014, 112 :42-49
[5]   Simultaneous preconcentration of toxic elements in artificial saliva extract of smokeless tobacco product, mainpuri by cloud point extraction method [J].
Arain, Sadaf Sadia ;
Kazi, Tasneem Gul ;
Arain, Jamshed Bashir ;
Afridi, Hassan Imran ;
Brahman, Kapil Dev ;
Shah, Faheem ;
Naeemullah ;
Arain, Salma ;
Panhwar, Abdul Haleem .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2013, 92 :289-296
[6]  
Asta J., 2003, J PHYS 4 P EDP SCI, P65
[7]  
Baars A.J., 2001, REEVALUATION HUMAN T
[8]   Ultrasound in analytical chemistry [J].
Capote, F. Priego ;
Luque de Castro, M. D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :249-257
[9]   On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer [J].
Cerutti, S ;
Silva, MF ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) :43-50
[10]   Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples [J].
Chamsaz, Mahmoud ;
Atarodi, Atefe ;
Eftekhari, Mohammad ;
Asadpour, Saeid ;
Adibi, Mina .
JOURNAL OF ADVANCED RESEARCH, 2013, 4 (01) :35-41