COMPARATIVE EVALUATION OF THE CORROSION RESISTANCE OF SOME CO-CR ALLOYS USED IN METAL-CERAMIC TECHNOLOGY

被引:0
作者
Laurentiu, Dragus [1 ]
Mihaela, Buciumeanu [2 ]
Valentin, Amortila [2 ]
Monica, Comaneanu Raluca [3 ]
Elena, Ungureanu [4 ]
Violeta, Hancu [3 ]
机构
[1] Dunarea de Jos Univ Galati, Fac Med & Pharm, Dept Dent, Galati, Romania
[2] Dunarea de Jos Univ Galati, Fac Engn, Dept Mech Engn, Galati, Romania
[3] Titu Maiorescu Univ Bucharest, Fac Dent, Dept Dent, Bucharest 60042, Romania
[4] Univ Politehn Bucuresti, Fac Mat Sci & Engn, Bucharest 60042, Romania
来源
ROMANIAN JOURNAL OF ORAL REHABILITATION | 2022年 / 14卷 / 02期
关键词
corrosion; dental alloys; artificial saliva; NI-CR; COMPLICATION RATES; SURFACE CONDITION; IN-VITRO; SURVIVAL; BEHAVIOR;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Co-Cr alloys are still used in metal-ceramic technology on the large scale. The purpose of this study was to provide a comparative analysis of the corrosion resistance by the polarization resistance technique of two Co-Cr-based alloys (codified Co-Cr- P and Co-Cr-PW) produced by the same manufacturer, which have a minor variation in chemical composition. Corrosion tests were performed at a temperature of 37 +/- 0.5 degrees C in a bath with heating and recirculation, in artificial saliva (SA) Carter Brugirard at pH = 7.58. Both tested alloys showed an increased corrosion resistance when immersed in artificial saliva, proving a good corrosion resistance and therefore a good biocompatibility. The Co-Cr-P test showed superior electrochemical values and, implicitly, higher corrosion resistance.
引用
收藏
页码:140 / 152
页数:13
相关论文
共 48 条
[1]  
Ahmadzadeh Asadollah, 2019, Dent Res J (Isfahan), V16, P298
[2]   Evaluation of the Behavior of Two CAD/CAM Fiber-Reinforced Composite Dental Materials by Immersion Tests [J].
Bechir, Farah ;
Bataga, Simona Maria ;
Tohati, Adrian ;
Ungureanu, Elena ;
Cotrut, Cosmin Mihai ;
Bechir, Edwin Sever ;
Suciu, Mircea ;
Vranceanu, Diana Maria .
MATERIALS, 2021, 14 (23)
[3]   Experimental Study Regarding the Behavior at Different pH of Two Types of Co-Cr Alloys Used for Prosthetic Restorations [J].
Bechir, Farah ;
Bataga, Simona Maria ;
Ungureanu, Elena ;
Vranceanu, Diana Maria ;
Pacurar, Mariana ;
Bechir, Edwin Sever ;
Cotrut, Cosmin Mihai .
MATERIALS, 2021, 14 (16)
[4]   Enhancement of the biocompatibility by surface nitriding of a low-modulus titanium alloy for dental implant applications [J].
Bedouin, Yvan ;
Gordin, Doina-Margareta ;
Pellen-Mussi, Pascal ;
Perez, Fabienne ;
Tricot-Doleux, Sylvie ;
Vasilescu, Cora ;
Drob, Silviu Iulian ;
Chauvel-Lebret, Dominique ;
Gloriant, Thierry .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2019, 107 (05) :1483-1490
[5]   Castability and resistance of ceramometal bonding in Ni-Cr and Ni-Cr-Be alloys [J].
Bezzon, OL ;
Ribeiro, RF ;
Rollo, JMDA ;
Crosara, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (03) :299-304
[6]  
Bita AI, 2016, UNIV POLITEH BUCHAR, V78, P173
[7]  
Bolcu D, 2009, MATER PLAST, V46, P206
[8]  
Cetik Sibel, 2018, J Dent (Tehran), V15, P137
[9]   Zirconia implant abutments supporting single all-ceramic crowns in anterior and premolar regions: A six-year retrospective study [J].
Chen, Jo-Yu ;
Pan, Yu-Hwa .
BIOMEDICAL JOURNAL, 2019, 42 (05) :358-364
[10]   Adhesive-Ceramic Interface Behavior in Dental Restorations. FEM Study and SEM Investigation [J].
Chirca, Otilia ;
Biclesanu, Cornelia ;
Florescu, Anamaria ;
Stoia, Dan Ioan ;
Pangica, Anna Maria ;
Burcea, Alexandru ;
Vasilescu, Marius ;
Antoniac, Iulian Vasile .
MATERIALS, 2021, 14 (17)