OPTIMIZING SENSITIVITY OF ULTRASOUND CONTRAST-ENHANCED SUPER-RESOLUTION IMAGING BY TAILORING SIZE DISTRIBUTION OF MICROBUBBLE CONTRAST AGENT

被引:38
作者
Lin, Fanglue
Tsuruta, James K.
Rojas, Juan D.
Dayton, Paul A.
机构
[1] Univ North Carolina Chapel Hill, Joint Dept Biomed Engn, Chapel Hill, NC USA
[2] North Carolina State Univ, Chapel Hill, NC USA
基金
美国国家卫生研究院;
关键词
Super resolution; Microbubble contrast agent; Sensitivity; Size distribution; IMPROVING SENSITIVITY; DIFFRACTION-LIMIT; IN-VIVO; DISSOLUTION; MICROSCOPY;
D O I
10.1016/j.ultrasmedbio.2017.05.014
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound contrast-enhanced super-resolution imaging has recently attracted attention because of its extraordinary ability to image vascular features much smaller than the ultrasound diffraction limit. This method requires sensitive detection of separable microbubble events despite a noisy tissue background to indicate the microvasculature, and any approach that could improve the sensitivity of the ultrasound system to individual microbubbles would be highly beneficial. In this study, we evaluated the effect of varying microbubble size on super-resolution imaging sensitivity. Microbubble preparations were size sorted into different mean diameters and then were imaged at equal concentrations. Commercially manufactured Definity and Optison were also imaged for comparison. Both in vitro experiments in phantom vessels and in vivo experiments imaging rat tumors revealed that the sensitivity of contrast-enhanced super-resolution imaging can be improved by using microbubbles with a larger diameter. (C) 2017 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2488 / 2493
页数:6
相关论文
共 23 条
[1]   Imaging intracellular fluorescent proteins at nanometer resolution [J].
Betzig, Eric ;
Patterson, George H. ;
Sougrat, Rachid ;
Lindwasser, O. Wolf ;
Olenych, Scott ;
Bonifacino, Juan S. ;
Davidson, Michael W. ;
Lippincott-Schwartz, Jennifer ;
Hess, Harald F. .
SCIENCE, 2006, 313 (5793) :1642-1645
[2]   Dissolution behavior of lipid monolayer-coated, air-filled microbubbles: Effect of lipid hydrophobic chain length [J].
Borden, MA ;
Longo, ML .
LANGMUIR, 2002, 18 (24) :9225-9233
[3]   In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles [J].
Christensen-Jeffries, Kirsten ;
Browning, Richard J. ;
Tang, Meng-Xing ;
Dunsby, Christopher ;
Eckersley, Robert J. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) :433-440
[4]  
Dayton, 2016, P 2016 IEEE INT ULTR, P1, DOI DOI 10.1109/TTE.2016.2630922
[5]   Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity [J].
Demene, Charlie ;
Deffieux, Thomas ;
Pernot, Mathieu ;
Osmanski, Bruno-Felix ;
Biran, Valerie ;
Gennisson, Jean-Luc ;
Sieu, Lim-Anna ;
Bergel, Antoine ;
Franqui, Stephanie ;
Correas, Jean-Michel ;
Cohen, Ivan ;
Baud, Olivier ;
Tanter, Mickael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) :2271-2285
[6]   Sono-activated ultrasound localization microscopy [J].
Desailly, Yann ;
Couture, Olivier ;
Fink, Mathias ;
Tanter, Mickael .
APPLIED PHYSICS LETTERS, 2013, 103 (17)
[7]   Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging [J].
Errico, Claudia ;
Pierre, Juliette ;
Pezet, Sophie ;
Desailly, Yann ;
Lenkei, Zsolt ;
Couture, Olivier ;
Tanter, Mickael .
NATURE, 2015, 527 (7579) :499-+
[8]   Quantitative Volumetric Perfusion Mapping of the Microvasculature Using Contrast Ultrasound [J].
Feingold, Steven ;
Gessner, Ryan ;
Guracar, Ismayil M. ;
Dayton, Paul A. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (10) :669-674
[9]   Microbubble size isolation by differential centrifugation [J].
Feshitan, Jameel A. ;
Chen, Cherry C. ;
Kwan, James J. ;
Borden, Mark A. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 329 (02) :316-324
[10]  
GE Healthcare, 2012, OPT PRESC INF