The beat-to-beat relationship between pulse transit time and systolic blood pressure

被引:0
|
作者
Poon, Carmen C. Y. [1 ]
Zhang, Yuan-Ting [1 ]
Wong, George [2 ]
Poon, Wai Sang [2 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Joint Res Ctr Biomed Engn JCBME, Hong Kong, Hong Kong, Peoples R China
[2] Prince Wales Hosp, Div Neurosurg, Hong Hom, Hong Kong, Peoples R China
关键词
wearable medical devices; cuffless blood pressure measurement; pulse transit time; m-health;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-invasive measurement of beat-to-beat arterial blood pressure (BP) is an interesting but currently unsolved topic in long-term physiological monitoring by wearable devices and body sensor networks. Although it is suggested that pulse transit time (PTT) is related to and can be used to estimate BP, few studies showed how their relationship changes over time. This study reported the beat-to-beat correlation between PTT and invasive BP of short segments for 4 subjects during an 8-hour period. The results of the study found that the median correlation of beat-to-beat PTT and invasive BP decreased from -0.73 to -0.63 when the number of consecutive bents used to calculate the correlation increased from 15 to 360, suggesting that PTT-based techniques may need frequent calibration in order to estimate beat-to-beat BP.
引用
收藏
页码:357 / +
页数:2
相关论文
共 50 条
  • [21] Validation of New and Existing Decision Rules for the Estimation of Beat-to-Beat Pulse Transit Time
    Zhou, Xiaolin
    Peng, Rongchao
    Ding, Hongxia
    Zhang, Ningling
    Li, Pan
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [22] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Arash Abiri
    En-Fan Chou
    Weining Shen
    Mark J. Fisher
    Michelle Khine
    Scientific Reports, 13
  • [23] Beat-to-beat Systolic as Well as Diastolic Blood Pressure Variability is High in Atrial Fibrillation
    Olbers, Joakim
    Gille, Adam
    Ostergren, Jan
    Ljungman, Petter
    Rosenqvist, Marten
    Witt, Nils
    CIRCULATION, 2015, 132
  • [24] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Abiri, Arash
    Chou, En-Fan
    Shen, Weining
    Fisher, Mark J.
    Khine, Michelle
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [25] Two different sensor locations for the beat-to-beat measurement of continuous noninvasive blood pressure by determining pulse wave velocity and transit time: Are they equivalent?
    Brem, MH
    Boll, R
    Lutter, N
    JOURNAL OF HYPERTENSION, 2005, 23 : S27 - S27
  • [26] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [27] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552
  • [28] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [29] Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data
    Lin, Yu-Ting
    Lo, Yu-Lun
    Lin, Chen-Yun
    Frasch, Martin G.
    Wu, Hau-Tieng
    PLOS ONE, 2019, 14 (09):
  • [30] Systolic and diastolic blood pressure display a linear relationship on a beat-to-beat basis, differently influenced by breathing patterns and neck suction
    Gavish, B.
    Alter, A.
    Caldara, G.
    Giglio, A.
    Bilo, G.
    Boarin, S.
    Mancia, G.
    Parati, G.
    JOURNAL OF HYPERTENSION, 2008, 26 : S482 - S482