Insertion of linear 8.4μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

被引:129
|
作者
Patel, Paras R. [1 ]
Na, Kyounghwan [2 ]
Zhang, Huanan [3 ]
Kozai, Takashi D. Y. [4 ,7 ,8 ]
Kotov, Nicholas A. [1 ,5 ,6 ]
Yoon, Euisik [1 ,2 ]
Chestek, Cynthia A. [1 ,2 ]
机构
[1] Univ Michigan, Coll Engn, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Coll Engn, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Coll Engn, Dept Chem Engn, Ann Arbor, MI 48109 USA
[4] Univ Pittsburgh, Coll Engn, Dept Bioengn, Pittsburgh, PA 15260 USA
[5] Univ Michigan, Coll Engn, Dept Mat Sci & Engn, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Coll Engn, Dept Macromol Sci & Engn, Ann Arbor, MI 48109 USA
[7] Univ Pittsburgh, Ctr Neural Basis Cognit, Pittsburgh, PA 15260 USA
[8] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15260 USA
基金
美国国家科学基金会;
关键词
carbon electrodes; neural probes; microelectrodes; MEAs; BRAIN-MACHINE INTERFACE; MICROELECTRODE ARRAYS; NEURAL PROBES; IN-VIVO; DOPAMINE RELEASE; TISSUE-RESPONSE; BIOCOMPATIBILITY; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); PERFORMANCE; SURFACES;
D O I
10.1088/1741-2560/12/4/046009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Single carbon fiber electrodes (d = 8.4 mu m) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with similar to 150 mu m pitch. Approach. Two approaches were tested for the insertion of carbon fiber arrays. The first method used a poly(ethylene glycol) (PEG) coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 mu m-1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 mu m apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results. Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in five rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in three acute rat surgeries. In one of those surgeries a stacked device with three layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance. From these studies we have found that carbon fibers spaced at similar to 150 mu m readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response.
引用
收藏
页数:18
相关论文
共 18 条
  • [1] Automated assembly of high-density carbon fiber electrode arrays for single unit electrophysiological recordings
    Dong, Tianshu
    Chen, Lei
    Patel, Paras R.
    Richie, Julianna M.
    Chestek, Cynthia A.
    Shih, Albert J.
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (03)
  • [2] Single 5 μm diameter needle electrode block modules for unit recordings in vivo
    H. Sawahata
    S. Yamagiwa
    A. Moriya
    T. Dong
    H. Oi
    Y. Ando
    R. Numano
    M. Ishida
    K. Koida
    T. Kawano
    Scientific Reports, 6
  • [3] Single 5 μm diameter needle electrode block modules for unit recordings in vivo
    Sawahata, H.
    Yamagiwa, S.
    Moriya, A.
    Dong, T.
    Oi, H.
    Ando, Y.
    Numano, R.
    Ishida, M.
    Koida, K.
    Kawano, T.
    SCIENTIFIC REPORTS, 2016, 6
  • [4] 64-Channel Carbon Fiber Electrode Arrays for Chronic Electrophysiology
    Guitchounts, Grigori
    Cox, David
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] 64-Channel Carbon Fiber Electrode Arrays for Chronic Electrophysiology
    Grigori Guitchounts
    David Cox
    Scientific Reports, 10
  • [6] Multiple single-unit recordings from the CNS using thin-film electrode arrays
    Carter, Randy R.
    Houk, James C.
    IEEE Transactions on Rehabilitation Engineering, 1993, 3 (02): : 175 - 184
  • [7] In Vivo Dopamine Detection and Single Unit Recordings Using Intracortical Glassy Carbon Microelectrode Arrays
    Castagnola E.
    Winchester Vahidi N.
    Nimbalkar S.
    Rudraraju S.
    Thielk M.
    Zucchini E.
    Cea C.
    Carli S.
    Gentner T.Q.
    Ricci D.
    Fadiga L.
    Kassegne S.
    MRS Advances, 2018, 3 (29) : 1629 - 1634
  • [8] Comparison of single-fiber and macro electrode recordings: Relationship to motor unit action potential duration
    Dumitru, D
    King, JC
    Nandedkar, SD
    MUSCLE & NERVE, 1997, 20 (11) : 1381 - 1388
  • [9] Characterization of a 32 μm diameter carbon fiber electrode for in vivo fast-scan cyclic voltammetry
    Chadchankar, Heramb
    Yavich, Leonid
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 211 (02) : 218 - 226
  • [10] Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays
    Farina, D
    Muhammad, W
    Fortunato, E
    Meste, O
    Merletti, R
    Rix, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (02) : 225 - 236