Simulation of Ultrasound RF Signals Backscattered from a 3D Model of Pulsating Artery Surrounded by Tissue

被引:1
作者
Makunaite, Monika [1 ]
Jurkonis, Rytis [1 ]
Lukosevicius, Arunas [1 ]
Baranauskas, Mindaugas [1 ]
机构
[1] Kaunas Univ Technol, Inst Biomed Engn, K Barsausko Str 59-455, LT-51423 Kaunas, Lithuania
关键词
carotid artery; ultrasound; scatterers; motion simulation; Field II; PRIMARY PREVENTION; SHEAR STRAIN; CORONARY; DISEASE; MOTION; ATHEROSCLEROSIS; MOVEMENTS; DIAMETER; HEALTHY; WOMEN;
D O I
10.3390/diagnostics12020232
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial stiffness is an independent predictor of cardiovascular events. The motion of arterial tissues during the cardiac cycle is important as a mechanical deformation representing vessel elasticity and is related to arterial stiffness. In addition, arterial pulsation is the main source of endogenous tissue micro-motions currently being studied for tissue elastography. Methods based on artery motion detection are not applied in clinical practice these days, because they must be carefully investigated in silico and in vitro before wide usage in vivo. The purpose of this paper is to propose a dynamic 3D artery model capable of reproducing the biomechanical behavior of human blood vessels surrounded by elastic tissue for endogenous deformation elastography developments and feasibility studies. The framework is based on a 3D model of a pulsating artery surrounded by tissue and simulation of linear scanning by Field II software to generate realistic dynamic RF signals and B-mode ultrasound image sequential data. The model is defined by a spatial distribution of motions, having patient-specific slopes of radial and longitudinal motion components of the artery wall and surrounding tissues. It allows for simulating the quantified mechanical micro-motions in the volume of the model. Acceptable simulation errors calculated between modeled motion patterns and those estimated from simulated RF signals and B-scan images show that this approach is suitable for the development and validation of elastography algorithms based on motion detection.
引用
收藏
页数:21
相关论文
共 50 条
[31]   Development and evaluation of a semi-automatic 3D segmentation technique of the carotid arteries from 3D ultrasound images [J].
Gill, JD ;
Ladak, HM ;
Steinman, DA ;
Fenster, A .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :214-221
[32]   A Simple Method for 3D Thyroid Reconstruction from 2D Ultrasound Slices [J].
Ciora, Radu Adrian ;
Neamtu, Bogdan ;
Sofariu, Ciprian ;
Dospinescu, Cristina ;
Barbu, Andreea ;
Banciu, Daniel Dumitriu .
2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
[33]   Three Dimensional Level Set Based Semiautomatic Segmentation of Atherosclerotic Carotid Artery Wall Volume Using 3D Ultrasound Imaging [J].
Hossain, Md Murad ;
AlMuhanna, Khalid ;
Zhao, Limin ;
Lal, Brajesh K. ;
Sikdar, Siddhartha .
MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
[34]   Tools for an ultrasound based 3D bone model reconstruction, registration and visualization system [J].
Goncalves, Paulo Jorge Sequeira ;
Fernandes, Joaquim Moises .
EUROMEDIA '2008, 2008, :114-+
[35]   3D Deformable Organ Model Based Liver Motion Tracking in Ultrasound Videos [J].
Kim, Jung-Bae ;
Hwang, Youngkyoo ;
Oh, Young-Taek ;
Bang, Won-Chul ;
Lee, Heesae ;
Kim, James D. K. ;
Kim, ChangYeong .
MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
[36]   The effect of low intensity pulsed ultrasound in a 3D ex vivo orthodontic model [J].
El-Bialy, T. ;
Lam, B. ;
Aldaghreer, S. ;
Sloan, A. J. .
JOURNAL OF DENTISTRY, 2011, 39 (10) :693-699
[37]   Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts [J].
Schneider, Robert J. ;
Perrin, Douglas P. ;
Vasilyev, Nikolay V. ;
Marx, Gerald R. ;
del Nido, Pedro J. ;
Howe, Robert D. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (09) :1676-1687
[38]   Evaluation of algorithms for segmentation of the prostate boundary from 3D ultrasound images [J].
Ladak, HM ;
Ding, MY ;
Wang, YQ ;
Hu, N ;
Downey, DB ;
Fenster, A .
MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 :1403-1410
[39]   Functional Assessment of Stenotic Coronary Artery in 3D Geometric Reconstruction From Fusion of Intravascular Ultrasound and X-Ray Angiography [J].
Wang, Xiaoqing ;
Peng, Changnong ;
Liu, Xin ;
Pan, Zhigeng .
IEEE ACCESS, 2018, 6 :53330-53341
[40]   A validated 3D microstructure-based constitutive model of coronary artery adventitia [J].
Chen, Huan ;
Guo, Xiaomei ;
Luo, Tong ;
Kassab, Ghassan S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (01) :333-342