Simulation of Ultrasound RF Signals Backscattered from a 3D Model of Pulsating Artery Surrounded by Tissue

被引:1
作者
Makunaite, Monika [1 ]
Jurkonis, Rytis [1 ]
Lukosevicius, Arunas [1 ]
Baranauskas, Mindaugas [1 ]
机构
[1] Kaunas Univ Technol, Inst Biomed Engn, K Barsausko Str 59-455, LT-51423 Kaunas, Lithuania
关键词
carotid artery; ultrasound; scatterers; motion simulation; Field II; PRIMARY PREVENTION; SHEAR STRAIN; CORONARY; DISEASE; MOTION; ATHEROSCLEROSIS; MOVEMENTS; DIAMETER; HEALTHY; WOMEN;
D O I
10.3390/diagnostics12020232
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial stiffness is an independent predictor of cardiovascular events. The motion of arterial tissues during the cardiac cycle is important as a mechanical deformation representing vessel elasticity and is related to arterial stiffness. In addition, arterial pulsation is the main source of endogenous tissue micro-motions currently being studied for tissue elastography. Methods based on artery motion detection are not applied in clinical practice these days, because they must be carefully investigated in silico and in vitro before wide usage in vivo. The purpose of this paper is to propose a dynamic 3D artery model capable of reproducing the biomechanical behavior of human blood vessels surrounded by elastic tissue for endogenous deformation elastography developments and feasibility studies. The framework is based on a 3D model of a pulsating artery surrounded by tissue and simulation of linear scanning by Field II software to generate realistic dynamic RF signals and B-mode ultrasound image sequential data. The model is defined by a spatial distribution of motions, having patient-specific slopes of radial and longitudinal motion components of the artery wall and surrounding tissues. It allows for simulating the quantified mechanical micro-motions in the volume of the model. Acceptable simulation errors calculated between modeled motion patterns and those estimated from simulated RF signals and B-scan images show that this approach is suitable for the development and validation of elastography algorithms based on motion detection.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] SAFARI FROM VISUAL SIGNALS: RECOVERING VOLUMETRIC 3D SHAPES
    Agudo, Antonio
    2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, : 2495 - 2499
  • [22] 2-D Versus 3-D Cross-Correlation-Based Radial and Circumferential Strain Estimation Using Multiplane 2-D Ultrafast Ultrasound in a 3-D Atherosclerotic Carotid Artery Model
    Fekkes, Stein
    Swillens, Abigail E. S.
    Hansen, Hendrik H. G.
    Saris, Anne E. C. M.
    Nillesen, Maartje M.
    Iannaccone, Francesco
    Segers, Patrick
    de Korte, Chris L.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (10) : 1543 - 1553
  • [23] Direct surface extraction from 3D freehand ultrasound images
    Zhang, Y
    Rohling, R
    Pai, DK
    VIS 2002: IEEE VISUALIZATION 2002, PROCEEDINGS, 2002, : 45 - 52
  • [24] Automated extraction of the LV from 3D cardiac ultrasound scans
    Ashton, EA
    Phillips, D
    Parker, KJ
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING '96, 1996, 2727 : 423 - 429
  • [25] 3D segmentation of kidney tumors from freehand 2D ultrasound
    Ahmad, Anis
    Cool, Derek
    Chew, Ben H.
    Pautler, Stephen E.
    Peters, Terry M.
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [26] Reverberation Noise Suppression in Ultrasound Channel Signals Using a 3D Fully Convolutional Neural Network
    Brickson, Leandra L.
    Hyun, Dongwoon
    Jakovljevic, Marko
    Dahl, Jeremy J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (04) : 1184 - 1195
  • [27] Towards 3D ultrasound imaging of the carotid artery using a programmable and tileable matrix array
    Kruizinga, Pieter
    Kang, Eunchul
    Shabanimotlagh, Maysam
    Ding, Qing
    Noothout, Emile
    Chang, Zu Yao
    Vos, Hendrick J.
    Bosch, Johannes G.
    Verweij, Martin D.
    Pertijs, Michiel A. P.
    de Chang, Nico
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [28] Automated 3D Model Reconstruction from Photographs
    Bourke, Paul
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON VIRTUAL SYSTEMS AND MULTIMEDIA (VSMM), 2014, : 21 - 24
  • [29] Intelligent Carpet: Inferring 3D Human Pose from Tactile Signals
    Luo, Yiyue
    Li, Yunzhu
    Foshey, Michael
    Shou, Wan
    Sharma, Pratyusha
    Palacios, Tomas
    Torralba, Antonio
    Matusik, Wojciech
    2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, CVPR 2021, 2021, : 11250 - 11260
  • [30] Development and evaluation of a semi-automatic 3D segmentation technique of the carotid arteries from 3D ultrasound images
    Gill, JD
    Ladak, HM
    Steinman, DA
    Fenster, A
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 214 - 221