A novel low-cost approach for navigated transcranial magnetic stimulation

被引:15
作者
Rodseth, Jakob [1 ]
Washabaugh, Edward P. [1 ,3 ]
Krishnan, Chandramouli [1 ,2 ,3 ]
机构
[1] Univ Michigan, Med Sch, Dept Phys Med & Rehabil, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Kinesiol, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Frameless stereotaxic system; brain stimulation; neuronavigation; coil tracking; motor mapping; co-registration; MOTOR-EVOKED-POTENTIALS; VOLUNTARY ACTIVATION; ISCHEMIC-STROKE; COIL PLACEMENT; TMS; EXCITABILITY; RECONSTRUCTION; INHIBITION; RECOVERY; FMRI;
D O I
10.3233/RNN-170751
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Transcranial magnetic stimulation (TMS) is commonly used for assessing or modulating brain excitability. However, the credibility of TMS outcomes depends on accurate and reliable coil placement during stimulation. Navigated TMS systems can address this issue, but these systems are expensive for routine use in clinical and research environments. Objective: The purpose of this study was to provide a high-quality open source framework for navigated TMS and test its reliability and accuracy using standard TMS procedures. Methods: A navigated TMS system was created using a low-cost 3D camera system (OptiTrack Trio), which communicates with our free and open source software environment programmed using the Unity 3D gaming engine. The environment is user friendly and has functions to allow for a variety of stimulation procedures (e.g., head and coil co-registration, multiple hotspot/grid tracking, intuitive matching, and data logging). The system was then validated using a static mockup of a TMS session. The clinical utility was also evaluated by assessing the repeatability and operator accuracy when collecting motor evoked potential (MEP) data from human subjects. Results: The system was highly reliable and improved coil placement accuracy (position error = 1.2 mm and orientation error = 0.3.) as well as the quality and consistency (ICC > 0.95) of MEPs recorded during TMS. Conclusion: These results indicate that the proposed system is a viable tool for reliable coil placement during TMS procedures, and can improve accuracy in locating the coil over a desired hotspot both within and between sessions.
引用
收藏
页码:601 / 609
页数:9
相关论文
共 50 条
  • [41] Repeatability of functional anisotropy in navigated transcranial magnetic stimulation - coil-orientation versus response
    Kallioniemi, Elisa
    Kononen, Mervi
    Julkunen, Petro
    NEUROREPORT, 2015, 26 (09) : 515 - 521
  • [42] Navigated Transcranial Magnetic Stimulation-Guided Resection of a Left Parietal Tumor: Case Report
    Coburger, J.
    Musahl, C.
    Weissbach, C.
    Bittl, M.
    MINIMALLY INVASIVE NEUROSURGERY, 2011, 54 (01) : 38 - 40
  • [43] Mapping Motor Neuroplasticity after Successful Surgical Brachial Plexus Reconstruction Using Navigated Transcranial Magnetic Stimulation (nTMS)
    Durner, Gregor
    Ulrich, Ina
    Gerst, Alexandra
    Becker, Ralf
    Wirtz, Christian Rainer
    Antoniadis, Gregor
    Pedro, Maria Teresa
    Pala, Andrej
    NEUROLOGY INTERNATIONAL, 2024, 16 (01): : 239 - 252
  • [44] Enhanced motor function and its neurophysiological correlates after navigated low-frequency repetitive transcranial magnetic stimulation over the contralesional motor cortex in stroke
    Bashir, Shahid
    Vernet, Marine
    Najib, Umer
    Perez, Jennifer
    Alonso-Alonso, Miguel
    Knobel, Mark
    Yoo, Woo-Kyoung
    Edwards, Dylan
    Pascual-Leone, Alvaro
    RESTORATIVE NEUROLOGY AND NEUROSCIENCE, 2016, 34 (04) : 677 - 689
  • [45] Co-registration of magnetic resonance spectroscopy and transcranial magnetic stimulation
    Hone-Blanchet, Antoine
    Salas, Rachel E.
    Celnik, Pablo
    Kalloo, Aadi
    Schar, Michael
    Puts, Nicolaas A. J.
    Harris, Ashley D.
    Barkerd, Peter B.
    Fecteau, Shirley
    Earley, Christopher J.
    Allen, Richard P.
    Edden, Richard A.
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 242 : 52 - 57
  • [46] Navigated Transcranial Magnetic Stimulation in Patient with Cranioplasty in Situ: Safe and Accurate Procedure
    Lavrador, Jose Pedro
    Kandeel, Hussein
    Patel, Sabina
    Jung, Josephine
    Acharya, Shami
    Giamouriadis, Anastasios
    Ashkan, Keyoumars
    Bhangoo, Ranjeev
    Vergani, Francesco
    WORLD NEUROSURGERY, 2019, 122 : 176 - 179
  • [47] Comparing navigated transcranial magnetic stimulation mapping and "gold standard" direct cortical stimulation mapping in neurosurgery: a systematic review
    Jeltema, Hanne-Rinck
    Ohlerth, Ann-Katrin
    de Wit, Aranka
    Wagemakers, Michiel
    Rofes, Adria
    Bastiaanse, Roelien
    Drost, Gea
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 1903 - 1920
  • [48] Study Design for Navigated Repetitive Transcranial Magnetic Stimulation for Speech Cortical Mapping
    Lioumis, Pantelis
    Autti, Salla
    Wilenius, Juha
    Vaalto, Selja
    Lehtinen, Henri
    Laakso, Aki
    Kirveskari, Erika
    Makela, Jyrki P.
    Liljestrom, Mia
    Renvall, Hanna
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (193):
  • [49] Safety and tolerability of navigated transcranial magnetic stimulation in a tumor patient with no bone flap
    Kandeel, Hussein
    Mirza, Asfand
    Lavrador, Jose Pedro
    Patel, Sabina
    Gullan, Richard
    Bhangoo, Ranjeev
    Vergani, Francesco
    Ashkan, Keyoumars
    CLINICAL NEUROPHYSIOLOGY, 2020, 131 (02) : 592 - 593
  • [50] Non-invasive Mapping of Face Processing by Navigated Transcranial Magnetic Stimulation
    Maurer, Stefanie
    Giglhuber, Katrin
    Sollmann, Nico
    Kelm, Anna
    Ille, Sebastian
    Hauck, Theresa
    Tanigawa, Noriko
    Ringel, Florian
    Boeckh-Behrens, Tobias
    Meyer, Bernhard
    Krieg, Sandro M.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11