Trabecular metal versus non-trabecular metal acetabular components for acetabular revision surgery: A systematic review and meta-analysis

被引:13
|
作者
Shen, Xianyue [1 ]
Qin, Yanguo [1 ]
Li, Yang [2 ]
Tang, Xiongfeng [1 ]
Xiao, Jianlin [2 ]
机构
[1] Second Hosp Jilin Univ, Dept Orthoped, Changchun 130041, Jilin, Peoples R China
[2] Jilin Univ, China Japan Union Hosp, Dept Orthoped, Changchun 130033, Jilin, Peoples R China
基金
中国博士后科学基金;
关键词
Total hip arthroplasty; Acetabular revision; Trabecular metal; TOTAL HIP-ARTHROPLASTY; POROUS TANTALUM SHELLS; RETROSPECTIVE COHORT; CUPS; RISK; SCAFFOLDS; SURVIVAL; REDUCE;
D O I
10.1016/j.ijsu.2022.106597
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The objective of this study was to compare cup survival and the incidence of adverse events associated with the use of trabecular metal (TM) and non-TM cups for acetabular revision surgery.& nbsp;Methods: The MEDLINE, EMBASE, and Cochrane Library databases were searched for comparative studies that reported cup survival and the incidence of adverse events associated with the use of TM and non-TM cups for acetabular revision surgery. Primary outcomes included cup survival, aseptic loosening, dislocation, and infection.& nbsp;Results: The meta-analysis included 6 studies that involved 13,864 total hip arthroplasty (THA) revisions who underwent acetabular revision surgery with TM (n = 5,619) or non-TM (n = 8,245) cups. The meta-analysis demonstrated no significant difference in cup survival using re-revision for any reason or aseptic loosening as the endpoint following acetabular revision surgery with TM or non-TM cups (HR = 0.96; [95% CI, 0.84-1.09]; HR = 1.29; [95% CI, 0.70-2.38]). Pooled data indicated that the overall incidence of adverse events for TM or non-TM cups was 6.8% (382/5,289) and 9.0% (725/8,083), respectively, and not significantly different (OR = 0.91; [95% CI, 0.80-1.04]). The incidence of aseptic loosening and infection were significantly lower (OR = 0.75; [95% CI, 0.58-0.96]; OR = 0.70; [95% CI, 0.54-0.90]) and the incidence of dislocation was significantly higher (OR = 1.53; [95% CI, 1.22-1.91]) for TM compared to non-TM cups.& nbsp;Conclusion: This review was the first to use reconstructed time-to-event data to find that there was no difference in survival of TM and non-TM cups in acetabular revision surgery. Overall, fewer adverse events were associated with the use of TM compared to non-TM cups, but the difference was not significant. The incidence of aseptic loosening and infection were significantly lower and the incidence of dislocation was significantly higher for TM compared to non-TM cups. This information is expected to guide orthopedic surgeons in the selection of appropriate acetabular components for THA revision.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Serum metal ion levels in modular dual mobility acetabular components: A systematic review
    Gkiatas, Ioannis
    Sharma, Abhinav K.
    Greenberg, Alexander
    Duncan, Stephen T.
    Chalmers, Brian P.
    Sculco, Peter K.
    JOURNAL OF ORTHOPAEDICS, 2020, 21 : 432 - 437
  • [32] Cemented acetabular components combined with trabecular metal augments provide excellent long-term survivorship for severe acetabular bone loss
    Garala, Kanai
    Remtulla, Mohammed Abbas
    Verma, Raghav
    Lawrence, Trevor
    HIP INTERNATIONAL, 2023, 33 (05) : 833 - 838
  • [33] Rekonstruktion größerer Pfannendefekte mit metallischen Augmentaten – Trabecular Metal TechnologyReconstruction of Large Acetabular Defects Using Trabecular Metal Augments
    Olaf Hasart
    Carsten Perka
    Rex Lehnigk
    Stephan Tohtz
    Operative Orthopädie und Traumatologie, 2010, 22 (3) : 268 - 277
  • [34] Clinical and radiological evaluation of modular trabecular metal acetabular cups Short-term results in 64 hips
    Simon, Jean-Pierre
    Bellemans, Johan
    ACTA ORTHOPAEDICA BELGICA, 2009, 75 (05): : 623 - 630
  • [35] Mid-term results of revision surgery using double-trabecular metal cups alone or combined with impaction bone grafting for complex acetabular defects
    Zhang, Xianghong
    Li, Zhihong
    Wang, Wanchun
    Liu, Tang
    Peng, Weiqiu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [36] A single centre study of 41 cases on the use of porous tantalum metal implants in acetabular revision surgery
    Theil, Christoph
    Schmidt-Braekling, Tom
    Gosheger, Georg
    Moellenbeck, Burkhard
    Schwarze, Jan
    Dieckmann, Ralf
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [37] Jumbo Bionic Trabecular Metal Acetabular Cups Improve Cup Stability During Acetabular Bone Defect Reconstruction: A Finite Element Analysis Study
    Jianlin Xiao
    Haowen Xue
    Zhihui Qian
    Shenghao Xu
    Xianyue Shen
    Zhuo Zhang
    Lei Ren
    Luquan Ren
    Journal of Bionic Engineering, 2023, 20 : 2814 - 2825
  • [38] Acetabular defect reconstruction in revision surgery of the hip. Autologous, homologous or metal?
    Gravius, S.
    Pagenstert, G.
    Weber, O.
    Kraska, N.
    Roehrig, H.
    Wirtz, D. C.
    ORTHOPADE, 2009, 38 (08): : 729 - +
  • [39] Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies
    Cho, Chan Hee
    Pijls, Bart G.
    Abrahams, John M.
    Roerink, Anne
    Katembwe, Raissa
    Baker, Andrew
    Solomon, Lucian B.
    Callary, Stuart A.
    ACTA ORTHOPAEDICA, 2023, 94 : 626 - 634
  • [40] Risk factors for acetabular fracture treatment failure: a systematic review and meta-analysis
    Esmaeili, Sina
    Shaker, Farhad
    Ghaseminejad-Raeini, Amirhossein
    Baghchi, Mohammadjavad
    Sajadi, Seyyed Mobin
    Shafiei, Seyyed Hossein
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)