Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations

被引:15
作者
Seoane, Fernando [1 ,2 ]
Abtahi, Shirin [3 ]
Abtahi, Farhad [2 ,4 ]
Ellegard, Lars [5 ]
Johannsson, Gudmundur [5 ]
Bosaeus, Ingvar [5 ]
Ward, Leigh C. [6 ]
机构
[1] Univ Boras, Fac Care Sci Work Life & Social Welfare, S-50190 Boras, Sweden
[2] Royal Inst Technol, Sch Technol & Hlth, S-14152 Huddinge, Sweden
[3] Karolinska Univ Hosp, Dept Oncol, S-17176 Stockholm, Sweden
[4] Karolinska Inst, Dept Clin Sci Intervent & Technol, S-14157 Stockholm, Sweden
[5] Univ Gothenburg, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Dept Clin Nutr, S-40530 Gothenburg, Sweden
[6] Univ Queensland, Sch Chem & Mol Biosci, Brisbane, AU 7072, Australia
关键词
BIOELECTRICAL-IMPEDANCE ANALYSIS; COLE PARAMETER-ESTIMATION; FAT-FREE MASS; FLUID VOLUME; HEMODIALYSIS-PATIENTS; WHOLE-BODY; VALIDATION; MODEL;
D O I
10.1155/2015/656323
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.
引用
收藏
页数:11
相关论文
共 44 条
  • [11] Cornish BH, 1996, EUR J CLIN NUTR, V50, P159
  • [12] The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients
    Davies, Simon J.
    Davenport, Andrew
    [J]. KIDNEY INTERNATIONAL, 2014, 86 (03) : 489 - 496
  • [13] Predicting body cell mass with bioimpedance by using theoretical methods: A technological review
    DeLorenzo, A
    Andreoli, A
    Matthie, J
    Withers, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) : 1542 - 1558
  • [14] MULTIFREQUENCY IMPEDANCE FOR THE PREDICTION OF EXTRACELLULAR WATER AND TOTAL-BODY WATER
    DEURENBERG, P
    TAGLIABUE, A
    SCHOUTEN, FJM
    [J]. BRITISH JOURNAL OF NUTRITION, 1995, 73 (03) : 349 - 358
  • [15] Deurenberg P, 1996, AM J CLIN NUTR, V64, P449
  • [16] Myo-inositol in depressive and healthy subjects determined by frontal 1H-magnetic resonance spectroscopy at 1.5 tesla
    Frey, R
    Metzler, D
    Fischer, P
    Heiden, A
    Scharfetter, J
    Moser, E
    Kasper, S
    [J]. JOURNAL OF PSYCHIATRIC RESEARCH, 1998, 32 (06) : 411 - 420
  • [17] Segmental bioelectrical impedance analysis in children aged 8-12y: 2. The assessment of regional body composition and muscle mass
    Fuller, NJ
    Fewtrell, MS
    Dewit, O
    Elia, M
    Wells, JCK
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2002, 26 (05) : 692 - 700
  • [18] Bioimpedance in the Assessment of Unilateral Lymphedema of a Limb: The Optimal Frequency
    Gaw, Richelle
    Box, Robyn
    Cornish, Bruce
    [J]. LYMPHATIC RESEARCH AND BIOLOGY, 2011, 9 (02) : 93 - 99
  • [19] Bioelectrical impedance analysis to estimate body composition in surgical and oncological patients: a systematic review
    Haverkort, E. B.
    Reijven, P. L. M.
    Binnekade, J. M.
    de van der Schuerent, M. A. E.
    Earthman, C. P.
    Gouma, D. J.
    de Haan, R. J.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 (01) : 3 - 13
  • [20] HEITMANN BL, 1990, INT J OBESITY, V14, P789