Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations

被引:15
作者
Seoane, Fernando [1 ,2 ]
Abtahi, Shirin [3 ]
Abtahi, Farhad [2 ,4 ]
Ellegard, Lars [5 ]
Johannsson, Gudmundur [5 ]
Bosaeus, Ingvar [5 ]
Ward, Leigh C. [6 ]
机构
[1] Univ Boras, Fac Care Sci Work Life & Social Welfare, S-50190 Boras, Sweden
[2] Royal Inst Technol, Sch Technol & Hlth, S-14152 Huddinge, Sweden
[3] Karolinska Univ Hosp, Dept Oncol, S-17176 Stockholm, Sweden
[4] Karolinska Inst, Dept Clin Sci Intervent & Technol, S-14157 Stockholm, Sweden
[5] Univ Gothenburg, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Dept Clin Nutr, S-40530 Gothenburg, Sweden
[6] Univ Queensland, Sch Chem & Mol Biosci, Brisbane, AU 7072, Australia
关键词
BIOELECTRICAL-IMPEDANCE ANALYSIS; COLE PARAMETER-ESTIMATION; FAT-FREE MASS; FLUID VOLUME; HEMODIALYSIS-PATIENTS; WHOLE-BODY; VALIDATION; MODEL;
D O I
10.1155/2015/656323
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.
引用
收藏
页数:11
相关论文
共 44 条
  • [1] ERROR MEASURES FOR GENERALIZING ABOUT FORECASTING METHODS - EMPIRICAL COMPARISONS
    ARMSTRONG, JS
    COLLOPY, F
    [J]. INTERNATIONAL JOURNAL OF FORECASTING, 1992, 8 (01) : 69 - 80
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Sources of error in bioimpedance spectroscopy
    Bolton, MP
    Ward, LC
    Khan, A
    Campbell, I
    Nightingale, P
    Dewit, O
    Elia, M
    [J]. PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) : 235 - 245
  • [4] BODY-COMPOSITION - PREDICTION OF NORMAL BODY POTASSIUM, BODY-WATER AND BODY-FAT IN ADULTS ON THE BASIS OF BODY HEIGHT, BODY-WEIGHT AND AGE
    BRUCE, A
    ANDERSSON, M
    ARVIDSSON, B
    ISAKSSON, B
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (05) : 461 - 473
  • [5] Robustness study of the different immittance spectra and frequency ranges in bioimpedance spectroscopy analysis for assessment of total body composition
    Buendia, R.
    Seoane, F.
    Bosaeus, I.
    Gil-Pita, R.
    Johannsson, G.
    Ellegard, L.
    Lindecrantz, K.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (07) : 1373 - 1395
  • [6] Buendia R., 2010, Journal of Physics: Conference Series, V224, DOI 10.1088/1742-6596/224/1/012126
  • [7] Experimental validation of a method for removing the capacitive leakage artifact from electrical bioimpedance spectroscopy measurements
    Buendia, R.
    Seoane, F.
    Gil-Pita, R.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (11)
  • [8] Buendia R, 2011, J ELECT BIOIMPEDANCE, V2, P6
  • [9] Influence of electrode mismatch on Cole parameter estimation from Total Right Side Electrical Bioimpedance Spectroscopy measurements
    Buendia, Ruben
    Bogonez-Franco, Paco
    Nescolarde, Lexa
    Seoane, Fernando
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) : 1024 - 1028
  • [10] Buéndía R, 2011, IEEE ENG MED BIO, P1843, DOI 10.1109/IEMBS.2011.6090524