Single UV excitation of Hoechst 33342 and propidium iodide for viability assessment of rhesus monkey spermatozoa using flow cytometry

被引:23
作者
Cai, K
Yang, J
Guan, M
Ji, W
Li, Y
Rens, W
机构
[1] Chinese Acad Sci, Kunming Inst Zool, Kunming 650223, Yunnan, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing, Peoples R China
[3] Yunnan Agr Univ, Coll Food Sci & Technol, Kunming, Yunnan, Peoples R China
[4] Univ Cambridge, Dept Clin Vet Med, Cambridge CB3 0ES, England
来源
ARCHIVES OF ANDROLOGY | 2005年 / 51卷 / 05期
关键词
flow cytometry; fluorescent probes; rhesus monkey; spermatozoa; viability;
D O I
10.1080/014850190924485
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
Many fluorescent probes excited by visible light have been used to assess sperm quality by flow cytometry. Developing a viability evaluation method using UV excited stains would be useful for multiparameter analysis of sperm function. This investigation was conducted to determine the efficacy of Hoechst 33342 (H342) and propidium iodide (PI) dual staining for evaluating rhesus monkey sperm viability through use of flow cytometry and excited by a single UV laser. The results showed that the live cells stained only with H342 strongly correlated with expected sperm viability, and flow cytometric analyses were highly correlated with fluorescence microscopic observation. Using H342/PI/SYBR-14 triple staining method, it was found that the live/dead sperm distributions were completely concordant in both H342/PI and SYBR-14/PI assays. In addition, this dual staining was extended with fluorescein isothiocyanate-conjugated peanut agglutinin (FITC-PNA) to simultaneously analyze viability and acrosome integrity of sperm cryopreserved using two different extenders, TTE and TEST, and indicated that TTE offered better Preservation of plasma and acrosome integrity than TEST Therefore, the H342/PI dual staining provides an accurate technique for evaluating viability of rhesus monkey sperm and should be valuable for multiparameter flow cytometric analysis of sperm function.
引用
收藏
页码:371 / 383
页数:13
相关论文
共 19 条
[1]   DEVELOPMENT OF PRE-IMPLANTATION EMBRYOS OF THE GOLDEN-HAMSTER IN A DEFINED CULTURE-MEDIUM [J].
BAVISTER, BD ;
LEIBFRIED, ML ;
LIEBERMAN, G .
BIOLOGY OF REPRODUCTION, 1983, 28 (01) :235-247
[2]   SINGLE UV EXCITATION OF HOECHST-33342 AND ETHIDIUM-BROMIDE FOR SIMULTANEOUS CELL-CYCLE ANALYSIS AND VIABILITY DETERMINATIONS ON IN-VITRO CULTURES OF MURINE B-LYMPHOCYTES [J].
BOLTZ, RC ;
FISCHER, PA ;
WICKER, LS ;
PETERSON, LB .
CYTOMETRY, 1994, 15 (01) :28-34
[3]   ASSESSMENT OF SPERMATOZOAL FUNCTION USING DUAL FLUORESCENT STAINING AND FLOW CYTOMETRIC ANALYSES [J].
GARNER, DL ;
PINKEL, D ;
JOHNSON, LA ;
PACE, MM .
BIOLOGY OF REPRODUCTION, 1986, 34 (01) :127-138
[4]   Porcine sperm viability, oocyte fertilization and embryo development after staining spermatozoa with SYBR-14 [J].
Garner, DL ;
Dobrinsky, JR ;
Welch, GR ;
Johnson, LA .
THERIOGENOLOGY, 1996, 45 (06) :1103-1112
[5]  
GARNER DL, 1994, J ANDROL, V15, P620
[6]   VIABILITY ASSESSMENT OF MAMMALIAN SPERM USING SYBR-14 AND PROPIDIUM IODIDE [J].
GARNER, DL ;
JOHNSON, LA .
BIOLOGY OF REPRODUCTION, 1995, 53 (02) :276-284
[7]   ANALYSIS OF SPERM CELL VIABILITY, ACROSOMAL INTEGRITY, AND MITOCHONDRIAL-FUNCTION USING FLOW-CYTOMETRY [J].
GRAHAM, JK ;
KUNZE, E ;
HAMMERSTEDT, RH .
BIOLOGY OF REPRODUCTION, 1990, 43 (01) :55-64
[8]   Assessment of sperm quality: a flow cytometric approach [J].
Graham, JK .
ANIMAL REPRODUCTION SCIENCE, 2001, 68 (3-4) :239-247
[9]  
JOHNSON LA, 1994, CYTOMETRY S7, V17, P83
[10]   A triple-stain flow cytometric method to assess plasma- and acrosome-membrane integrity of cryopreserved bovine sperm immediately after thawing in presence of egg-yolk particles [J].
Nagy, S ;
Jansen, J ;
Topper, EK ;
Gadella, BM .
BIOLOGY OF REPRODUCTION, 2003, 68 (05) :1828-1835