Performance of different photovoltaic-thermal (PVT) configurations integrated on prototype test cells: An experimental approach

被引:16
作者
Tomar, Vivek [1 ]
Tiwari, G. N. [1 ]
Bhatti, T. S. [1 ]
机构
[1] Indian Inst Technol IIT Delhi, Ctr Energy Studies, New Delhi 110016, India
关键词
Photovoltaic-thermal (PVT) system; Semi-transparent/opaque photovoltaic; Air heating system; Thermal modelling; Test cell; Mass flow rate; SOLAR COLLECTORS; EXERGY ANALYSIS; OPTIMUM TILT; BISPVT SYSTEM; ENERGY; MODEL; TECHNOLOGY; SIMULATION; EFFICIENCY; RADIATION;
D O I
10.1016/j.enconman.2017.11.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
Analytical model for temperature dependent electrical and thermal efficiency for four different photovoltaic thermal configurations integrated on identical prototype test cells namely; Case 1: glass to glass photovoltaic with duct integrated on a test cell, Case 2: glass to glass photovoltaic without duct integrated on a test cell, Case 3: glass to tedlar photovoltaic with duct integrated on a test cell and, Case 4: glass to tedlar photovoltaic without duct integrated on a test cell is developed in absence of ambient air exchange and experimentally validated in New Delhi's winter and summer seasonal conditions. The glass to glass photovoltaic module gives better performance in both electrical as well as thermal aspects, and gives daily average eta(m), 11,91% and 11.96% in summer whereas in winter, it gives 12.65% and 12.70% for case 1 and 2 respectively. Similarly, daily average eta(ith) was 32.77% and 25.44% for case 1 and 2 respectively in winter. Ducted cases 1 and 3 have higher eta(m) and eta(ith) due to the large heat dissipation capacity. Constant temperature mode operations inside test cells were attained, and we also discuss the effect of varying mass flow rate on electrical efficiency for ducted cases. Further, the yearly round electrical, thermal, overall thermal, and overall exergy efficiencies for case 1 were found respectively 10.41%, 34.35%, 61.52% and 13.72% under typical New Delhi weather condition. The characteristic equations for all four cases were also been developed.
引用
收藏
页码:394 / 419
页数:26
相关论文
共 59 条
  • [1] Performance analysis of a novel rotationally asymmetrical compound parabolic concentrator
    Abu-Bakar, Siti Hawa
    Muhammad-Sukki, Firdaus
    Freier, Daria
    Ramirez-Iniguez, Roberto
    Mallick, Tapas Kumar
    Munir, Abu Bakar
    Yasin, Siti Hajar Mohd
    Mas'ud, Abdullahi Abubakar
    Yunus, Norhidayah Md
    [J]. APPLIED ENERGY, 2015, 154 : 221 - 231
  • [2] Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions
    Agrawal, Basant
    Tiwari, G. N.
    [J]. APPLIED ENERGY, 2010, 87 (02) : 417 - 426
  • [3] Ahmad M.J., 2009, Open Renewable Energy Journal, V2, P19
  • [4] Drying of mint leaves in a solar dryer and under open sun: Modelling, performance analyses
    Akpinar, E. Kayak
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2407 - 2418
  • [5] A high efficiency solar air conditioner using concentrating photovoltaic/thermal collectors
    Al-Alili, A.
    Hwang, Y.
    Radermacher, R.
    Kubo, I.
    [J]. APPLIED ENERGY, 2012, 93 : 138 - 147
  • [6] Optimal tilt angle trajectory for maximizing solar energy potential in Ma'an area in Jordan
    Altarawneh, Ibrahem S.
    Rawadieh, Saleh I.
    Tarawneh, Muafag S.
    Alrowwad, Sultan M.
    Rimawi, Firas
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2016, 8 (03)
  • [7] Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
    Amori, Karima E.
    Al-Najjar, Hussein M. Taqi
    [J]. APPLIED ENERGY, 2012, 98 : 384 - 395
  • [8] [Anonymous], 1958, T C US SOL EN
  • [9] [Anonymous], 2009, 60891 IEC
  • [10] Bambara J., 2012, INT HIGH PERF BUILD