Attenuation Characteristics and Time Delay of PD Electromagnetic Wave Propagation in GIS Systems

被引:8
|
作者
Zhao, Tao [1 ]
Judd, Martin D. [2 ]
Stewart, Brian G. [3 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, Baoding 071003, Peoples R China
[2] High Frequency Diagnost & Engn Ltd, Glasgow G14 0BX, Lanark, Scotland
[3] Univ Strathclyde, Inst Energy & Environm, Glasgow G1 1XW, Lanark, Scotland
关键词
Gas insulation; Partial discharges; Probes; Electric fields; Reflection; Attenuation; Delay effects; Electromagnetic wave; propagation behavior; reflection effect; time delay; sensor location; PARTIAL DISCHARGE; UHF SIGNALS; MODEL TANK; T-BRANCH; TRANSMISSION; EXCITATION; SIMULATION; GUIDE;
D O I
10.1109/TPWRD.2021.3074515
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modeling of electromagnetic wave propagation inside a gas-insulated switchgear structure can be helpful for understanding and improving the utilization of partial discharge detection by providing information to help determine more optimal positioning of ultra-high frequency sensors. This paper studies the effect of insulating spacers, L- and T-type structures on electromagnetic wave propagation by simulating the time dependent wave propagation behavior for these arrangements within a gas-insulated switchgear busbar geometry. The attenuation characteristics and time delays produced by spacers, L- and T-type structures for partial discharge electromagnetic wave propagation behavior are presented. Emphasis is placed on comparison of attenuation characteristics and time delay between different observation points along the busbar both before and after the 90 degrees bends formed by L- and T-type structures. Moreover, a comparative analysis of the radial electric field at the gas-insulated switchgear tank and its rate of change with time is also conducted. The paper demonstrates that if the location of the ultra-high frequency sensor is chosen appropriately based on knowledge of the physical structures, the attenuation effects introduced by L- and T-type structures could be reduced.
引用
收藏
页码:937 / 946
页数:10
相关论文
共 50 条
  • [41] L 2 disturbance attenuation for a class of time-delay Hamiltonian systems
    Sun, Weiwei
    Wang, Yuzhen
    Yang, Renming
    JOURNAL OF SYSTEMS SCIENCE & COMPLEXITY, 2011, 24 (04) : 672 - 682
  • [42] Validations of simulation of UHF electromagnetic wave propagation in an oil-filled tank by time-domain measurements
    Umemoto, Takahiro
    Tenbohlen, Stefan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (09) : 1646 - 1652
  • [43] Investigation of Propagation Characteristics of UHF Electro-magnetic Wave Due to PD in Switchgear
    Luo, Hanwu
    Cheng, Peng
    Liu, Haibo
    Kang, Kai
    Yang, Fan
    Yang, Qi
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 2269 - 2272
  • [44] Investigation on the Propagation Characteristics of PD-Induced Electromagnetic Waves in an Actual 110 kV Power Transformer and Its Simulation Results
    Du, Jinchao
    Chen, Weigen
    Cui, Lu
    Zhang, Zhixian
    Tenbohlen, Stefan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 1941 - 1948
  • [45] Characteristics of the electromagnetic wave propagation in magnetized plasma sheath and practical method for blackout mitigation
    Wu, Xiang
    Zhang, Jiahui
    Dong, Guoxiang
    Shi, Lei
    CHINESE PHYSICS B, 2024, 33 (05)
  • [46] Propogation characteristics of PD-induced UHF signal in 126 kV GIS with three-phase construction based on time-frequency analysis
    Li, Xi
    Wang, Xiaohua
    Yang, Aijun
    Xie, Dingli
    Ding, Dan
    Rong, Mingzhe
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (07) : 805 - 812
  • [47] Propagation characteristics of time reversal pulsed electromagnetic waves in double negative materials
    Zhao De-Shuang
    Yue Wen-Jun
    Yu Min
    Zhang Sheng-Xue
    ACTA PHYSICA SINICA, 2012, 61 (07)
  • [48] Frequency-domain Transmission Characteristics of Electromagnetic Wave Signals Excited by Partial Discharge in GIS
    Miao Peiqing
    Li Xiuwei
    Ye Haifeng
    Sheng Gehao
    Jiang Xiuchen
    2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 511 - 515
  • [49] L2 disturbance attenuation for a class of time-delay Hamiltonian systems
    Weiwei Sun
    Yuzhen Wang
    Renming Yang
    Journal of Systems Science and Complexity, 2011, 24 : 672 - 682
  • [50] Tuning PD and PID Controllers for Double Integrating Plus Time Delay Systems
    Di Ruscio, David
    Dalen, Christer
    MODELING IDENTIFICATION AND CONTROL, 2017, 38 (02) : 95 - 110