The ocular pulse amplitude at different intraocular pressure: a prospective study

被引:14
|
作者
Knecht, Pascal Bruno [1 ]
Bosch, Martina Monika [1 ]
Michels, Stephan [1 ,2 ]
Mannhardt, Soenke [1 ]
Schmid, Ursina [1 ]
Bosch, Martin Albert [1 ]
Menke, Marcel Nico [1 ]
机构
[1] Univ Zurich Hosp, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Triemli Hosp Zurich, Dept Ophthalmol, Zurich, Switzerland
关键词
dynamic contour tonometry; intraocular pressure; intravitreal injection; ocular pulse amplitude; CHOROIDAL BLOOD-FLOW; DYNAMIC CONTOUR TONOMETRY; MACULAR DEGENERATION; INTRAVITREAL INJECTIONS; VOLUME; RIGIDITY; GLAUCOMA; EYES; PARAMETERS; LENGTH;
D O I
10.1111/j.1755-3768.2011.02141.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length. Methods: In a prospective, single centre study, OPA and IOP as measured by dynamic contour tonometry (DCT) were taken before baseline-and post-OPA (delta) intravitreal injection of 0.05 ml anti-vascular endothelial growth factor agents. Analysis was performed employing linear regression with baseline-and post (delta)-OPA differences as the dependent and post-IOP as well as delta IOP as the independent variable. A multilinear regression analysis with delta OPA as the dependent variable and baseline IOP, post-IOP, CCT and axial length as independent variables was conducted. Results: Forty eyes of 40 patients were included. IOP and OPA increased significantly after injection (IOP mean increase +/- SD: 17.83 +/- 9.83 mmHg, p < 0.001; OPA mean increase +/- SD: 1.39 +/- 1.16 mmHg, p < 0.001). For every mmHg increase in IOP, the OPA showed a linear increase of 0.05 mmHg (slope 0.05, 95% CI: 0.02-0.09, p = 0.003, r(2) = 0.20). Multiple regression analysis with delta OPA as the dependent variable revealed a partial correlation coefficient of 0.47 (p = 0.003) for post-IOP as the only significant contribution. Conclusion: A clear positive relationship between OPA measurements and IOP levels was shown in a clinical routine setting using DCT focusing on baseline and postinterventional comparisons of OPA values after intravitreal injections in patients with exudative age related macular degeneration. When considering the OPA for diagnostic purposes, we recommend indication of corresponding IOP values.
引用
收藏
页码:E466 / E471
页数:6
相关论文
共 50 条
  • [41] Ocular pulse amplitude after trabeculectomy
    von Schulthess, SR
    Kaufmann, C
    Bachmann, LM
    Yanar, A
    Thiel, MA
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (01) : 46 - 51
  • [42] Ocular pulse amplitude after trabeculectomy
    Sandra R. von Schulthess
    Claude Kaufmann
    Lucas M. Bachmann
    Ahmet Yanar
    Michael A. Thiel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 46 - 51
  • [43] A Compact Optical Pressure Measurement System for Acquiring Intraocular Pressure and Ocular Pulse
    Phan, Alex
    Joslin, Kevin
    Truong, Phuong
    Camp, Andrew
    Talke, Frank E.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4212 - 4216
  • [44] Changes in intraocular pressure and ocular pulse amplitude of rhesus macaques after blue light scleral cross-linking
    Chong Liu
    Yu Li
    Mengmeng Wang
    Jing Li
    Ningli Wang
    Fengju Zhang
    BMC Ophthalmology, 22
  • [45] A study comparing ocular pressure pulse and ocular fundus pulse in dependence of axial eye length and ocular volume
    Berisha, Fatmire
    Findl, Oliver
    Lasta, Michael
    Kiss, Barbara
    Schmetterer, Leopold
    ACTA OPHTHALMOLOGICA, 2010, 88 (07) : 766 - 772
  • [46] Ocular Pulse Amplitude Measurement Using Pascal Dynamic Contour Tonometer in Glaucoma Patients
    Katsimpris, J. M.
    Theoulakis, P. E.
    Papadopoulos, G. E.
    Katsimpris, A.
    Lepidas, J.
    Petropoulos, I. K.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (04) : 363 - 367
  • [47] The clinical utility of dynamic contour tonometry and ocular pulse amplitude
    Weizer, Jennifer S.
    Asrani, Sanjay
    Stinnett, Sandra S.
    Herndon, Leon W.
    JOURNAL OF GLAUCOMA, 2007, 16 (08) : 700 - 703
  • [48] Intraocular Pressure and Its Relation to Ocular Geometry: Results From the Gutenberg Health Study
    Hoffmann, Esther M.
    Aghayeva, Fidan
    Wagner, Felix M.
    Fiess, Achim
    Nagler, Markus
    Muenzel, Thomas
    Wild, Philipp S.
    Beutel, Manfred E.
    Schmidtmann, Irene
    Lackner, Karl J.
    Pfeiffer, Norbert
    Schuster, Alexander K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (01)
  • [49] Measuring intraocular pressure by different methods
    Lamparter, J.
    Hoffmann, E. M.
    OPHTHALMOLOGE, 2009, 106 (08): : 676 - 682
  • [50] Estimation of Ocular Rigidity in Glaucoma Using Ocular Pulse Amplitude and Pulsatile Choroidal Blood Flow
    Wang, Jing
    Freeman, Ellen E.
    Descovich, Denise
    Harasymowycz, Paul J.
    Fansi, Alvine Kamdeu
    Li, Gisele
    Lesk, Mark R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) : 1706 - 1711