The ocular pulse amplitude at different intraocular pressure: a prospective study

被引:14
|
作者
Knecht, Pascal Bruno [1 ]
Bosch, Martina Monika [1 ]
Michels, Stephan [1 ,2 ]
Mannhardt, Soenke [1 ]
Schmid, Ursina [1 ]
Bosch, Martin Albert [1 ]
Menke, Marcel Nico [1 ]
机构
[1] Univ Zurich Hosp, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Triemli Hosp Zurich, Dept Ophthalmol, Zurich, Switzerland
关键词
dynamic contour tonometry; intraocular pressure; intravitreal injection; ocular pulse amplitude; CHOROIDAL BLOOD-FLOW; DYNAMIC CONTOUR TONOMETRY; MACULAR DEGENERATION; INTRAVITREAL INJECTIONS; VOLUME; RIGIDITY; GLAUCOMA; EYES; PARAMETERS; LENGTH;
D O I
10.1111/j.1755-3768.2011.02141.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length. Methods: In a prospective, single centre study, OPA and IOP as measured by dynamic contour tonometry (DCT) were taken before baseline-and post-OPA (delta) intravitreal injection of 0.05 ml anti-vascular endothelial growth factor agents. Analysis was performed employing linear regression with baseline-and post (delta)-OPA differences as the dependent and post-IOP as well as delta IOP as the independent variable. A multilinear regression analysis with delta OPA as the dependent variable and baseline IOP, post-IOP, CCT and axial length as independent variables was conducted. Results: Forty eyes of 40 patients were included. IOP and OPA increased significantly after injection (IOP mean increase +/- SD: 17.83 +/- 9.83 mmHg, p < 0.001; OPA mean increase +/- SD: 1.39 +/- 1.16 mmHg, p < 0.001). For every mmHg increase in IOP, the OPA showed a linear increase of 0.05 mmHg (slope 0.05, 95% CI: 0.02-0.09, p = 0.003, r(2) = 0.20). Multiple regression analysis with delta OPA as the dependent variable revealed a partial correlation coefficient of 0.47 (p = 0.003) for post-IOP as the only significant contribution. Conclusion: A clear positive relationship between OPA measurements and IOP levels was shown in a clinical routine setting using DCT focusing on baseline and postinterventional comparisons of OPA values after intravitreal injections in patients with exudative age related macular degeneration. When considering the OPA for diagnostic purposes, we recommend indication of corresponding IOP values.
引用
收藏
页码:E466 / E471
页数:6
相关论文
共 50 条
  • [31] The Involutional Change of the Anterior Segment Morphology, Intraocular Pressure and Ocular Pulse Amplitude and the Effect of Glaucoma on this Change
    Comert, Ebru
    Beden, Umit
    Kuruoglu, Seda
    Sonmez, Baris
    Ozarslan, Mehtap
    Yeter, Volkan
    Oge, Ihsan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (01): : 27 - 31
  • [32] Ocular pulse amplitude as a dynamic parameter and its relationship with 24-h intraocular pressure and blood pressure in glaucoma
    Kim, Yoon Jeon
    Lee, Kyoung Sub
    Lee, Jong Rak
    Na, Jung Hwa
    Choi, Jaewan
    Han, Seungbong
    Kook, Michael S.
    EXPERIMENTAL EYE RESEARCH, 2013, 115 : 65 - 72
  • [33] The Dynamic Response of Intraocular Pressure and Ocular Pulse Amplitude to Acute Hemodynamic Changes in Normal and Glaucomatous Eyes
    Li, Jonathan C.
    Gupta, Vivek K.
    You, Yuyi
    Ng, Keith W.
    Graham, Stuart L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 6960 - 6967
  • [34] Travoprost- and Tafluprost-induced Changes in Intraocular Pressure and Ocular Pulse Amplitude
    Lee, Gyeong Min
    Ha, Seung Joo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (09): : 1235 - 1242
  • [35] The Effect of Non-Depolarising Muscle Relaxants on Ocular Pulse Amplitude and Intraocular Pressure
    Zuche, H.
    Morinello, E.
    Viestenz, Anja
    Fiorentzis, M. F.
    Volk, T.
    Seitz, B.
    Viestenz, Arne
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (12) : 1397 - 1401
  • [36] Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma
    Cheng, Lingyan
    Ding, Yuzhi
    Duan, Xuanchu
    Wu, Zhifeng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (05) : 4148 - 4152
  • [37] Comparison of the quality score of intraocular pressure and ocular pulse amplitude values measured by the Pascal dynamic contour tonometer
    Pourjavan S.
    Boghossian P.
    Detry-Morel M.
    International Ophthalmology, 2010, 30 (1) : 1 - 5
  • [38] Review on Dynamic Contour Tonometry and Ocular Pulse Amplitude
    Willekens, Koen
    Rocha, Rita
    Van Keer, Karel
    Vandewalle, Evelien
    Pinto, Lus Abegao
    Stalmans, Ingeborg
    Marques-Neves, Carlos
    OPHTHALMIC RESEARCH, 2016, 55 (02) : 91 - 98
  • [39] Ocular pulse amplitude and associated glaucomatous risk factors in a healthy Hispanic population
    Erickson, Dina H.
    Goodwin, Denise
    Anderson, Chad
    Hayes, John R.
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (08) : 408 - 413
  • [40] Ocular Pulse Amplitude in Patients with Asymmetric Primary Open-Angle Glaucoma
    Kac, Marcelo Jarczun
    Solari, Helena Parente
    Velarde, Guillermo Coca
    Brazuna, Rodrigo
    Cardoso, Gilberto Perez
    Ventura, Marcelo Palis
    CURRENT EYE RESEARCH, 2011, 36 (08) : 727 - 732