The ocular pulse amplitude at different intraocular pressure: a prospective study

被引:14
|
作者
Knecht, Pascal Bruno [1 ]
Bosch, Martina Monika [1 ]
Michels, Stephan [1 ,2 ]
Mannhardt, Soenke [1 ]
Schmid, Ursina [1 ]
Bosch, Martin Albert [1 ]
Menke, Marcel Nico [1 ]
机构
[1] Univ Zurich Hosp, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Triemli Hosp Zurich, Dept Ophthalmol, Zurich, Switzerland
关键词
dynamic contour tonometry; intraocular pressure; intravitreal injection; ocular pulse amplitude; CHOROIDAL BLOOD-FLOW; DYNAMIC CONTOUR TONOMETRY; MACULAR DEGENERATION; INTRAVITREAL INJECTIONS; VOLUME; RIGIDITY; GLAUCOMA; EYES; PARAMETERS; LENGTH;
D O I
10.1111/j.1755-3768.2011.02141.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length. Methods: In a prospective, single centre study, OPA and IOP as measured by dynamic contour tonometry (DCT) were taken before baseline-and post-OPA (delta) intravitreal injection of 0.05 ml anti-vascular endothelial growth factor agents. Analysis was performed employing linear regression with baseline-and post (delta)-OPA differences as the dependent and post-IOP as well as delta IOP as the independent variable. A multilinear regression analysis with delta OPA as the dependent variable and baseline IOP, post-IOP, CCT and axial length as independent variables was conducted. Results: Forty eyes of 40 patients were included. IOP and OPA increased significantly after injection (IOP mean increase +/- SD: 17.83 +/- 9.83 mmHg, p < 0.001; OPA mean increase +/- SD: 1.39 +/- 1.16 mmHg, p < 0.001). For every mmHg increase in IOP, the OPA showed a linear increase of 0.05 mmHg (slope 0.05, 95% CI: 0.02-0.09, p = 0.003, r(2) = 0.20). Multiple regression analysis with delta OPA as the dependent variable revealed a partial correlation coefficient of 0.47 (p = 0.003) for post-IOP as the only significant contribution. Conclusion: A clear positive relationship between OPA measurements and IOP levels was shown in a clinical routine setting using DCT focusing on baseline and postinterventional comparisons of OPA values after intravitreal injections in patients with exudative age related macular degeneration. When considering the OPA for diagnostic purposes, we recommend indication of corresponding IOP values.
引用
收藏
页码:E466 / E471
页数:6
相关论文
共 50 条
  • [21] Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
    Figueiredo, Bruno P.
    Cronemberger, Sebastiao
    Kanadani, Fabio N.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1615 - 1621
  • [22] Changes in ocular pulse amplitude and choroidal thickness in childhood obesity patients with and without insulin resistance
    Aydemir, Gozde Aksoy
    Aydemir, Emre
    Asik, Abdulvahit
    Bolu, Semih
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (04) : 2018 - 2025
  • [23] Temporal characteristics of the Ocular Pulse Amplitude and their dependence on average intraocular pressure
    Karyotakis, N.
    Ginis, H.
    Dastiridou, A.
    Tsilimbaris, M.
    Pallikaris, I.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [24] Effects of corneal thickness and axial length on intraocular pressure and ocular pulse amplitude before and after cataract surgery
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    Ohsugi, Hideharu
    Nakakura, Shunsuke
    Han, Zaigen
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2011, 46 (03): : 242 - 246
  • [25] The Effect of Trabeculectomy on Ocular Pulse Amplitude
    Breusegem, Christophe
    Fieuws, Steffen
    Zeyen, Thierry
    Stalmans, Ingeborg
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (01) : 231 - 235
  • [26] Role of Ocular Pulse Amplitude in Glaucoma
    Stuermer, J. P. E.
    Kniestedt, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (02) : 162 - 168
  • [27] Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
    Villas-Boas, Flavia Silva
    Doi, Larissa Morimoto
    Siqueira Sousa, Aline Katia
    Melo, Luiz Alberto S., Jr.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (03) : 296 - 301
  • [28] Changes in intraocular pressure and ocular pulse amplitude of rhesus macaques after blue light scleral cross-linking
    Liu, Chong
    Li, Yu
    Wang, Mengmeng
    Li, Jing
    Wang, Ningli
    Zhang, Fengju
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [29] Ocular Pulse Amplitude in Patients With Descemet Stripping Endothelial Keratoplasty
    Jivrajka, Renu
    Schultz, Kara L.
    Price, Marianne O.
    Price, Frances W.
    Wilensky, Jacob T.
    Edward, Deepak P.
    Vajaranant, Thasarat S.
    JOURNAL OF GLAUCOMA, 2014, 23 (03) : 142 - 144
  • [30] Influence of Ocular Pulse Amplitude on Ocular Response Analyzer Measurements
    Xu, Guihua
    Lam, Dennis Shun
    Leung, Christopher Kai-shun
    JOURNAL OF GLAUCOMA, 2011, 20 (06) : 344 - 349