The ocular pulse amplitude at different intraocular pressure: a prospective study

被引:14
|
作者
Knecht, Pascal Bruno [1 ]
Bosch, Martina Monika [1 ]
Michels, Stephan [1 ,2 ]
Mannhardt, Soenke [1 ]
Schmid, Ursina [1 ]
Bosch, Martin Albert [1 ]
Menke, Marcel Nico [1 ]
机构
[1] Univ Zurich Hosp, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Triemli Hosp Zurich, Dept Ophthalmol, Zurich, Switzerland
关键词
dynamic contour tonometry; intraocular pressure; intravitreal injection; ocular pulse amplitude; CHOROIDAL BLOOD-FLOW; DYNAMIC CONTOUR TONOMETRY; MACULAR DEGENERATION; INTRAVITREAL INJECTIONS; VOLUME; RIGIDITY; GLAUCOMA; EYES; PARAMETERS; LENGTH;
D O I
10.1111/j.1755-3768.2011.02141.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length. Methods: In a prospective, single centre study, OPA and IOP as measured by dynamic contour tonometry (DCT) were taken before baseline-and post-OPA (delta) intravitreal injection of 0.05 ml anti-vascular endothelial growth factor agents. Analysis was performed employing linear regression with baseline-and post (delta)-OPA differences as the dependent and post-IOP as well as delta IOP as the independent variable. A multilinear regression analysis with delta OPA as the dependent variable and baseline IOP, post-IOP, CCT and axial length as independent variables was conducted. Results: Forty eyes of 40 patients were included. IOP and OPA increased significantly after injection (IOP mean increase +/- SD: 17.83 +/- 9.83 mmHg, p < 0.001; OPA mean increase +/- SD: 1.39 +/- 1.16 mmHg, p < 0.001). For every mmHg increase in IOP, the OPA showed a linear increase of 0.05 mmHg (slope 0.05, 95% CI: 0.02-0.09, p = 0.003, r(2) = 0.20). Multiple regression analysis with delta OPA as the dependent variable revealed a partial correlation coefficient of 0.47 (p = 0.003) for post-IOP as the only significant contribution. Conclusion: A clear positive relationship between OPA measurements and IOP levels was shown in a clinical routine setting using DCT focusing on baseline and postinterventional comparisons of OPA values after intravitreal injections in patients with exudative age related macular degeneration. When considering the OPA for diagnostic purposes, we recommend indication of corresponding IOP values.
引用
收藏
页码:E466 / E471
页数:6
相关论文
共 50 条
  • [1] Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver
    Aykan, Umit
    Erdurmus, Mesut
    Yilmaz, Burhan
    Bilge, Ahmet Hamdi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (08) : 1183 - 1186
  • [2] Relationship Between Subfoveal Choroidal Thickness, Ocular Pulse Amplitude, and Intraocular Pressure in Healthy Subjects
    Pekel, Gokhan
    Acer, Semra
    Yagci, Ramazan
    Ozdemir, Seyfullah
    Kaya, Huseyin
    Hiraali, Mehmet C.
    Cetin, Ebru N.
    JOURNAL OF GLAUCOMA, 2016, 25 (07) : 613 - 617
  • [3] Changes in intraocular pressure and ocular pulse amplitude with accommodation
    Read, Scott A.
    Collins, Michael J.
    Becker, Heidi
    Cutting, Jeremy
    Ross, Danielle
    Savill, Annyck K.
    Trevor, Beth
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (03) : 332 - 335
  • [4] Effects of body mass index on intraocular pressure and ocular pulse amplitude
    Karadag, Remzi
    Arslanyilmaz, Zeynel
    Aydin, Bahri
    Hepsen, Ibrahim F.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (05) : 605 - 608
  • [5] Reproducibility of measurements of ocular pulse amplitude and intraocular pressure using SmartLens®
    Vogel, A
    Beck, S
    Schwenn, O
    Grus, F
    Krummenauer, F
    Pfeiffer, N
    OPHTHALMOLOGE, 2001, 98 (10): : 944 - 949
  • [6] Relationship between ocular pulse amplitude and systemic blood pressure measurements
    Grieshaber, Matthias C.
    Katamay, Robert
    Gugleta, Konstantin
    Kochkorov, Asan
    Flammer, Josef
    Orgul, Selim
    ACTA OPHTHALMOLOGICA, 2009, 87 (03) : 329 - 334
  • [7] Reduction of intraocular pressure and ocular pulse amplitude during general anesthesia
    Zuche, H. H.
    Morinello, E.
    Viestenz, A.
    Fiorentzis, M.
    Seitz, B.
    Volk, T.
    Viestenz, A.
    OPHTHALMOLOGE, 2015, 112 (09): : 764 - 769
  • [8] Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    Hoffmann E.M.
    Grus F.-H.
    Pfeiffer N.
    BMC Ophthalmology, 4 (1) : 1 - 7
  • [9] Effects of Swimming Goggles Wearing on Intraocular Pressure, Ocular Perfusion Pressure, and Ocular Pulse Amplitude
    Paula, Ana P. B.
    Paula, Jayter S.
    Silva, Marcelo J. L.
    Rocha, Eduardo M.
    De Moraes, Carlos G.
    Rodrigues, Maria L. V.
    JOURNAL OF GLAUCOMA, 2016, 25 (10) : 860 - 864
  • [10] Ocular Rigidity, Ocular Pulse Amplitude, and Pulsatile Ocular Blood Flow: The Effect of Intraocular Pressure
    Dastiridou, Anna I.
    Ginis, Harilaos S.
    De Brouwere, Dirk
    Tsilimbaris, Miltiadis K.
    Pallikaris, Ioannis G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5718 - 5722