Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis

被引:4
作者
Bomman, Shivanand [1 ]
Ashat, Munish [2 ]
Nagra, Navroop [1 ]
Jayaraj, Mahendran [3 ]
Chandra, Shruti [4 ]
Kozarek, Richard A. [1 ]
Ross, Andrew [1 ]
Krishnamoorthi, Rajesh [1 ]
机构
[1] Virginia Mason Med Ctr, Digest Dis Inst, 1100,9th Ave,Mail Stop C3-GAS, Seattle, WA 98101 USA
[2] Indiana Univ Hlth, Indianapolis, IN USA
[3] Univ Nevada, Las Vegas, NV 89154 USA
[4] Mayo Clin, Rochester, MN USA
关键词
Contamination; Culture; Duodenoscope sterilization; Ethylene oxide sterilization; High-level disinfection; Surveillance; HIGH-LEVEL DISINFECTION; STERILIZATION; QUARANTINE; QUALITY;
D O I
10.5946/ce.2021.212
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: 1. microbiological culture, 2. ethylene oxide sterilization, 3. liquid chemical sterilant processing system, and 4. double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. Methods: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRIs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. Results: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%-10.8%, inconsistency index [F]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%-2.7%, I-2 =94.96). Conclusions: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 26 条
  • [1] [Anonymous], 2015, SUPPL MEAS ENH DUOD
  • [2] [Anonymous], 2015, DES END RETR CHOL ER
  • [3] Equivalent performance of single-use and reusable duodenoscopes in a randomised trial
    Bang, Ji Young
    Hawes, Robert
    Varadarajulu, Shyam
    [J]. GUT, 2021, 70 (05) : 838 - 844
  • [4] A randomized trial of single versus double high-level disinfection of duodenoscopes and linear echoendoscopes using standard automated reprocessing
    Bartles, Rebecca L.
    Leggett, James E.
    Hove, Shannan
    Kashork, Catherine D.
    Wang, Lian
    Oethinger, Margret
    Baxter, Lynda
    Brandabur, Jack J.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2018, 88 (02) : 306 - +
  • [5] METAANALYSIS IN CLINICAL-TRIALS
    DERSIMONIAN, R
    LAIRD, N
    [J]. CONTROLLED CLINICAL TRIALS, 1986, 7 (03): : 177 - 188
  • [6] FDA, 2019, FDA CONT REM FAC IMP
  • [7] FDA, 2016, 522 POSTM SURV STUD
  • [8] FDA, 2019, FDA IS REC TRANS DUO
  • [9] FDA, 2019, RED RISK INF REPR DU
  • [10] FDA/CDC/ASM Working Group on Duodenoscope Culturing, 2018, DUOD SURV SAMPL CULT