Assessment of renal function in renal transplant patients using cystatin C. A comparison to other renal function markers and estimates

被引:43
作者
Risch, L
Blumberg, A
Huber, AR [1 ]
机构
[1] Kantonsspital, Dept Lab Med, CH-5001 Aarau, Switzerland
[2] Kantonsspital, Dept Nephrol, CH-5001 Aarau, Switzerland
关键词
beta-2-microglobulin; creatinine; cystatin C; glomerular filtration rate; kidney transplantation; renal function equations;
D O I
10.1081/JDI-100104727
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To date, little evidence is available to define the role of cystatin C in patients with renal transplants. Thus, to assess, whether cystatin C (CysC) provides better information on renal function than other markers, CysC, creatinine clearance (CrCl), serum creatinine (SCr), beta (2)-microglobulin (beta (2)-M), and I-125-Iothalamate clearance were determined in 30 patients. Correlation and ROC curves were obtained and characteristics like sensitivity and specificity were calculated. Further, to evaluate the usefulness of these markers for monitoring, intraindividual coefficients of variation for CysC and SCr measurements were compared in 85 renal transplant patients. CysC correlated best with GFR, whereas SCr, CrCl and beta (2)-M all had lower correlation coefficients. CysC was superior to SCr, even when renal function equations of were used. The diagnostic accuracy of CysC was significantly better than SCr, but did not differ significantly from CrCl and beta (2)-M. Together, our data show that in patients with renal transplants, CysC has a similar diagnostic value as CrCl. However, it is superior to determinations of SCr. The intraindividual variation of CysC is significantly greater than that of SCr. This might be due to better ability of CysC to reflect temporary changes especially in mildly impaired GFR, most critical for early detection of rejection and other function impairment. In conclusion, CysC allows for easy and accurate assessment of renal function (GFR) in steady state renal transplant patients and is clearly superior to the commonly used serum creatinine.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 20 条
[1]   Cystatin C - A new marker of glomerular filtration rate in children independent of age and height [J].
Bokenkamp, A ;
Domanetzki, M ;
Zinck, R ;
Schumann, G ;
Byrd, D ;
Brodehl, J .
PEDIATRICS, 1998, 101 (05) :875-881
[2]   CHARACTERIZATION OF CREATININE ERROR IN KETOTIC PATIENTS - A PROSPECTIVE COMPARISON OF ALKALINE PICRATE METHODS WITH AN ENZYMATIC METHOD [J].
GERARD, SK ;
KHAYAMBASHI, H .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1985, 84 (05) :659-664
[3]   Predictive performance of renal function estimate equations in renal allografts [J].
Goerdt, PJ ;
HeimDuthoy, KL ;
Macres, M ;
Swan, SK .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 44 (03) :261-265
[4]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[5]  
Harmoinen APT, 1999, CLIN NEPHROL, V52, P363
[6]  
Henne V, 1997, ANTICANCER RES, V17, P2915
[7]   MEASUREMENT OF GLOMERULAR FILTRATION-RATE UTILIZING A SINGLE SUBCUTANEOUS INJECTION OF IOTHALAMATE-I-125 [J].
ISRAELIT, AH ;
LONG, DL ;
WHITE, MG ;
HULL, AR .
KIDNEY INTERNATIONAL, 1973, 4 (05) :346-349
[8]   CYSTATIN-C - A PROMISING MARKER OF GLOMERULAR-FILTRATION RATE TO REPLACE CREATININE [J].
JUNG, K ;
JUNG, M .
NEPHRON, 1995, 70 (03) :370-371
[9]  
Keevil BG, 1998, CLIN CHEM, V44, P1535
[10]   DEVELOPMENT OF AN AUTOMATED KINETIC JAFFE METHOD DESIGNED TO MINIMIZE BILIRUBIN INTERFERENCE IN PLASMA CREATININE ASSAYS [J].
KNAPP, ML ;
MAYNE, PD .
CLINICA CHIMICA ACTA, 1987, 168 (02) :239-246