Highly Sensitive and Selective Detection of Dopamine at Poly (chromotrope 2B)-Modified Glassy Carbon Electrode in the Presence of Uric Acid and Ascorbic Acid

被引:63
|
作者
Li, Xiao-Bo [1 ,2 ,3 ]
Rahman, Md Mahbubur [2 ,3 ]
Xu, Guang-Ri [1 ]
Lee, Jae-Joon [2 ,3 ]
机构
[1] Henan Inst Sci & Technol, Dept Chem & Chem Engn, Xinxiang 453003, Peoples R China
[2] Konkuk Univ, Coll Biomed & Hlth Sci, Nanotechnol Res Ctr, Chungju 380701, South Korea
[3] Konkuk Univ, Coll Biomed & Hlth Sci, Dept Appl Life Sci, Chungju 380701, South Korea
基金
新加坡国家研究基金会;
关键词
Poly(chromotrope 2B); Dopamine; Ascorbic acid; Uric acid; Electrostatic interaction; PASTE ELECTRODE; ELECTROCHEMICAL DETERMINATION; BEHAVIOR; SURFACE; FILM; ACTIVATION; MICELLES; SDS;
D O I
10.1016/j.electacta.2015.05.062
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly sensitive and selective electrochemical method based on a poly(chromotrope 2B)-modified anodized glassy carbon electrode (PCHAGCE) was developed for the determination of dopamine (DA) in the presence of uric acid (UA) and ascorbic acid (AA). The PCHAGCE sensor exhibited excellent electron-mediating behavior towards the oxidation of DA in 0.1 M phosphate buffer solution (PBS) (pH 7.0). It was found that the electrocatalytic activity was significantly dependent on the charge status and molecular structure of the target molecules. Differential pulse voltammetry (DPV) measurements revealed oxidation signals for DA, UA, and AA that were well-resolved into three distinct peaks with AA-DA, DA-UA, and AA-UA peak potential separations (Delta E-p) of 172,132, and 304 mV, respectively. A detection limit of 0.04 +/- 0.001 mu M (S/N = 3) and a quantification limit (S/N = 10) of 0.149 +/- 0.03 mu M were obtained for DA sensing in a linear range of 1 to 40 mu M in PBS (pH 7.0) with a very high sensitivity of 1.522 +/- 0.032 mu A.mu M-1. The DA concentrations in human urine samples were also successfully determined with recoveries of 94.0-98.0%. This approach provides a simple, easy, sensitive, and selective method to detect DA in the presence of AA and UA. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 447
页数:8
相关论文
共 50 条
  • [21] Electrocatalytic oxidation and determination of dopamine in the presence of ascorbic acid and uric acid at a poly (p-nitrobenzenazo resorcinol) modified glassy carbon electrode
    Lin, Xinhua
    Zhang, Yafeng
    Chen, Wei
    Wu, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 309 - 314
  • [22] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [23] Polymethylthiophene/Nafion-modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid
    Vu Thi Huong
    Toshinori Shimanouchi
    Do Phuc Quan
    Hiroshi Umakoshi
    Pham Hung Viet
    Ryoichi Kuboi
    Journal of Applied Electrochemistry, 2009, 39 : 2035 - 2042
  • [24] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [25] Detection of Uric Acid in the Presence of Dopamine and High Concentration of Ascorbic Acid Using PDDA Modified Graphite Electrode
    Manjunatha, Hanumanthrayappa
    Nagaraju, Doddahalli Hanumantharayudu
    Suresh, Gurukar Shivappa
    Venkatesha, Thimmappa Venkatarangaiah
    ELECTROANALYSIS, 2009, 21 (20) : 2198 - 2206
  • [26] Selective Detection of Dopamine in Presence of Ascorbic Acid by Use of Glassy-Carbon Electrode Modified with Amino-β-Cyclodextrin and Carbon Nanotubes
    Gaied, Aymen
    Jaballah, Nejmeddine
    Tounsi, Moncef
    Braiek, Mohamed
    Jaffrezic-Renault, Nicole
    Majdoub, Mustapha
    ELECTROANALYSIS, 2014, 26 (12) : 2747 - 2753
  • [27] Highly selective determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using poly(sulfonazo III) modified glassy carbon electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, T.
    Arabzadeh, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (01): : 213 - 221
  • [28] Simultaneous and sensitive detection of dopamine and uric acid using a poly(L-methionine)/gold nanoparticle-modified glassy carbon electrode
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Maleki, Ali Asghar
    Safshekan, Saeid
    CHINESE JOURNAL OF CATALYSIS, 2014, 35 (03) : 423 - 429
  • [29] Poly (O-aminobenzoic acid) modified glassy carbon electrode for electrochemical detection of dopamine in the presence of ascorbic acid
    Zhang, YZ
    Jin, GY
    Cheng, WX
    Li, SP
    FRONTIERS IN BIOSCIENCE, 2005, 10 : 23 - 29
  • [30] Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Hao Tang
    Guang-zhi Hu
    Sheng-xiang Jiang
    Xia Liu
    Journal of Applied Electrochemistry, 2009, 39 : 2323 - 2328