Highly Sensitive and Selective Detection of Dopamine at Poly (chromotrope 2B)-Modified Glassy Carbon Electrode in the Presence of Uric Acid and Ascorbic Acid

被引:64
作者
Li, Xiao-Bo [1 ,2 ,3 ]
Rahman, Md Mahbubur [2 ,3 ]
Xu, Guang-Ri [1 ]
Lee, Jae-Joon [2 ,3 ]
机构
[1] Henan Inst Sci & Technol, Dept Chem & Chem Engn, Xinxiang 453003, Peoples R China
[2] Konkuk Univ, Coll Biomed & Hlth Sci, Nanotechnol Res Ctr, Chungju 380701, South Korea
[3] Konkuk Univ, Coll Biomed & Hlth Sci, Dept Appl Life Sci, Chungju 380701, South Korea
基金
新加坡国家研究基金会;
关键词
Poly(chromotrope 2B); Dopamine; Ascorbic acid; Uric acid; Electrostatic interaction; PASTE ELECTRODE; ELECTROCHEMICAL DETERMINATION; BEHAVIOR; SURFACE; FILM; ACTIVATION; MICELLES; SDS;
D O I
10.1016/j.electacta.2015.05.062
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly sensitive and selective electrochemical method based on a poly(chromotrope 2B)-modified anodized glassy carbon electrode (PCHAGCE) was developed for the determination of dopamine (DA) in the presence of uric acid (UA) and ascorbic acid (AA). The PCHAGCE sensor exhibited excellent electron-mediating behavior towards the oxidation of DA in 0.1 M phosphate buffer solution (PBS) (pH 7.0). It was found that the electrocatalytic activity was significantly dependent on the charge status and molecular structure of the target molecules. Differential pulse voltammetry (DPV) measurements revealed oxidation signals for DA, UA, and AA that were well-resolved into three distinct peaks with AA-DA, DA-UA, and AA-UA peak potential separations (Delta E-p) of 172,132, and 304 mV, respectively. A detection limit of 0.04 +/- 0.001 mu M (S/N = 3) and a quantification limit (S/N = 10) of 0.149 +/- 0.03 mu M were obtained for DA sensing in a linear range of 1 to 40 mu M in PBS (pH 7.0) with a very high sensitivity of 1.522 +/- 0.032 mu A.mu M-1. The DA concentrations in human urine samples were also successfully determined with recoveries of 94.0-98.0%. This approach provides a simple, easy, sensitive, and selective method to detect DA in the presence of AA and UA. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 447
页数:8
相关论文
共 52 条
[41]   Psychoanalytical electrochemistry: Dopamine and behavior [J].
Venton, BJ ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :414A-421A
[42]   Simultaneous determination of dopamine, uric acid and ascorbic acid with LaFeO3 nanoparticles modified electrode [J].
Wang, Guangfeng ;
Sun, Jingao ;
Zhang, Wei ;
Jiao, Shoufeng ;
Fang, Bin .
MICROCHIMICA ACTA, 2009, 164 (3-4) :357-362
[43]   A novel poly(taurine) modified glassy carbon electrode for the simultaneous determination of epinephrine and dopamine [J].
Wang, Yan ;
Chen, Zhen-Zhen .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) :322-327
[44]   Application of graphene-modified electrode for selective detection of dopamine [J].
Wang, Ying ;
Li, Yueming ;
Tang, Longhua ;
Lu, Jin ;
Li, Jinghong .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (04) :889-892
[45]  
Wightman R.M., 1988, ANAL CHEM, V60, P769, DOI DOI 10.1021/AC00164A001]
[46]   Electrochemical characterization of poly(eriochrome black T) modified glassy carbon electrode and its application to simultaneous determination of dopamine, ascorbic acid and uric acid [J].
Yao, Hong ;
Sun, Yuanyuan ;
Lin, Xinhua ;
Tang, Yuhai ;
Huang, Liying .
ELECTROCHIMICA ACTA, 2007, 52 (20) :6165-6171
[47]  
Yuan Y, 2008, B KOREAN CHEM SOC, V29, P1883
[48]   Electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH) at a chlorogenic acid modified glassy carbon electrode [J].
Zare, HR ;
Golabi, SM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (01) :14-23
[49]   Electrochemical behavior of a covalently modified glassy carbon electrode with aspartic acid and its use for voltammetric differentiation of dopamine and ascorbic acid [J].
Zhang, L ;
Lin, XQ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (07) :1669-1677
[50]   Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode [J].
Zhang, Rui ;
Jin, Gen-Di ;
Chen, Da ;
Hu, Xiao-Ya .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01) :174-181