Consistency of complex fractionated atrial electrograms during atrial fibrillation

被引:99
|
作者
Lin, Yenn-Jiang [1 ,2 ,3 ]
Tai, Ching-Tai [1 ]
Kao, Tsair [4 ]
Chang, Shih-Lin [1 ]
Wongcharoen, Wanwarang [2 ,3 ]
Lo, Li-Wei [2 ,3 ]
Tuan, Ta-Chuan [2 ,3 ]
Udyavar, Ameya R. [2 ,3 ]
Chen, Yi-Jen [5 ,6 ]
Higa, Satoshi [7 ]
Ueng, Kuo-Chang [8 ]
Chen, Shih-Ann [1 ,2 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Div Cardiol, Dept Med, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[3] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[5] Wang Fang Hosp, Taipei, Taiwan
[6] Taipei Med Univ, Taipei, Taiwan
[7] Univ Ryukyus, Fac Med, Dept Internal Med 2, Okinawa, Japan
[8] Chung Shan Med Univ, Taichung, Taiwan
关键词
atrial fibrillation; electrogram; frequency analysis; left atrium; mapping;
D O I
10.1016/j.hrthm.2007.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Temporal variation in complex fractionated atrial etectrograms (CFAEs) exists during atria[ fibrillation (AF). OBJECTIVE This study sought to quantify the variation in CFAEs using a fractionation interval (FI) algorithm and to define the shortest optimal recording duration required to consistently characterize the magnitude of the fractionation. METHODS Twenty-seven patients undergoing AF mapping in the Left atrium were studied. The FI and frequency analysis were performed at each mapped site for recording durations of I to 8 seconds. The magnitude of the fractionation was quantified by the FI algorithm, which calculated the mean interval between multiple, discrete deflections during AF. The results from each duration were statistically compared with the maximal-duration recording, as a standard. The FI values were compared with the dominant frequency values obtained from the associated frequency spectra. RESULTS The FIs obtained from recording durations between 5 and 8 seconds had a smaller variation in the FI (P < .05) and, for those sites with a FI < 50 ms, the fractionation was typically continuous. The fast-Fourier Transform spectra obtained from the CFAE sites with recording durations of > 5 seconds harbored higher dominant frequency values than those with shorter recording durations (8.1 +/- 2.5 Hz vs. 6.8 +/- 0.98 Hz, P <.05). The CFAE sites with continuous fractionation were Located within the pulmonary veins and their ostia in 77% of patients with paroxysmal AF, and in only 29% of patients with nonparoxysmal AF (P <.05). CONCLUSION The assessment of fractionated electrograms requires a recording duration of 5 seconds at each site to obtain a consistent fractionation. Sites with the shortest FIs consistently identified sites with the fastest electrograrn activity throughout the entire left atrium and pulmonary veins.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 50 条
  • [1] Automated detection and characterization of complex fractionated atrial electrograms in human left atrium during atrial fibrillation
    Scherr, Daniel
    Dalal, Darshan
    Cheema, Aamir
    Cheng, Alan
    Henrikson, Charles A.
    Spragg, David
    Marine, Joseph E.
    Berger, Ronald D.
    Cakins, Hugh
    Dong, Jun
    HEART RHYTHM, 2007, 4 (08) : 1013 - 1020
  • [2] Different properties of complex fractionated atrial electrograms during atrial fibrillation
    Lei, Sen
    Fang, Pi-hua
    Liu, Jun
    Hou, Yu
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2012, 13 (03) : 175 - 180
  • [3] Complex Fractionated Atrial Electrograms Is This the Beast to Tame in Atrial Fibrillation?
    Berenfeld, Omer
    Jalife, Jose
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (04): : 426 - 428
  • [4] Complex Fractionated Atrial Electrograms in Catheter Ablation of Atrial Fibrillation Dead and Buried?
    Chugh, Aman
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (05): : 999 - 1001
  • [5] Efficacy of Additional Ablation of Complex Fractionated Atrial Electrograms for Catheter Ablation of Nonparoxysmal Atrial Fibrillation
    Lin, Yenn-Jiang
    Tai, Ching-Tai
    Chang, Shih-Lin
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Wongcharoen, Wanwarang
    Udyavar, Ameya R.
    Hu, Yu-Feng
    Chang, Chien-Jung
    Tsai, Wen-Chin
    Kao, Tsair
    Higa, Satoshi
    Chen, Shin-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (06) : 607 - 615
  • [6] Spatial Relationships between the Pulmonary Veins and Sites of Complex Fractionated Atrial Electrograms During Atrial Fibrillation
    Chen, Jian
    Off, Morten Kristian
    Solheim, Eivind
    Hoff, Per Ivar
    Schuster, Peter
    Ohm, Ole-Jorgen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S190 - S193
  • [7] Correlation between atrial fibrillation driver locations and complex fractionated atrial electrograms in patients with persistent atrial fibrillation
    Ammar-Busch, Sonia
    Reents, Tilko
    Knecht, Sebastien
    Rostock, Thomas
    Arentz, Thomas
    Duytschaever, Mattias
    Neumann, Thomas
    Cauchemez, Bruno
    Albenque, Jean-Paul
    Hessling, Gabriele
    Deisenhofer, Isabel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (10): : 1279 - 1285
  • [8] Electrophysiologic Characteristics of Complex Fractionated Atrial Electrograms in Patients with Atrial Fibrillation
    Park, Jae H.
    Pak, Hui-Nam
    Kim, Sook K.
    Jang, Jin K.
    Choi, Jong I.
    Lim, Hong E.
    Hwang, Chun
    Kim, Young-Hoon
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 266 - 272
  • [9] Complex Fractionated Atrial Electrograms A Worthwhile Target for Ablation of Atrial Fibrillation?
    Latchamsetty, Rakesh
    Morady, Fred
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (02): : 117 - 118
  • [10] Characteristics and distribution of complex fractionated atrial electrograms in patients with paroxysmal and persistent atrial fibrillation
    Eivind Solheim
    Morten Kristian Off
    Per Ivar Hoff
    Peter Schuster
    Ole-Jørgen Ohm
    Jian Chen
    Journal of Interventional Cardiac Electrophysiology, 2010, 28 : 87 - 93