Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects

被引:1
作者
Kakhki, Vahid Reza Dabbagh [1 ]
Zakavi, Seyed Rasoul [1 ]
Sadeghi, Ramin [1 ]
机构
[1] Mashhad Univ Med Sci, Dept Nucl Med, Imam Reza Hosp, Mashhad, Iran
来源
HELLENIC JOURNAL OF NUCLEAR MEDICINE | 2007年 / 10卷 / 01期
关键词
gated SPET; left ventricular volume; ejection fraction; perfusion defects; summed rest score;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Emory cardiac toolbox (ECTb) and quantitative gated single photon emission tomography - SPET (QGS) software are the two most often used techniques for automatic calculation of left ventricular volumes (LVV) and ejection fraction (LVEF). Few studies have shown that these software are not interchangeable, however the effect of perfusion defects on performance of these software has not been widely studied. The aim of this study was to compare the performance of QGS and ECTb for the calculation of LVEF, end-systolic volume (ESV) and end-diastolic volume (EDV) in patients with normal and abnormal myocardial perfusion. One hundred and forty-four consecutive patients with suspected coronary artery disease underwent a two-day protocol with dipyridamole stress/rest gated technetium-99m-methoxy isobutyl isonitrile (Tc-99m-sestamibi) myocardial perfusion SPET (GSPET) (8 gates/cardiac cycles). Rest GSPET scintiscan findings were analyzed using QGS and ECTb. Correlation between the results of QGS and ECTb was greater than 90%. In patients with no perfusion defects, EDV and LVEF using ECTb, were significantly higher than using QGS (P<0.001), whereas no significant difference was noticed in ESV (P=0.741). In patients with perfusion defects, also ECTb yielded significantly higher values for EDV, ESV and LVEF than QGS (P<0.001). In tomograms of patients with perfusion defects, mean differences of EDV and ESV between the two software, were significantly higher than in tomograms of patients without defects (P<0.001), while for LVEF this difference was not significant (P=0.093). Patients were classified into three subgroups based on the summed rest score (SRS); G1: patients with SRS:53 (n=109), G2: patients with 4 <= SRS <= 8 (n=13) and G3: patients with SRS >= 9 (n=22). One-way ANOVA showed that the mean differences of EDV and ESV values between ECTb and QGS between the subgroups were significant (P<0.001 for both parameters), while no significant difference was noticed between the subgroups, as for the mean difference of LVEF, calculated by the two software (P=0.07). By increasing SRS, the EDV and ESV values were overestimated to a higher level by the ECTb as compared to the QGS software. Linear regression analysis showed that the difference in LVV values, between the two software increased, when SRS also increased (P<0.001). In conclusion, correlation between QGS and ECTb, software was very good both in patients with and without perfusion defects. In patients with perfusion defects, calculated LVEF, ESV and EDV values are higher using ECTb compared to the QGS software. However, the more extensive the perfusion defect was, the greater the difference of LVV between these two software. For the follow up of patients, we suggest the use of a single software either QGS or ECTb, for serial measurements of LV function.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 50 条
  • [41] Thallium-201 gated single-photon emission tomography for assessing left ventricular volumes and function in patients with aortic valve stenosis: Comparison with echocardiography as the reference standard
    Kurisu, Satoshi
    Iwasaki, Toshitaka
    Ikenaga, Hiroki
    Watanabe, Noriaki
    Higaki, Tadanao
    Shimonaga, Takashi
    Ishibashi, Ken
    Mitsuba, Naoya
    Dohi, Yoshihiro
    Kihara, Yasuki
    IJC HEART & VASCULATURE, 2014, 5 : 74 - 78
  • [42] Worsening of left ventricular ejection fraction induced by dipyridamole on Tl-201 gated myocardial perfusion imaging predicts significant coronary artery disease
    Hung G.-U.
    Lee K.-W.
    Chen C.-P.
    Yang K.-T.
    Lin W.-Y.
    Journal of Nuclear Cardiology, 2006, 13 (2) : 225 - 232
  • [43] Worsening of left ventricular ejection fraction induced by dipyridamole on TI-201 gated myocardial perfusion imaging predicts significant coronary artery disease
    Hung, GU
    Lee, KW
    Chen, CP
    Yang, KT
    Lin, WY
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (02) : 225 - 232
  • [44] Technologist corner: Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography
    Robert Pagnanelli
    Heidi Camposano
    Salvador Borges-Neto
    Journal of Nuclear Cardiology, 2017, 24 : 944 - 945
  • [45] Feasibility of myocardial dual-isotope perfusion imaging combined with gated single photon emission tomography for assessing coronary artery disease
    Fukuoka, S
    Maeno, M
    Nakagawa, S
    Fukunaga, T
    Yamada, H
    Eto, T
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (01) : 19 - 29
  • [46] Relationship of infarct size and severity versus left ventricular ejection fraction and volumes obtained from 99mTc-sestamibi gated single-photon emission computed tomography in patients treated with primary percutaneous coronary intervention
    Roberto Sciagrà
    Alessio Imperiale
    David Antoniucci
    Angela Migliorini
    Guido Parodi
    Giannetto Comis
    Alberto Pupi
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 969 - 974
  • [47] Relationship of infarct size and severity versus left ventricular ejection fraction and volumes obtained from 99mTc-sestamibi gated single-photon emission computed tomography in patients treated with primary percutaneous coronary intervention
    Sciagrà, R
    Imperiale, A
    Antoniucci, D
    Migliorini, A
    Parodi, G
    Comis, G
    Pupi, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (07) : 969 - 974
  • [48] "Picture-in-Picture" Artifact: Introduction and Characterization of a Hitherto Unrecognized Imaging Artifact in Creating Perfusion Defects in Myocardial Perfusion Single-Photon Emission Computed Tomography
    Qutbi, Mohsen
    Soltanshahi, Mehdi
    Gorzi, Saba Karami
    Shiravand, Yaser
    Haghi, Seyed Mojtaba Edalat
    Khosravi, Ali
    Asli, Isa Neshandar
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2021, 36 (01): : 69 - 72
  • [49] Left ventricular function parameters obtained from gated myocardial perfusion SPECT imaging: a comparison of two data processing systems
    Tout, DA
    Rogers, A
    Van Aswegen, A
    Underwood, SR
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (02) : 103 - 107
  • [50] Comparison of left ventricular shape by gated SPECT imaging in diabetic and nondiabetic patients with normal myocardial perfusion: A propensity score analysis
    Nappi, Carmela
    Gaudieri, Valeria
    Acampa, Wanda
    Assante, Roberta
    Zampella, Emilia
    Mainolfi, Ciro Gabriele
    Petretta, Mario
    Germano, Guido
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 394 - 403