Evaluation of a stochastic approach to 2D-3D intensity-based registration

被引:0
|
作者
Aouadi, S. [1 ]
Sarry, L. [1 ]
机构
[1] INSERM, ERIM ERI 14, F-63001 Clermont Ferrand, France
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
this paper assesses a new 2D-3D rigid registration method based on stochastic clustering and an enhanced estimator for mutual information. It combines precision, accuracy and acceptable computation time. Spine datasets (fluoroscopy and computed tomography) with their gold standard transformations are used. Both optimization method and similarity measure are assessed separately using standardized evaluation methodologies. Sub-millimeter accuracy and the high convergence rate obtained within one minute are compared to other quasi-global optimization processes such as particle filtering.
引用
收藏
页码:6388 / 6391
页数:4
相关论文
共 50 条
  • [21] Intensity-based 3D local image registration
    Song, Huajun
    Qiu, Peihua
    PATTERN RECOGNITION LETTERS, 2017, 94 : 15 - 21
  • [22] Accurate and precise 2D-3D registration based on X-ray intensity
    Aouadi, Souha
    Sarry, Laurent
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (01) : 134 - 151
  • [23] 2D-3D registration based on shape matching
    Cyr, CM
    Kamal, AF
    Sebastian, TB
    Kimia, BB
    IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, PROCEEDINGS, 2000, : 198 - 203
  • [24] Intensity-based similarity measures evaluation for CT to ultrasound 2D registration
    Sandoval, Z.
    Dillenseger, J. -L.
    IRBM, 2013, 34 (4-5) : 278 - 282
  • [25] A Computationally Efficient Approach for 2D-3D Image Registration
    Haque, Md. Nazmul
    Pickering, Mark R.
    Biswas, Moyuresh
    Frater, Michael R.
    Scarvell, Jennie M.
    Smith, Paul N.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6268 - 6271
  • [26] Analysis of forearm rotational motion using biplane fluoroscopic intensity-based 2D-3D matching
    Abe, Shingo
    Otake, Yoshito
    Tennma, Yusuke
    Hiasa, Yuta
    Oka, Kunihiro
    Tanaka, Hiroyuki
    Shigi, Atsuo
    Miyamura, Satoshi
    Sato, Yoshinobu
    Murase, Tsuyoshi
    JOURNAL OF BIOMECHANICS, 2019, 89 : 128 - 133
  • [27] An intensity-based registration algorithm for probabilistic images and its application for 2-D to 3-D image registration
    Rohlfing, T
    Russakoff, DB
    Murphy, MJ
    Maurer, CR
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 581 - 591
  • [28] Real-Time Intensity-Based Rigid 2D-3D Medical Image Registration Using RapidMind Multi-Core Development Platform
    Xu, Lin
    Wan, Justin W. L.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5382 - 5385
  • [29] A Saliency-based Framework for 2D-3D Registration
    Brown, Mark
    Guillemaut, Jean-Yves
    Windridge, David
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS (VISAPP), VOL 1, 2014, : 265 - 273
  • [30] A robust technique for 2D-3D registration
    Gong, Ren Hui
    Abolinaesumi, Purang
    Stewart, James
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 714 - 717