Response of Reinforced Concrete Buildings in Concepcion during the Maule Earthquake

被引:46
作者
Westenenk, Benjamin [1 ]
Carlos de la Llera, Juan [1 ]
Jose Besa, Juan [1 ]
Juenemann, Rosita [1 ]
Moehle, Jack [2 ]
Lueders, Carl [1 ]
Antonio Inaudi, Jose [3 ]
Elwood, Kenneth J. [4 ]
Hwang, Shyh-Jiann [5 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Santiago, Chile
[2] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA USA
[3] UNC, Dept Struct, Cordoba, Spain
[4] Univ British Columbia, Dept Civil Engn, Vancouver, BC, Canada
[5] Natl Taiwan Univ, Dept Civil Engn, Taipei 10764, Taiwan
基金
美国国家科学基金会;
关键词
Concrete buildings - Earthquakes - Reinforced concrete;
D O I
10.1193/1.4000037
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Detailed observations are reported for eight shear wall buildings from the Concepcion region that experienced severe damage during the 27 February 2010 Chile earthquake. The repetitive nature of some of the damage suggests that these field observations may be applicable to similar buildings elsewhere, whereas other damage may be unique. Several shear walls experienced failures that apparently started at the boundaries due to the high compression in these unconfined edges, and propagated into the wall web. Other walls, including horizontal and vertical wall segments in perforated walls, experienced shear failure. Damage also was observed in columns, beams, and coupling slabs. In most cases, the percentage of damaged elements was less than 10% of the lateral force-resisting elements of the building, suggesting that these structures were not capable of distributing damage. Several building indices are calculated, including vibration periods and regularity indices, for comparison with observed behavior. [DOI: 10.1193/1.4000037]
引用
收藏
页码:S257 / S280
页数:24
相关论文
共 14 条
[1]   DID THE LARGE COSEISMIC DISPLACEMENT CAUSE THE GLOBAL OVERTURNING COLLAPSE OF THE ALTO RIO BUILDING DURING THE 27 FEBRUARY 2010 OFFSHORE MAULE, CHILE EARTHQUAKE? [J].
Alimoradi, Arzhang ;
Naeim, Farzad .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2010, 19 (08) :876-884
[2]  
American Concrete Institute (ACT318), 1995, 31895 ACI
[3]  
[Anonymous], WORLD HOUSING ENCY
[4]  
[Anonymous], 1999, Recommended Lateral Force Requirements and Commentary
[5]  
BSSC, 2003, NEHRP REC PROV SEISM
[6]  
Bureau of Indian Standards, 2002, 1893 IS 1
[7]  
Computers and Structures Inc. (CSI), 2011, ETABS V9 6
[8]  
Guendelman T, 1997, P 7 CHIL C SEISM EAR
[9]  
Ingenieria DICTUC S.A. (DICTUC), 2010, EST EV DIAGN ESTR ED
[10]  
Instituto Nacional de Estadisticas de Chile (INE), 2010, INF BAS APPR BUILD P