Progressive Loss of Retinal Ganglion Cell Function Is Hindered with IOP-Lowering Treatment in Early Glaucoma

被引:30
作者
Ventura, Lori M. [1 ]
Feuer, William J. [1 ]
Porciatti, Vittorio [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, McKnight Vis Res Ctr, Miller Sch Med, Miami, FL 33136 USA
关键词
OCULAR HYPERTENSION TREATMENT; PATTERN ELECTRORETINOGRAM; INTRAOCULAR-PRESSURE; REDUCTION; PARADIGM; TIMOLOL;
D O I
10.1167/iovs.11-8525
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate progressive changes of retinal ganglion cell (RGC) function in glaucoma suspects before and after IOP-lowering treatment. METHODS. The authors retrospectively analyzed pattern electro-retinograms (PERG) recorded twice a year in 32 glaucoma suspects over at least 6 years. Fifteen patients (28 eyes in the study group) received IOP-lowering treatment at intermediate points during the follow-up, thereby generating a break point between the untreated period and the treated period. Seventeen patients (31 eyes in the control group) were not treated; a break point in the follow-up period was randomly assigned. To assess the effect of treatment, linear regression slopes of PERG amplitude were calculated for periods before and after the break point, and compared both within and between groups. Linear mixed models applied to raw PERG amplitudes recorded over the entire follow-up period were also calculated. RESULTS. Before the break point, slopes had a similar negative trend in both groups, whereas after the break point the slope became shallower in the treated group (P = 0.002). The linear mixed model revealed an interaction between groups, period relative to break point, and segment duration (P = 0.001). Both analyses agreed that after the break point, the rate of PERG amplitude decline slowed in treated eyes by 0.013-0.019 mu V/year compared with the untreated eyes. Mean IOPs measured before and after break point were similar in control eyes (14.8 +/- 3.20 vs. 14.8 +/- 3.14 mm Hg) but different in treated eyes (16.84 +/- 3.96 vs. 14.8 +/- 3.24 mm Hg; P < 0.001). CONCLUSIONS. Progressive loss of RGC function in early glaucoma may be alleviated after IOP lowering, as measured by PERG. (Invest Ophthalmol Vis Sci. 2012;53:659-663) DOI: 10.1167/iovs.11-8525
引用
收藏
页码:659 / 663
页数:5
相关论文
共 26 条
  • [1] Update on the pattern electroretinogram in glaucoma
    Bach, Michael
    Hoffmann, Michael B.
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (06) : 386 - 395
  • [2] Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography
    Bayer, AU
    Maag, KP
    Erb, C
    [J]. OPHTHALMOLOGY, 2002, 109 (07) : 1350 - 1361
  • [3] Diagnostic Accuracy of Pattern Electroretinogram Optimized for Glaucoma Detection
    Bowd, Chistopher
    Vizzeri, Gianmarco
    Tafreshi, Ali
    Zangwill, Linda M.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. OPHTHALMOLOGY, 2009, 116 (03) : 437 - 443
  • [4] Repeatability of Pattern Electroretinogram Measurements Using a New Paradigm Optimized for Glaucoma Detection
    Bowd, Christopher
    Tafreshi, Ali
    Vizzeri, Gianmarco
    Zangwill, Linda M.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (06) : 437 - 442
  • [5] Intraocular Pressure: Modulation as Treatment for Glaucoma
    Caprioli, Joseph
    Varma, Rohit
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (03) : 340 - 344
  • [6] PATTERN ELECTRORETINOGRAM IN TREATED OCULAR HYPERTENSION - A CROSS-SECTIONAL STUDY AFTER TIMOLOL MALEATE THERAPY
    COLOTTO, A
    SALGARELLO, T
    GIUDICEANDREA, A
    DELUCA, LA
    COPPE, A
    BUZZONETTI, L
    FALSINI, B
    [J]. OPHTHALMIC RESEARCH, 1995, 27 (03) : 168 - 177
  • [7] FALSINI B, 1992, CLIN VISION SCI, V7, P341
  • [8] Reproducibility of pattern electroretinogram in glaucoma patients with a range of severity of disease with the new glaucoma paradigm
    Fredette, Marie-Josee
    Anderson, Douglas R.
    Porciatti, Vittorio
    Feuer, William
    [J]. OPHTHALMOLOGY, 2008, 115 (06) : 957 - 963
  • [9] Improvement of spatial contrast sensitivity threshold after surgical reduction of intraocular pressure in unilateral high-tension glaucoma
    Gandolfi, SA
    Cimino, L
    Sangermani, C
    Ungaro, N
    Mora, P
    Tardini, MG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (01) : 197 - 201
  • [10] Gordon MO, 1999, ARCH OPHTHALMOL-CHIC, V117, P573