A molecularly imprinted sensor based on β-cyclodextrin incorporated multiwalled carbon nanotube and gold nanoparticles-polyamide amine dendrimer nanocomposites combining with water-soluble chitosan derivative for the detection of chlortetracycline

被引:68
作者
Lian, Wenjing [2 ]
Huang, Jiadong [3 ]
Yu, Jinghua [2 ]
Zhang, Xiuming [2 ]
Lin, Qing [2 ]
He, Xiaorui [2 ]
Xing, Xianrong [2 ]
Liu, Su [1 ]
机构
[1] Univ Jinan, Coll Resources & Environm, Jinan 250022, Peoples R China
[2] Univ Jinan, Coll Chem & Chem Engn, Jinan 250022, Peoples R China
[3] Univ Jinan, Coll Med & Life Sci, Jinan 250022, Peoples R China
关键词
Molecularly imprinted polymers; Chitosan derivative; beta-cyclodextrin-multiwalled carbon nanotube composites; Gold nanoparticles-polyamide amine dendrimer nanocomposites; Chlortetracycline detection; POLYMERS; ANTIBIOTICS; CHITIN; TETRACYCLINE; RECOGNITION; SEPARATION;
D O I
10.1016/j.foodcont.2012.02.023
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
We developed a molecularly imprinted electrochemical sensor based on gold electrode decorated by beta-cyclodextrin (CD) incorporated multiwalled carbon nanotube, gold nanoparticles-polyamide amine dendrimer nanocomposites (Au-PAMAM) and chitosan derivative (CSDT) for selective and convenient determination of chlortetracycline (CTC). The electrochemical sensor was fabricated by stepwise modification of cyclodextrin-multiwalled carbon nanotube composites (CD-MWCNTs) and Au-PAMAM onto the gold electrode. The layer of MIPs was the outer layer of the electrochemical sensor. In this article, CSDT acted as functional monomer, and CTC as the template molecule. Cyclic voltammetry (CV) and amperometry were used to characterize the electrochemical behavior of the developed sensor. The linear range of the molecularly imprinted sensor was from 9.00 x 10(-8) to 5.00 x 10(-5) mol/L (from 0.0464 mg/kg to 25.767 mg/kg), with the limit of detection (LOD) of 4.954 x 10(-8) mol/L (0.0255 mg/kg, S/N = 3). The developed sensor showed high selectivity and excellent stability toward CTC. The results from real sample analysis confirmed the applicability of the sensor to quantitative analysis. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 45 条
[1]   Management of antibiotic residues from agricultural sources: Use of composting to reduce chlortetracycline residues in beef manure from treated animals [J].
Arikan, Osman A. ;
Mulbry, Walter ;
Rice, Clifford .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 164 (2-3) :483-489
[2]   Molecularly imprinted polymers with specific recognition for macromolecules and proteins [J].
Bergmann, Nicole M. ;
Peppas, Nicholas A. .
PROGRESS IN POLYMER SCIENCE, 2008, 33 (03) :271-288
[3]  
CengIz M., 2010, Journal of Biological & Environmental Sciences, V4, P23
[4]   A new type of chitosan hydrogel sorbent generated by anionic surfactant gelation [J].
Chatterjee, Sudipta ;
Chatterjee, Tania ;
Woo, Seung H. .
BIORESOURCE TECHNOLOGY, 2010, 101 (11) :3853-3858
[5]  
Chen H. Y., 2005, BIOSENS BIOELECTRON, V211, P90
[6]   Validation of a high-performance liquid chromatography method for the determination of oxytetracycline, tetracycline, chlortetracycline and doxycycline in bovine milk and muscle [J].
Cinquina, AL ;
Longo, F ;
Anastasi, G ;
Giannetti, L ;
Cozzani, R .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :227-233
[7]   Chitosan-A versatile semi-synthetic polymer in biomedical applications [J].
Dash, M. ;
Chiellini, F. ;
Ottenbrite, R. M. ;
Chiellini, E. .
PROGRESS IN POLYMER SCIENCE, 2011, 36 (08) :981-1014
[8]   CRYSTAL STRUCTURE OF AUREOMYCIN (CHLORTETRACYCLINE) HYDROCHLORIDE - CONFIGURATION, BOND DISTANCES AND CONFORMATION [J].
DONOHUE, J ;
TRUEBLOOD, KN ;
WEBSTER, MS ;
DUNITZ, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1963, 85 (07) :851-&
[9]   Sensitive acetylcholinesterase biosensor based on assembly of β-cyclodextrins onto multiwall carbon nanotubes for detection of organophosphates pesticide [J].
Du, Dan ;
Wang, Minghui ;
Cai, Jie ;
Zhang, Aidong .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :337-341