Analysis of tear film breakup on Etafilcon A hydrogel lenses

被引:20
作者
Bruce, AS
Mainstone, JC
Golding, TR
机构
[1] Univ Melbourne, Victorian Coll Optometry, Melbourne, Vic 3053, Australia
[2] Univ Melbourne, Dept Optometry & Vis Sci, Carlton, Vic 3053, Australia
[3] Queensland Univ Technol, Sch Optometry, Ctr Eye Res, Kelvin Grove, Qld 4059, Australia
关键词
tear film breakup; tear film stability; tear film meniscus; hydrogel lens; Acuvue;
D O I
10.1016/S0142-9612(01)00162-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: There is a need to understand better the biomaterial characteristics responsible for tear film stability during hydrogel lens wear. The underlying cause of pre-lens tear film instability may be indicated by the distribution of sites of breakup. The purpose of this study was to compare the distribution of rupture sites during wear of a common biomaterial to that without lenses. Methods: A videokeratography unit, the Topographic Modeling System(TM), was used to capture an image of the tear film at the moment of breakup. Forty measurements were made for each of ten subjects, and the resultant rupture site distributions evaluated. The pre-lens tear film breakup locations were studied for Acuvue (Etafilcon A) disposable contact lenses using the same technique. Results: There was a statistically significant trend for pre-corneal tear film breaks to occur more commonly in parameniscal zones than in areas overlying the central cornea (ANOVA, p = 0.002). With the Etafilcon A lenses, a significant difference in breakup frequency between the two regions was not observed. Conclusions: The pre-corneal tear film findings are consistent with the meniscus model of tear film stability; however, the biomaterial surface characteristics of Etafilcon A give other factors a more dominant role in tear film rupture. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3249 / 3256
页数:8
相关论文
共 27 条
  • [1] Bitton E, 1998, ADV EXP MED BIOL, V438, P381
  • [2] RELIABILITY OF THE TEAR BREAK-UP TIME TECHNIQUE OF ASSESSING TEAR STABILITY AND THE LOCATIONS OF THE TEAR BREAK-UP IN HONG-KONG CHINESE
    CHO, P
    BROWN, B
    CHAN, I
    CONWAY, R
    YAP, M
    [J]. OPTOMETRY AND VISION SCIENCE, 1992, 69 (11) : 879 - 885
  • [3] In vivo tear-film thickness determination and implications for tear-film stability
    Creech, JL
    Do, LT
    Fatt, I
    Radke, CJ
    [J]. CURRENT EYE RESEARCH, 1998, 17 (11) : 1058 - 1066
  • [4] Dillehay S. M., 2000, CLIN MANUAL CONTACT, P239
  • [5] DOANE MG, 1988, T BRIT CONT LENS ASS, P110
  • [6] EFFECT OF HYDROGEL LENS WEAR ON TEAR FILM STABILITY
    FABER, E
    GOLDING, TR
    LOWE, R
    BRENNAN, NA
    [J]. OPTOMETRY AND VISION SCIENCE, 1991, 68 (05) : 380 - 384
  • [7] FATT I, 1991, CLAO Journal, V17, P267
  • [8] Golding TR, 1997, CORNEA, V16, P649
  • [9] CORNEAL DESICCATION STAINING WITH HYDROGEL LENSES - TEAR FILM AND CONTACT-LENS FACTORS
    GUILLON, JP
    GUILLON, M
    MALGOUYRES, S
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1990, 10 (04) : 343 - 350
  • [10] Guillon JP, 1998, ADV EXP MED BIOL, V438, P859