Ion-selective electrodes:: Polyaniline modification and anion recognition

被引:53
|
作者
Shishkanova, TV
Sapurina, I
Stejskal, J
Král, V
Volf, R
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague, Czech Republic
[2] Russian Acad Sci, Inst Macromol Cpds, St Petersburg 199004, Russia
[3] Acad Sci Czech Republ, Inst Macromol Chem, CR-16206 Prague, Czech Republic
关键词
ion-selective electrode; surface modification; polyaniline; anion recognition; conducting polymer;
D O I
10.1016/j.aca.2005.08.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel arrangement for polymeric membranes used in ion-selective electrodes is presented. The surface of a conventional plasticized poly(vinyl chloride) (PVC) membrane was coated with a chemically generated film of a conducting polymer, polyaniline (PANI). The effect of PANI on the anionic potentiometric response of PVC membranes derived from calix[4]pyrrole and tridodecylmethylammonium chloride (TDDMACI) is reported. Five different types of electrodes with the following membrane compositions were studied: (1) PVC/PANI (a reference experiment), (2) PVC + TDDMACI (as anion-exchanger)/PANI, (3) PVC + calix[4]pyrrole (as neutral carrier)/PANI, (4) PVC + calix[4]pyrrole + TDDMACI (uncoated membrane) and (5) PVC + calix[4]pyrrole + TDDMACl/PANI. Hydrophilicity of the uncoated and PANI-coated membrane surfaces was assessed by measurements of water contact angle, theta. In the protonated state, the neat PANI is more hydrophilic, theta = 49 degrees, than in its deprotonated base form, theta = 94 degrees. After surface deposition of thin PANI film, increased potentiometric sensitivity of the membranes, especially towards hydrophilic anions (F-, H2PO4-), was achieved. The distinct differences in the character of calix[4]pyrrole (neutral carrier) and TDDMACI (anion-exchanger) to sense anionic species were retained and became more pronounced. The PANI film may be regarded as a novel kind of an electrode modifier for anion-sensing. The role of the PANI film in the formation of the potentiometric response is discussed. It is proposed that the PANI film acts as an anion-exchanger. The transport of anions through a thin PANI film is also affected by the character of anions and by pH.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [31] Anti-fouling polymeric membrane ion-selective electrodes
    Qi, Longbin
    Liang, Rongning
    Jiang, Tianjia
    Qin, Wei
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 150
  • [32] Polysulfone as an alternative material to PVC in the design of ion-selective electrodes
    Gonzalez-Bellavista, Anna
    Macanas, Jorge
    Munoz, Maria
    Fabregas, Esteve
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (02) : 691 - 696
  • [33] Properties of ion-selective electrodes with polymeric membranes for ketoprofen determination
    J. Lenik
    Journal of Analytical Chemistry, 2012, 67 : 543 - 549
  • [34] Poly(vinyl chloride) ion-selective electrodes for Piribedil determination
    Issa, YM
    Hassouna, MM
    Abdel-Gawad, FM
    Hussien, EM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) : 493 - 502
  • [35] Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact
    Xianghua Zeng
    Wenwen Jiang
    Geoffrey I. N. Waterhouse
    Xiaohui Jiang
    Zhiming Zhang
    Liangmin Yu
    Microchimica Acta, 2021, 188
  • [36] DETERMINATION OF N-HALOGENO DERIVATIVES WITH ION-SELECTIVE ELECTRODES
    MARQUEZ, M
    ALVARADO, J
    DEROSA, M
    ANALYST, 1991, 116 (07) : 721 - 722
  • [37] Ion-selective electrodes with solid contact for heavy metals determination
    Wardak, C.
    Lenik, J.
    PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON HEAVY METALS IN THE ENVIRONMENT, 2013, 1
  • [38] Development of Flexible Ion-Selective Electrodes for Saliva Sodium Detection
    Lim, Hyo-Ryoung
    Lee, Soon Min
    Mahmood, Musa
    Kwon, Shinjae
    Kim, Yun-Soung
    Lee, Yongkuk
    Yeo, Woon-Hong
    SENSORS, 2021, 21 (05) : 1 - 11
  • [39] Cyproheptadine ion-selective electrodes and their applications in some pharmaceutical formulations
    Drozd, J
    Hopkala, H
    DESALINATION, 2004, 163 (1-3) : 119 - 125
  • [40] Enhancing ion-selective polymeric membrane electrodes by instrumental control
    Bakker, Eric
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 53 : 98 - 105