Ion-selective electrodes:: Polyaniline modification and anion recognition

被引:53
|
作者
Shishkanova, TV
Sapurina, I
Stejskal, J
Král, V
Volf, R
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague, Czech Republic
[2] Russian Acad Sci, Inst Macromol Cpds, St Petersburg 199004, Russia
[3] Acad Sci Czech Republ, Inst Macromol Chem, CR-16206 Prague, Czech Republic
关键词
ion-selective electrode; surface modification; polyaniline; anion recognition; conducting polymer;
D O I
10.1016/j.aca.2005.08.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel arrangement for polymeric membranes used in ion-selective electrodes is presented. The surface of a conventional plasticized poly(vinyl chloride) (PVC) membrane was coated with a chemically generated film of a conducting polymer, polyaniline (PANI). The effect of PANI on the anionic potentiometric response of PVC membranes derived from calix[4]pyrrole and tridodecylmethylammonium chloride (TDDMACI) is reported. Five different types of electrodes with the following membrane compositions were studied: (1) PVC/PANI (a reference experiment), (2) PVC + TDDMACI (as anion-exchanger)/PANI, (3) PVC + calix[4]pyrrole (as neutral carrier)/PANI, (4) PVC + calix[4]pyrrole + TDDMACI (uncoated membrane) and (5) PVC + calix[4]pyrrole + TDDMACl/PANI. Hydrophilicity of the uncoated and PANI-coated membrane surfaces was assessed by measurements of water contact angle, theta. In the protonated state, the neat PANI is more hydrophilic, theta = 49 degrees, than in its deprotonated base form, theta = 94 degrees. After surface deposition of thin PANI film, increased potentiometric sensitivity of the membranes, especially towards hydrophilic anions (F-, H2PO4-), was achieved. The distinct differences in the character of calix[4]pyrrole (neutral carrier) and TDDMACI (anion-exchanger) to sense anionic species were retained and became more pronounced. The PANI film may be regarded as a novel kind of an electrode modifier for anion-sensing. The role of the PANI film in the formation of the potentiometric response is discussed. It is proposed that the PANI film acts as an anion-exchanger. The transport of anions through a thin PANI film is also affected by the character of anions and by pH.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [1] Ion-Selective Electrodes Prepared with Polyaniline Membranes
    A. Aytaç
    M. Kabasakaloğlu
    B. Sarı
    M. Talu
    Russian Journal of Electrochemistry, 2004, 40 : 732 - 735
  • [2] Ion-selective electrodes prepared with polyaniline membranes
    Aytaç, A
    Kabasakaloglu, M
    Sari, B
    Talu, M
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2004, 40 (07) : 732 - 735
  • [3] The Theory of Ion-Selective Electrodes
    Ernö Pungor
    Analytical Sciences, 1998, 14 : 249 - 256
  • [4] The theory of ion-selective electrodes
    Pungor, E
    ANALYTICAL SCIENCES, 1998, 14 (02) : 249 - 256
  • [5] Perchlorate Selectivity of Anion Exchange Resins as Evaluated Using Ion-Selective Electrodes
    Kenji Yamamoto
    Shin’ya Mitsuda
    Naomi Ohtake
    Natsuki Murashige
    Satoshi Ohmuro
    Akio Yuchi
    Analytical Sciences, 2017, 33 : 159 - 163
  • [6] Perchlorate Selectivity of Anion Exchange Resins as Evaluated Using Ion-Selective Electrodes
    Yamamoto, Kenji
    Mitsuda, Shin'ya
    Ohtake, Naomi
    Murashige, Natsuki
    Ohmuro, Satoshi
    Yuchi, Akio
    ANALYTICAL SCIENCES, 2017, 33 (02) : 159 - 163
  • [7] The new wave of ion-selective electrodes
    Pretsch, Erno
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (01) : 46 - 51
  • [8] Stable Pb2+ ion-selective electrodes based on polyaniline-TiO2 solid contacts
    Zeng, Xianghua
    Jiang, Wenen
    Jiang, Xiaohui
    Waterhouse, Geoffrey I. N.
    Zhang, Zhiming
    Yu, Liangmin
    ANALYTICA CHIMICA ACTA, 2020, 1094 : 26 - 33
  • [9] Ion-selective electrodes for the determination of closoborate anions
    A. V. Kopytin
    K. Yu. Zhizhin
    Yu. I. Urusov
    V. N. Mustyatsa
    Yu. V. Kokunov
    N. T. Kuznetsov
    Journal of Analytical Chemistry, 2011, 66 : 666 - 669
  • [10] Ion-selective electrodes for the determination of closoborate anions
    Kopytin, A. V.
    Zhizhin, K. Yu.
    Urusov, Yu. I.
    Mustyatsa, V. N.
    Kokunov, Yu. V.
    Kuznetsov, N. T.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (07) : 666 - 669