Automated liver sampling using a gradient dual-echo Dixon-based technique

被引:9
作者
Bashir, Mustafa R. [1 ]
Dale, Brian M. [2 ]
Merkle, Elmar M. [1 ]
Boll, Daniel T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Siemens Med Solut, Cary, NC USA
关键词
liver MRI; automated sampling; segmentation; Dixon; ratio pair; FAT QUANTIFICATION; IN-VIVO; SEGMENTATION; DISEASE; BIOPSY; DECOMPOSITION; SPECTROSCOPY; VARIABILITY;
D O I
10.1002/mrm.23123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance spectroscopy of the liver requires input from a physicist or physician at the time of acquisition to insure proper voxel selection, while in multiecho chemical shift imaging, numerous regions of interest must be manually selected in order to ensure analysis of a representative portion of the liver parenchyma. A fully automated technique could improve workflow by selecting representative portions of the liver prior to human analysis. Complete volumes from three-dimensional gradient dual-echo acquisitions with two-point Dixon reconstruction acquired at 1.5 and 3 T were analyzed in 100 subjects, using an automated liver sampling algorithm, based on ratio pairs calculated from signal intensity image data as fat-only/water-only and log(in-phase/opposed-phase) on a voxel-by-voxel basis. Using different gridding variations of the algorithm, the average correct liver volume samples ranged from 527 to 733 mL. The average percentage of sample located within the liver ranged from 95.4 to 97.1%, whereas the average incorrect volume selected was 16.535.4 mL (2.94.6%). Average run time was 19.779.0 s. The algorithm consistently selected large samples of the hepatic parenchyma with small amounts of erroneous extrahepatic sampling, and run times were feasible for execution on an MRI system console during exam acquisition. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1469 / 1477
页数:9
相关论文
共 26 条
[1]  
Bashir MR, 2011, EUR J RADIOL 0215
[2]   Pilot Study Assessing Differentiation of Steatosis Hepatis, Hepatic Iron Overload, and Combined Disease Using Two-Point Dixon MRI at 3 T: In Vitro and In Vivo Results of a 2D Decomposition Technique [J].
Boll, Daniel T. ;
Marin, Daniele ;
Redmon, Grace M. ;
Zink, Stephen I. ;
Merkle, Elmar M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :964-971
[3]  
Brunt Elizabeth M, 2002, Clin Liver Dis, V6, P399, DOI 10.1016/S1089-3261(02)00002-8
[4]   Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359
[5]  
Diehl A M, 1997, Liver Transpl Surg, V3, P206, DOI 10.1053/jlts.1997.v3.ajlts0030206
[6]   Liver and spleen volumetry with quantitative MR imaging and dual-space clustering segmentation [J].
Farraher, SW ;
Jara, H ;
Chang, KJ ;
Hou, A ;
Soto, JA .
RADIOLOGY, 2005, 237 (01) :322-328
[7]  
Forgione A, 2007, Minerva Gastroenterol Dietol, V53, P83
[8]   Automatic liver segmentation technique for three-dimensional visualisation of CT data [J].
Gao, LM ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 201 (02) :359-364
[9]   A fully automatic three-step liver segmentation method on LDA-based probability maps for multiple contrast MR images [J].
Gloger, Oliver ;
Kuehn, Jens ;
Stanski, Adam ;
Voelzke, Henry ;
Puls, Ralf .
MAGNETIC RESONANCE IMAGING, 2010, 28 (06) :882-897
[10]   Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification [J].
Hamilton, Gavin ;
Middleton, Michael S. ;
Bydder, Mark ;
Yokoo, Takeshi ;
Schwimmer, Jeffrey B. ;
Kono, Yuko ;
Patton, Heather M. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) :145-152