A novel self-expanding primarily bioabsorbable braided flow-diverting stent for aneurysms: initial safety results

被引:27
作者
Jamshidi, Mehdi [1 ]
Rajabian, Mahmoud [2 ]
Avery, Michael B. [3 ]
Sundararaj, Uttandaraman [4 ]
Ronsky, Janet [5 ]
Belanger, Brooke [6 ]
Wong, John H. [6 ]
Mitha, Alim P. [1 ,6 ]
机构
[1] Univ Calgary, Schulich Sch Engn, Biomed Engn, Calgary, AB, Canada
[2] Univ Calgary, Fac Med, MIF Microscopy & Imaging Facil, Calgary, AB, Canada
[3] Univ Calgary, Clin Neurosci, Calgary, AB, Canada
[4] Univ Calgary, Chem & Petr Engn, Calgary, AB, Canada
[5] Univ Calgary, Mech & Mfg Engn, Calgary, AB, Canada
[6] Univ Calgary, Cumming Sch Med, Clin Neurosci, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
aneurysm; artery; blood flow; flow diverter; stent; SCAFFOLD; THROMBOSIS; DEVICE;
D O I
10.1136/neurintsurg-2019-015555
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Introduction The advent of metal flow-diverting stents has provided neurointerventionalists with an option for treating aneurysms without requiring manipulations within the aneurysm sac. The large amount of metal in these stents, however, can lead to early and late thrombotic complications, and thus requires long-term antiplatelet agents. Bioabsorbable stents have been postulated to mitigate the risk of these complications. Here we present early data on the first self-expandable primarily bioabsorbable stent for aneurysms. Methods Braided stents were developed using poly-L-lactic acid fibers with material surface area similar to metal flow diverters. Crush resistance force, hemolysis, and thrombogenicity were determined and compared with existing commercial devices. Stents were deployed in infra-renal rabbit aortas to determine angiographic side branch patency and to study neointima formation for a 1-month follow-up period. Results Crush resistance force was determined to be on the order of existing commercial devices. Hemolytic behavior was similar to existing metal devices, and thrombogenicity was lower than metal flow-diverting stents. A smooth neointimal layer was found over the absorbable stent surface and all covered side branches were patent at follow-up. Conclusion The design of self-expanding primarily bioabsorbable flow-diverting stents is possible, and preliminary safety data is consistent with a favorable profile in terms of mechanical behavior, hemocompatibility, side branch patency, and histological effects. Additional in vitro and long-term in vivo studies are in progress and will help determine aneurysm occlusion rates and absorption characteristics of the stent.
引用
收藏
页码:700 / 705
页数:6
相关论文
共 22 条
[1]   EVALUATION OF POLY(L-LACTIC ACID) AS A MATERIAL FOR INTRAVASCULAR POLYMERIC STENTS [J].
AGRAWAL, CM ;
HAAS, KF ;
LEOPOLD, DA ;
CLARK, HG .
BIOMATERIALS, 1992, 13 (03) :176-182
[2]   Bioresorbable Vascular Scaffolds in Interventional Neuroradiology [J].
Arat, Anil ;
Daglioglu, Ergun ;
Akmangit, Ilkay ;
Peker, Ahmet ;
Arsava, Murat ;
Topcuoglu, Mehmet Akif ;
Belen, Deniz .
CLINICAL NEURORADIOLOGY, 2018, 28 (04) :585-592
[3]   Pipeline for uncoilable or failed aneurysms: 3-year follow-up results [J].
Becske, Tibor ;
Potts, Matthew B. ;
Shapiro, Maksim ;
Kallmes, David F. ;
Brinjikji, Waleed ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
JOURNAL OF NEUROSURGERY, 2017, 127 (01) :81-88
[4]   Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent [J].
Garcia, A. ;
Pena, E. ;
Martinez, M. A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 10 :166-175
[5]   In vivo evaluation of a new bioabsorbable self-expanding biliary stent [J].
Ginsberg, G ;
Cope, C ;
Shah, J ;
Martin, T ;
Carty, A ;
Habecker, P ;
Kaufmann, C ;
Clerc, C ;
Nuutinen, JP ;
Törmälä, P .
GASTROINTESTINAL ENDOSCOPY, 2003, 58 (05) :777-784
[6]   Bioresorbable vascular scaffolds - basic concepts and clinical outcome [J].
Indolfi, Ciro ;
De Rosa, Salvatore ;
Colombo, Antonio .
NATURE REVIEWS CARDIOLOGY, 2016, 13 (12) :719-729
[7]  
Jamshidi M, 2019, DEV BIOABSORBABLE BR
[8]  
Joost DV, 2013, STROKE, V44, P1567
[9]   Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds Evidence From a Network Meta-Analysis of 147 Trials [J].
Kang, Si-Hyuck ;
Chae, In-Ho ;
Park, Jin-Joo ;
Lee, Hak Seung ;
Kang, Do-Yoon ;
Hwang, Seung-Sik ;
Youn, Tae-Jin ;
Kim, Hyo-Soo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (12) :1203-1212
[10]   Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings [J].
Kolandaivelu, Kumaran ;
Swaminathan, Rajesh ;
Gibson, William J. ;
Kolachalama, Vijaya B. ;
Nguyen-Ehrenreich, Kim-Lien ;
Giddings, Virginia L. ;
Coleman, Leslie ;
Wong, Gee K. ;
Edelman, Elazer R. .
CIRCULATION, 2011, 123 (13) :1400-1409