Optimal pressure conditions for unbiased external ion accumulation in a two-dimensional radio-frequency quadrupole for Fourier transform ion cyclotron resonance mass spectrometry

被引:10
作者
Belov, ME [1 ]
Gorshkov, MV [1 ]
Alving, K [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1002/rcm.459
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When combined with on-line separations (e.g., capillary liquid chromatography (LC)), Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) provides a powerful tool for biological applications, and particularly proteomic studies. The sensitivity, dynamic range, and duty cycle provided by FTICR-MS have been shown to be increased by ion trapping and accumulation in a two-dimensional (2D) radio-frequency (rf)-only multipole positioned externally to an FTICR cell. However, it is important that ions be detected across the desired m/z range without a significant bias. In this work we found that pressure inside the accumulation rf-quadrupole plays an important role in obtaining 'unbiased' ion accumulation. Pressure optimization was performed in both pulsed and continuous modes. It was found that unbiased accumulation in a 2D rf-only quadrupole could be achieved in the pressure range of 5 X 10(-4) to 5 x 10 (-3) Torr. External ion accumulation performed at the optimal pressure resulted in an increase in both the spectrum acquisition rates and dynamic range. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1988 / 1996
页数:9
相关论文
共 28 条
[1]  
Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
[2]   Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins [J].
Belov, ME ;
Gorshkov, MV ;
Udseth, HR ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2271-2279
[3]   A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Belov, ME ;
Nikolaev, EN ;
Alving, K ;
Smith, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1172-1180
[4]   Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Harkewicz, R ;
Masselon, CD ;
Alving, K ;
Smith, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :205-225
[5]   Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Auberry, KJ ;
Harkewicz, R ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) :38-48
[6]   Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Udseth, HR ;
Conrads, TP ;
Veenstra, TD ;
Masselon, CD ;
Gorshkov, MV ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :253-261
[7]  
BELOV ME, 2001, IN PRESS J AM SOC MA
[8]  
Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
[9]  
2-8
[10]  
DAWSON PH, 1976, QUADRUPOLE MASS SPEC, P76