An Experimental Study on Shrinkage Strains of Normal-and High-Strength Concrete-Filled Frp Tubes

被引:3
作者
Vincent, Thomas [1 ]
Ozbakkaloglu, Togay [2 ]
机构
[1] Flinders Univ S Australia, Sch Comp Sci Engn & Math, Adelaide, SA 5042, Australia
[2] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
来源
INTERNATIONAL CONFERENCE ON MATERIALS SCIENCES AND NANOMATERIALS | 2017年 / 230卷
关键词
AXIAL COMPRESSIVE BEHAVIOR; SEISMIC PERFORMANCE; CONFINED CONCRETE; COLUMNS; SQUARE;
D O I
10.1088/1757-899X/230/1/012007
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
It is now well established that concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs) are an attractive construction technique for new columns, however studies examining concrete shrinkage in CFFTs remain limited. Concrete shrinkage may pose a concern for CFFTs, as in these members the curing of concrete takes place inside the FRP tube. This paper reports the findings from an experimental study on concrete shrinkage strain measurements for CFFTs manufactured with normal-and high-strength concrete (NSC and HSC). A total of 6 aramid FRP (AFRP)-confined concrete specimens with circular cross-sections were manufactured, with 3 specimens each manufactured using NSC and HSC. The specimens were instrumented with surface and embedded strain gauges to monitor shrinkage development of exposed concrete and concrete sealed inside the CFFTs, respectively. All specimens were cylinders with a 152 mm diameter and 305 mm height, and their unconfined concrete strengths were 44.8 or 83.2 MPa. Analysis of the shrinkage measurements from concrete sealed inside the CFFTs revealed that embedment depth and concrete compressive strength only had minor influences on recorded shrinkage strains. However, an analysis of shrinkage measurements from the exposed concrete surface revealed that higher amounts of shrinkage can occur in HSC. Finally, it was observed that shrinkage strains are significantly higher for concrete exposed at the surface compared to concrete sealed inside the CFFTs.
引用
收藏
页数:6
相关论文
共 30 条
  • [1] Compressive behavior of concrete externally confined by composite jackets. Part A: experimental study
    Berthet, JF
    Ferrier, E
    Hamelin, P
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2005, 19 (03) : 223 - 232
  • [2] Influence of key parameters on drying shrinkage of cementitious materials
    Bissonnette, B
    Pierre, P
    Pigeon, M
    [J]. CEMENT AND CONCRETE RESEARCH, 1999, 29 (10) : 1655 - 1662
  • [3] Corner strengthening of square and rectangular concrete-filled FRP tubes
    Chen, Linpeng
    Ozbakkaloglu, Togay
    [J]. ENGINEERING STRUCTURES, 2016, 117 : 486 - 495
  • [4] Fam A.Z., 2001, ACI STRUCT J, V98
  • [5] Behavior of square fiber reinforced polymer-high-strength concrete-steel double-skin tubular columns under combined axial compression and reversed-cyclic lateral loading
    Idris, Yunita
    Ozbakkaloglu, Togay
    [J]. ENGINEERING STRUCTURES, 2016, 118 : 307 - 319
  • [6] Seismic Behavior of High-Strength Concrete-Filled FRP Tube Columns
    Idris, Yunita
    Ozbakkaloglu, Togay
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (06)
  • [7] Analysis-oriented stress-strain models for FRP-confined concrete
    Jiang, T.
    Teng, J. G.
    [J]. ENGINEERING STRUCTURES, 2007, 29 (11) : 2968 - 2986
  • [8] Concrete confined by FRP material: a plasticity approach
    Karabinis, AI
    Rousakis, TC
    [J]. ENGINEERING STRUCTURES, 2002, 24 (07) : 923 - 932
  • [9] Testing and modeling of a novel FRP-encased steel-concrete composite column
    Karimi, Kian
    Tait, Michael J.
    El-Dakhakhni, Wael W.
    [J]. COMPOSITE STRUCTURES, 2011, 93 (05) : 1463 - 1473
  • [10] Kwan A, 2010, HKIE T, V17, P25