Quantitative assessment of articular cartilage degeneration using 3D ultrashort echo time cones adiabatic T1ρ (3D UTE-Cones-AdiabT1ρ) imaging

被引:5
作者
Wu, Mei [1 ,2 ]
Ma, Ya-Jun [2 ]
Liu, Mouyuan [3 ]
Xue, Yanping [2 ]
Gong, Lillian [2 ]
Wei, Zhao [2 ]
Jerban, Saeed [2 ]
Jang, Hyungseok [2 ]
Chang, Douglas G. [4 ]
Chang, Eric Y. [2 ,5 ]
Ma, Liheng [3 ]
Du, Jiang [2 ]
机构
[1] South China Univ Technol, Sch Med, Guangzhou Peoples Hosp 1, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, San Diego, CA 92037 USA
[3] Guangdong Pharmaceut Univ, Affiliated Hosp 1, Imaging Dept, Guangzhou, Guangdong, Peoples R China
[4] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92103 USA
[5] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
关键词
Ultrashort echo time; AdiabT(1 rho); Articular cartilage; Degeneration; Quantitative assessment; ROTATING-FRAME RELAXATION; OSTEOARTHRITIS; KNEE; MRI; VALIDATION; T-2-RHO; T-2;
D O I
10.1007/s00330-022-08722-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate articular cartilage degeneration using quantitative three-dimensional ultrashort-echo-time cones adiabatic-T-1 rho (3D UTE-Cones-AdiabT(1 rho)) imaging. Methods Sixty-six human subjects were recruited for this study. Kellgren-Lawrence (KL) grade and Whole-Organ MagneticResonance-Imaging Score (WORMS) were evaluated by two musculoskeletal radiologists. The human subjects were categorized into three groups, namely normal controls (KL0), doubtful-minimal osteoarthiitis (OA) (KL1-2), and moderate-severe OA (KL3-4). WORMS were regrouped to encompass the extent of lesions and the depth of lesions. The UTE-Cones-AdiabT(1 rho) values were obtained using 3D UTE-Cones data acquisitions preceded by seven paired adiabatic full passage pulses that corresponded to seven spin-locking times (TSLs) of 0, 12, 24, 36, 48, 72, and 96 ms. The performance of the UTE-Cones-AdiabT(1 rho) technique in evaluating the degeneration of knee cartilage was assessed via the ANOVA comparisons with subregional analysis and Spearman's correlation coefficient as well as the receiver-operating-characteristic (ROC) curve. Results UTE-Cones-AdiabT(1 rho) showed significant positive correlations with KL grade (r = 0.15, p < 0.05) and WORMS (r = 0.57, p < 0.05). Higher UTE-Cones-AdiabT(1 rho) values were observed in both larger and deeper lesions in the cartilage. The differences in UTE-Cones-AdiabT(1 rho) values among different extent and depth groups of cartilage lesions were all statistically significant (p < 0.05). Subregional analyses showed that the correlations between UTE-Cones-AdiabT(1 rho) and WORMS varied with the location of cartilage. The AUC value of UTE-Cones-AdiabT(1 rho) for mild cartilage degeneration (WORMS=1) was 0.8. The diagnostic threshold value of UTE-Cones-AdiabT(1 rho) for mild cartilage degeneration was 39.4 ms with 80.8% sensitivity. Conclusions The 3D UTE-Cones-AdiabT(1 rho) sequence can be useful in quantitative evaluation of articular cartilage degeneration.
引用
收藏
页码:6178 / 6186
页数:9
相关论文
共 50 条
  • [31] Volumetric mapping of bound and pore water as well as collagen protons in cortical bone using 3D ultrashort echo time cones MR imaging techniques
    Jerban, Saeed
    Ma, Yajun
    Li, Liang
    Jang, Hyungseok
    Wan, Lidi
    Guo, Tan
    Searleman, Adam
    Chang, Eric Y.
    Du, Jiang
    BONE, 2019, 127 : 120 - 128
  • [32] Weighted subtraction in 3D ultrashort echo time (UTE) imaging for visualization of short T2 tissues of the knee
    Lee, Young Han
    Kim, Sungjun
    Song, Ho-Taek
    Kim, InSeong
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2014, 55 (04) : 454 - 461
  • [33] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [34] High contrast cartilaginous endplate imaging using a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence
    Lombardi, Alecio F.
    Wei, Zhao
    Wong, Jonathan
    Carl, Michael
    Lee, Roland R.
    Wallace, Mark
    Masuda, Koichi
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2021, 34 (10)
  • [35] Knee menisci segmentation and relaxometry of 3D ultrashort echo time cones MR imaging using attention U-Net with transfer learning
    Byra, Michal
    Wu, Mei
    Zhang, Xiaodong
    Jang, Hyungseok
    Ma, Ya-Jun
    Chang, Eric Y.
    Shah, Sameer
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 1109 - 1122
  • [36] Whole knee joint T1 values measured in vivo at 3T by combined 3D ultrashort echo time cones actual flip angle and variable flip angle methods
    Ma, Ya-Jun
    Zhao, Wei
    Wan, Lidi
    Guo, Tan
    Searleman, Adam
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1634 - 1644
  • [37] Reversed Laminar Appearance of Articular Cartilage by T1-Weighting in 3D Fat-Suppressed Spoiled Gradient Recalled Echo (SPGR) Imaging
    Xia, Yang
    Zheng, Shaokuan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 733 - 737
  • [38] Significant correlations between human cortical bone mineral density and quantitative susceptibility mapping (QSM) obtained with 3D Cones ultrashort echo time magnetic resonance imaging (UTE-MRI)
    Jerban, Saeed
    Lu, Xing
    Jang, Hyungseok
    Ma, Yajun
    Namiranian, Behnam
    Le, Nicole
    Li, Ying
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2019, 62 : 104 - 110
  • [39] Fast T1 measurement of cortical bone using 3D UTE actual flip angle imaging and single-TR acquisition (3D UTE-AFI-STR)
    Wei, Zhao
    Jang, Hyungseok
    Bydder, Graeme M.
    Yang, Wenhui
    Ma, Ya-Jun
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3290 - 3298
  • [40] Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3 T system scientific research
    Milewski, Matthew D.
    Smitaman, Edward
    Moukaddam, Hicham
    Katz, Lee D.
    Essig, David A.
    Medvecky, Michael J.
    Haims, Andrew H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1637 - 1643