Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis

被引:3
|
作者
Territo, Paul R. [1 ]
Riley, Amanda A. [1 ]
McCarthy, Brian P. [1 ]
Hutchins, Gary D. [1 ]
机构
[1] Indiana Univ Sch Med, Dept Radiol & Imaging Sci, 950 W Walnut St,R2 E124, Indianapolis, IN 46202 USA
来源
EJNMMI PHYSICS | 2016年 / 3卷 / 01期
关键词
Cardiac output; PET; View-sharing; Kinetic modeling; SMALL-ANIMAL PET; REPORTER GENE-EXPRESSION; CARDIAC-OUTPUT; PERFORMANCE EVALUATION; BLOOD-FLOW; SCANNER; RAT;
D O I
10.1186/s40658-016-0161-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using F-18-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x - 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x - 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 +/- 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (-155 +/- 7.1 beats/min, p < 0.001, n = 4) and cardiac output (-75.9 +/- 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.
引用
收藏
页数:8
相关论文
共 5 条
  • [1] Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis
    Paul R. Territo
    Amanda A. Riley
    Brian P. McCarthy
    Gary D. Hutchins
    EJNMMI Physics, 3
  • [2] A COMPUTER-SIMULATION STUDY ON THE EFFECTS OF INPUT FUNCTION MEASUREMENT NOISE IN TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY (PET)
    FENG, DG
    WANG, XM
    COMPUTERS IN BIOLOGY AND MEDICINE, 1993, 23 (01) : 57 - 68
  • [3] Measurement of myocardial glucose uptake in patients with ischemic cardiomyopathy: Application of a new quantitative method using regional tracer kinetic information
    Wiggers, H
    Bottcher, M
    Nielsen, TT
    Gjedde, A
    Botker, HE
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (08) : 1292 - 1300
  • [4] A novel weighted least squares PET image reconstruction method using adaptive variable index sets
    Zhu, HQ
    Zhou, J
    Shu, HZ
    Luo, LM
    DIGITAL SIGNAL PROCESSING, 2006, 16 (02) : 106 - 119
  • [5] A Novel Method to Improve Image Quality for 2-D Small Animal PET Reconstruction by Correcting a Monte Carlo-Simulated System Matrix Using an Artificial Neural Network
    Su, Kuan-Hao
    Wu, Liang-Chih
    Lee, Jih-Shian
    Liu, Ren-Shyan
    Chen, Jyh-Cheng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 704 - 714