Development of ABS resin pellet certified reference materials for heavy metal analysis with respect to RoHS directive

被引:14
作者
Ohata, Masaki [1 ]
Kurahashi, Masayasu [1 ]
Hioki, Akiharu [1 ]
机构
[1] NMIJ, Inorgan Stand Sect, Inorgan Analyt Chem Div, AIST, Tsukuba, Ibaraki 3058563, Japan
关键词
ABS resin pellet CRMs; RoHS; ICP-MS; ICP-OES; isotope dilution mass spectrometry;
D O I
10.2116/bunsekikagaku.57.417
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ABS resin pellet certified reference materials (CRMs, NMIJ CRM 8102-a, 8103-a, 8112-a and 8113-a) were developed in this study. Both the sample pretreatment procedure and the measurement one for the determinations of Cd, Cr, Hg and Pb in candidate ABS resin pellet RMs were examined, and several analytical methods, including isotope dilution mass spectrometry (a primary method of measurement), were developed. The analytical results obtained by several analytical methods showed good agreement within the uncertainty estimated for each analytical method. Consequently, it is concluded that these analytical methods established for the determinations of Cd, Cr, Hg and Pb in this study are reliable with high accuracy. From these results, the ABS resin CRMs developed in this study are SI traceable and have international consistency.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 8 条
[1]  
*BIPM IEC IFCC ISO, 1993, GUID EXPR UNC MEAS
[2]   Atomic weights of the elements:: Review 2000 -: (IUPAC technical report) [J].
De Laeter, JR ;
Böhlke, JK ;
De Bièvre, P ;
Hidaka, H ;
Peiser, HS ;
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 2003, 75 (06) :683-800
[3]   Development of a modified medium pressure microwave vapor-phase digestion method for difficult to digest organic samples [J].
Eilola, K ;
Perämäki, P .
ANALYST, 2003, 128 (02) :194-197
[4]   Collaborative study to improve the quality control of trace element determinations in polymers. Part 2. Certification of polyethylene reference materials (CRMs 680 and 681) for As, Br, Cd, Cl, Cr, Hg, Pb, and S content [J].
Lamberty, A ;
Van Borm, W ;
Quevauviller, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (07) :811-818
[5]   Certified reference materials for the quality control of inorganic analyses of manufactured products (glass, polymers, paint coatings) [J].
Quevauviller, P .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (08) :446-456
[6]  
Van Borm W, 1999, FRESEN J ANAL CHEM, V365, P361
[7]   Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM) project using isotope dilution mass spectrometry [J].
Vogl, J ;
Liesegang, D ;
Ostermann, M ;
Diemer, J ;
Berglund, M ;
Quétel, CR ;
Taylor, PDP ;
Heumann, KG .
ACCREDITATION AND QUALITY ASSURANCE, 2000, 5 (08) :314-324
[8]  
2001, BUNSEKI, P114