Caeruloplasmin oxidase activity: measurement in serum by use of o-dianisidine dihydrochloride on a microplate reader

被引:11
作者
Stepien, Karolina M. [1 ]
Guy, Mark [1 ]
机构
[1] Salford Royal NHS Fdn Trust, Dept Clin Biochem, Stott Lane, Salford M6 8HD, Lancs, England
关键词
Caeruloplasmin; oxidative activity; enzymatic assay; Wilson's disease; free copper index; WILSONS-DISEASE; ASSAY;
D O I
10.1177/0004563217695350
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background The enzymatic method of caeruloplasmin measurement is based on copper-dependent oxidase activity. The advantage of the oxidase determination is that it has a much lower detection limit compared with immunoassay-based methods. It has found its application in both the diagnosis of Wilson's disease and also in the monitoring of patients' response to treatment. Methods The method previously described in literature was adapted for use on a 96-well plate. Caeruloplasmin oxidase activity results were derived from the equation: caeruloplasmin oxidase activity=(A(15)-A(5))x185U/L. Results Repeatability (intra-batch) imprecision ranged from 6 to 15% and intermediate (inter-batch) imprecision varied from 7 to 16% for caeruloplasmin oxidative activities of 14, 29, 45 and 99U/L. Between 3 and 92U/L, the assay appeared linear with a regression coefficient R-2=0.9958. The lower limit of quantification was 4U/L. Samples were stable over a five-week period at 4? and for at least four freeze-thaw cycles. There was a statistically significant difference between the areas under ROC curve for copper-to-caeruloplasmin ratios between caeruloplasmin oxidative activity and immunoassay-based methods (P<0.0171). The reference interval for caeruloplasmin activity was determined to be 12-166U/L. Conclusions Using the oxidative assay provides a cost-effective means of estimating caeruloplasmin concentrations. The method is easily adaptable to a 96-well plate format that facilitates high throughput of samples in a busy laboratory. The enzymatic method is more sensitive and specific for differentiating between Wilson's and non-Wilson's when compared with immunoassay-based methods.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 16 条
  • [1] Beetham R, 2006, ANN CLIN BIOCH, V43, P53
  • [2] AUTOMATED-ASSAY OF CERULOPLASMIN BY KINETIC-ANALYSIS OF ORTHO-DIANISIDINE OXIDATION
    BOYETT, JD
    LEHMANN, HP
    BEELER, MF
    [J]. CLINICA CHIMICA ACTA, 1976, 69 (02) : 233 - 241
  • [3] Burtis CA, 2012, TIETZ TXB CLIN CHEM, P509
  • [4] Usefulness of ferroxidase activity of ceruloplasmin in the diagnosis of Wilson's disease
    Fleming J.J.
    Santhosh S.
    Selvakumar R.
    Jose A.
    Eapen C.E.
    [J]. Indian Journal of Clinical Biochemistry, 2009, 24 (1) : 15 - 22
  • [5] GIBBS K, 1979, Q J MED, V48, P447
  • [6] INVESTIGATIONS IN SERUM COPPER .2. ISOLATION OF THE COPPER CONTAINING PROTEIN, AND A DESCRIPTION OF SOME OF ITS PROPERTIES
    HOLMBERG, CG
    LAURELL, CB
    [J]. ACTA CHEMICA SCANDINAVICA, 1948, 2 (07): : 550 - 556
  • [7] Value of an enzymatic assay for the determination of serum ceruloplasmin
    MacIntyre, G
    Gutfreund, KS
    Martin, WRW
    Camicioli, R
    Cox, DW
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2004, 144 (06): : 294 - 301
  • [8] Serum ceruloplasmin oxidase activity is a sensitive and highly specific diagnostic marker for Wilson's disease
    Merle, Uta
    Eisenbach, Christoph
    Weiss, Karl Heinz
    Tuma, Sabine
    Stremmel, Wolfgang
    [J]. JOURNAL OF HEPATOLOGY, 2009, 51 (05) : 925 - 930
  • [9] MUKERJEE H, 1990, CLIN CHEM, V36, P391
  • [10] SCHOSINSKY KH, 1974, CLIN CHEM, V20, P1556