Greenhouse Heating Technology Development by Using Riverbank Filtration Water Source Heat Pump

被引:0
作者
Moon, J. P. [1 ]
Lee, S. H. [1 ]
Kang, G. C. [1 ]
Kwon, J. K. [1 ]
Kang, Y. K. [1 ]
Lee, S. J. [1 ]
Kim, C. K. [1 ]
Cho, Y. [2 ]
机构
[1] Natl Acad Agr Sci, Dept Energy & Environm Engn, Suwon, South Korea
[2] K Water Inst, Technol Res Ctr, Taejon, South Korea
来源
INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013 | 2014年 / 1037卷
关键词
riverbank filtration water source heat pump; greenhouse heating performance; COPh; COPS; thermal tank; SYSTEM;
D O I
暂无
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
In order to heat greenhouses nearby river channels, a riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. An improved Recharging system, a thermal storage tank with separating insulation plate and a filtering tank for eliminating iron and manganese were developed to increase the coefficient of performance (COP) of heat pump. A heating system using riverbank filtration water source heat pump was installed at the paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as part of temperature keeping and heat insulation with a greenhouse area of 3,185 m(2). 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Oct. 15, 2011 to Feb. 29, 2012. As a result, the COPh of the heat pump was measured in the range of 3.5 similar to 4.0, while COPS of the system was represented as 3.0 similar to 3.5 COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a green house. Also, the recharging rate was constantly maintained at 60% of intake water.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 9 条
  • [1] A raw water source heat pump air-conditioning system
    Cho, Yong
    Yun, Rin
    [J]. ENERGY AND BUILDINGS, 2011, 43 (11) : 3068 - 3073
  • [2] Ground source heat pump - description and preliminary results of the Eco House system
    Doherty, PS
    Al-Huthaill, S
    Riffat, SB
    Abodahab, N
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (17-18) : 2627 - 2641
  • [3] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753
  • [4] Hwang K.S., 2006, P 2006 SUMM ANN C SO, P1186
  • [5] Kim H.S., 2006, P 2006 SUMM ANN C SO, P209
  • [6] Lee Dongkee, 2004, [The journal of Engineering Geology, 지질공학], V14, P391
  • [7] Lim H.J., 2009, KOREAN J AIR CONDITI, V21, P468
  • [8] Moon J.P., 2011, ASABE PUBLICATION
  • [9] Ryou Y.S., 2008, P 2008 SPRING ANN C, P630