Optimization of Data Acquisition and Sample Preparation Methods for LC-MS Urine Metabolomic Analysis

被引:2
|
作者
Skibinski, Robert [1 ]
Komsta, Lukasz [1 ]
机构
[1] Med Univ Lublin, Pharmaceut Fac, Dept Med Chem, PL-20090 Lublin, Poland
来源
OPEN CHEMISTRY | 2015年 / 13卷 / 01期
关键词
UHPLC; Q-TOF; MS/MS; fast polarity switching; metabolomics; INK WASTE-WATER; FLOCCULATION; COAGULATION;
D O I
10.1515/chem-2015-0096
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nowadays, chromatographic methods coupled with mass spectrometry are the most commonly used tools in metabolomics studies. These methods are currently being developed and various techniques and strategies are proposed for the profiling analysis of biological samples. However, the most important thing used to maximize the number of entities in the recorded profiles is the optimization of sample preparation procedure and the data acquisition method. Therefore, ultra high performance liquid chromatography coupled with accurate quadrupole-time-of-flight (Q-TOF) mass spectrometry was used for the comparison of urine metabolomic profiles obtained by the use of various spectral data acquisition methods. The most often used method of registration of metabolomics data acquisition - TOF (MS) was compared with the fast polarity switching MS and auto MS/MS methods with the use of multivariate chemometric analysis (PCA). In all the cases both ionization mode (positive and negative) were studied and the number of the identified compounds was compared. Additionally, various urine sample preparation procedures were tested and it was found that the addition of organic solvents to the sample noticeably reduces the number of entities in the registered profiles. It was also noticed that the auto MS/MS method is the least efficient way to register metabolomic profiles.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 50 条
  • [1] On-line sample preparation and analysis of cortisol in urine by LC-MS/MS.
    Kushnir, MM
    Rockwood, AL
    Nelson, GJ
    Terry, AH
    Meikle, AW
    CLINICAL CHEMISTRY, 2002, 48 (06) : A125 - A125
  • [2] Metabolomic Analysis and Visualization Engine for LC-MS Data
    Melamud, Eugene
    Vastag, Livia
    Rabinowitz, Joshua D.
    ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9818 - 9826
  • [3] Automated and unbiased analysis of LC-MS metabolomic data
    Hnatyshyn, Serhiy
    Shipkova, Petia
    BIOANALYSIS, 2012, 4 (05) : 541 - 554
  • [4] The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
    Saito, Suguru
    Hirao, Yoshitoshi
    Quadery, Ali F.
    Xu, Bo
    Elguoshy, Amr
    Fujinaka, Hidehiko
    Koma, Shohei
    Yamamoto, Keiko
    Yamamoto, Tadashi
    METHODS AND PROTOCOLS, 2019, 2 (02) : 1 - 13
  • [5] Sample preparation in LC-MS bioanalysis
    Hopfgartner, Gerard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (04) : 803 - 804
  • [6] Optimization of sample preparation for transporter protein quantification in tissues by LC-MS/MS
    Jankovskaja, Skaidre
    Kamiie, Junichi
    Rezeli, Melinda
    Gustaysson, Lena
    Sugihara, Yutaka
    Miliotis, Tasso
    Ruzgas, Tautgirdas
    Marko-Varga, Gyorgy
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 164 : 9 - 15
  • [7] Metabolomic analysis-Addressing NMR and LC-MS related problems in human feces sample preparation
    Moosmang, Simon
    Pitscheider, Maria
    Sturm, Sonja
    Seger, Christoph
    Tilg, Herbert
    Halabalaki, Maria
    Stuppner, Hermann
    CLINICA CHIMICA ACTA, 2019, 489 : 169 - 176
  • [8] Quality Assessment of LC-MS Metabolomic Data
    Ranjbar, Mohammad R. Nezami
    Wang, Yue
    Ressom, Habtom W.
    2011 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE WORKSHOPS, 2011, : 1034 - 1036
  • [9] Recent advances in bioanalytical sample preparation for LC-MS analysis
    Singleton, Christopher
    BIOANALYSIS, 2012, 4 (09) : 1123 - 1140
  • [10] Automated processing of sample preparation for homocysteine analysis using LC-MS/MS
    Jun, S.
    Lee, K.
    Song, J.
    CLINICA CHIMICA ACTA, 2022, 530 : S288 - S288