Impact of duration of cryothermal application on clinical efficacy of pulmonary vein isolation using transvenous cryoablation

被引:4
|
作者
Tse, HF [1 ]
Lau, CP [1 ]
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Med, Div Cardiol, Hong Kong, Hong Kong, Peoples R China
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2005年 / 28卷 / 08期
关键词
atrial fibrillation; pulmonary vein; cryoablation;
D O I
10.1111/j.1540-8159.2005.00174.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent studies have demonstrated that transvenous cryoablation is a safe and feasible method for pulmonary vein (PV) isolation for treatment of atrial fibrillation (AF). However, this technique is limited by a much longer ablation time than conventional radiofrequency ablation. The aim of this study was to determine the effect of duration of cryoablation application with double freeze-thaw cycles on clinical efficacy for PV isolation for treatment of AF. Materials and Results: We compared the clinical efficacy and procedural time of cryoablation (CryoCorTM, Son Diego, CA, USA) for segmental PV isolation in 30 patients (mean age 51 13, 20 men) with paroxysmal AF using either double 5-minute (n = 15) or double 2.5-minute (n = 15) freeze-thaw cycle delivered with a 10 F deflectable transvenous catheter. Clinical recurrence of AF and the occurrence of PV stenosis as determined by computer tomography of the thorax were performed at 3- and 12-month follow-up. Acute successful electrical isolation of PV was achieved with cryoablation in 96 of 98 (98%) targeted PVs in 30 patients (mean: 3.2 +/- 0.8 PVs per patient). There were no significant differences between the baseline characteristics, the number of PV isolated per patient, the total number and percentage of effective cryoablation and the acute clinical efficacy between using double 5-minute and double 2.5-minute freezes (P > 0.05). However, the fluoroscopy time (107 +/- 43 vs 138 +/- 113 minutes, P = 0.06) and the procedural time (360 +/- 113 vs 510 +/- 115 minutes, P = 0.01) of using double 2.5-minute freezes was reduced by similar to 30% compared with double 5-minute freezes. At a mean of 20 8 month follow-up, there was no significant difference in the chronic clinical efficacy of cryoablation in terms of freedom from AF in the absence of antiarrhythmic drug therapy between using double 5-minute (6115, 40%) and double 2.5-minute freezes (7/15, 46%, P = 0.98). Conclusion: As compared with double 5-minute freeze, the use of a shorter double 2.5-minute freeze protocol significantly reduces the procedural time without affecting the acute and long-term clinical efficacy of cryoablation to isolate PV for treatment of AF.
引用
收藏
页码:839 / 843
页数:5
相关论文
共 50 条
  • [31] Contrast-enhanced computed tomography for optimizing the outcomes of pulmonary vein isolation with cryoablation -the role of isolation of PVs including carina-
    Yusuke Sakamoto
    Hiroyuki Osanai
    Yuki Tanaka
    Shotaro Hiramatsu
    Hikari Matsumoto
    Kensuke Tagahara
    Hirotaka Hosono
    Shun Miyamoto
    Shun Kondo
    Takahiro Kanbara
    Yoshihito Nakashima
    Hiroshi Asano
    Masayoshi Ajioka
    Journal of Interventional Cardiac Electrophysiology, 2022, 64 : 455 - 461
  • [32] Pulmonary Vein Isolation Using a Second-Generation Cryoballoon Catheter: A Randomized Comparison of Ablation Duration and Method of Deflation
    Andrade, Jason G.
    Dubuc, Marc
    Guerra, Peter G.
    Landry, Evelyn
    Coulombe, Nicolas
    Leduc, Hugues
    Rivard, Lena
    Macle, Laurent
    Thibault, Bernard
    Talajic, Mario
    Roy, Denis
    Khairy, Paul
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (06) : 692 - 698
  • [33] Effect of Left Atrial Pulmonary Vein Angiography on Safety and Efficacy for High-Power, Short-Duration Pulmonary Vein Isolation in Patients with Atrial Fibrillation
    Weyand, Sebastian
    Adam, Viola
    Beuter, Matthias
    Hanger, Simon
    Heinzmann, David
    Schrezenmeier, Willibald
    Seizer, Peter
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [34] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [35] Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation
    Cheema, Aamir
    Dong, Jun
    Dalal, Darshan
    Vasamreddy, Chandrasekhar R.
    Marine, Joseph E.
    Henrikson, Charles A.
    Spragg, David
    Cheng, Alan
    Nazarian, Saman
    Sinha, Sunil
    Halperin, Henry
    Berger, Ronald
    Calkins, Hugh
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (10) : 1080 - 1085
  • [36] Impact of left atrial size on isolation area in the acute phase of pulmonary vein isolation using 28mm cryoballoon
    Chikata, Akio
    Kato, Takeshi
    Usuda, Kazuo
    Fujita, Shuhei
    Maruyama, Michiro
    Nagata, Yoshiki
    Sakagami, Satoru
    Kanamori, Naomi
    Yaegashi, Takanori
    Saeki, Takahiro
    Kusayama, Takashi
    Usui, Soichiro
    Furusho, Hiroshi
    Kaneko, Shuichi
    Takamura, Masayuki
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (07): : 700 - 706
  • [37] Safety and Efficacy of a Novel Approach to Pulmonary Vein Isolation Using Prolonged Apneic Oxygenation
    Gabriels, James K.
    Ying, Xiaohan
    Purkayastha, Subhanik
    Braunstein, Eric
    Liu, Christopher F.
    Markowitz, Steven M.
    Mountantonakis, Stavros
    Thomas, George
    Goldner, Bruce
    Willner, Jonathan
    Goyal, Rajat
    Ip, James E.
    Lerman, Bruce B.
    Carter, Jane
    Bereanda, Nicola
    Fitzgerald, Meghann M.
    Anca, Diana
    Patel, Apoor
    Cheung, Jim W.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (04) : 497 - 507
  • [38] Transvenous cryoablation reduces platelet activation during pulmonary vein ablation compared with radiofrequency energy in patients with atrial fibrillation
    Tse, HF
    Kwong, YL
    Lau, CP
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (10) : 1064 - 1070
  • [39] Impact of energy titration in endoscopic pulmonary vein isolation
    Metzner, Andreas
    Ouyang, Feifan
    Wissner, Eric
    Kuck, Karl-Heinz
    EUROPACE, 2013, 15 (05): : 623 - 624
  • [40] Electroporation-Application beyond pulmonary vein isolation?
    Lee, Adam
    Gerstenfeld, Edward P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1410 - 1411