On-Site Validation of a Microwave Breast Imaging System, before First Patient Study

被引:44
作者
Fasoula, Angie [1 ]
Duchesne, Luc [1 ]
Cano, Julio Daniel Gil [1 ]
Lawrence, Peter [1 ]
Robin, Guillaume [1 ]
Bernard, Jean-Gael [1 ]
机构
[1] MVG Ind, F-91140 Villebon Sur Yvette, France
关键词
breast cancer diagnosis; microwave imaging; medical radar; on-site validation; breast phantoms; TIME-REVERSAL; DIELECTRIC-PROPERTIES; LARGE-SCALE; RADAR; PHANTOMS; TISSUES;
D O I
10.3390/diagnostics8030053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper presents the Wavelia microwave breast imaging system that has been recently installed at the Galway University Hospital, Ireland, for a first-in-human pilot clinical test. Microwave breast imaging has been extensively investigated over the last two decades as an alternative imaging modality that could potentially bring complementary information to state-of-the-art modalities such as X-ray mammography. Following an overview of the main working principles of this technology, the Wavelia imaging system architecture is presented, as are the radar signal processing algorithms that are used in forming the microwave images in which small tumors could be detectable for disease diagnosis. The methodology and specific quality metrics that have been developed to properly evaluate and validate the performance of the imaging system using complex breast phantoms that are scanned at controlled measurement conditions are also presented in the paper. Indicative results from the application of this methodology to the on-site validation of the imaging system after its installation at the hospital for pilot clinical testing are thoroughly presented and discussed. Given that the imaging system is still at the prototype level of development, a rigorous quality assessment and system validation at nominal operating conditions is very important in order to ensure high-quality clinical data collection.
引用
收藏
页数:38
相关论文
共 62 条
  • [1] Aly OAM, 2006, PROG ELECTROMAGN RES, V58, P301
  • [2] [Anonymous], 1996, COMPILATION DIELECTR
  • [3] DIELECTRIC-PROPERTIES OF FEMALE HUMAN BREAST-TISSUE MEASURED INVITRO AT 3.2 GHZ
    CAMPBELL, AM
    LAND, DV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) : 193 - 210
  • [4] ICA-BASED TECHNIQUE FOR RADIATING SOURCES ESTIMATION - APPLICATION TO AIRPORT SURVEILLANCE
    CHAUMETTE, E
    COMON, P
    MULLER, D
    [J]. IEE PROCEEDINGS-F RADAR AND SIGNAL PROCESSING, 1993, 140 (06) : 395 - 401
  • [5] Effect of lesion morphology on microwave signature in 2-D ultra-wideband breast imaging
    Chen, Yifan
    Gunawan, Erry
    Low, Kay Soon
    Wang, Shih-Chang
    Soh, Cheong Boon
    Putti, Thomas Choudary
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (08) : 2011 - 2021
  • [6] Cherniakov M., 2008, BISTATIC RADAR, DOI [10.1002/9780470985755, DOI 10.1002/9780470985755]
  • [7] Conceicao R. C., 2011, Progress In Electromagnetics Research B, V34, P145
  • [8] Conceiçao RC, 2016, BIOL MED PHYS BIOMED, P75, DOI 10.1007/978-3-319-27866-7_5
  • [9] Craddock I., 2008, P 2008 IEEE ANTENNAS, P1, DOI [10.1109/APS.2008.4619673, DOI 10.1109/APS.2008.4619673]
  • [10] Breast tumor characterization based on ultrawideband microwave backscatter
    Davis, Shakti K.
    Van Veen, Barry D.
    Hagness, Susan C.
    Kelcz, Frederick
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) : 237 - 246