New retrofit method to improve the thermal performance of natural draft wet cooling towers based on the reconstruction of the aerodynamic field

被引:29
作者
Chen, Xuehong [1 ]
Sun, Fengzhong [1 ]
Chen, Youliang [2 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] Huadian Elect Power Res Inst, Hangzhou 310000, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural draft wet cooling tower; Thermal performance; Air duct; Air deflector; Hot model test; Numerical simulation; COUNTER-FLOW; PREDICTION; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2018.12.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer deterioration that occurs in the inner rain zone weakens the thermal performance of natural draft wet cooling towers (NDWCTs). Existing NDWCT retrofit methods including the air deflectors and the cross wall have limited effects on this deterioration. In this paper, we propose a new retrofit method in which air ducts are installed in the rain zone and air deflectors are installed around the air inlet to improve the total tower thermal performance. To clarify the effect and mechanism of our retrofit method, a hot test for a NDWCT model is performed under various crosswind velocities, and a 3D numerical model for a NDWCT with air deflectors and air ducts is established and validated. Using the proposed method, the thermal performance of a NDWCT is substantially improved with less crosswind sensitivity. It is found that the flow diversion efficiency of the air deflectors weakens the adverse impact of the ambient crosswind on air inflow of the tower, and the additional ambient air introduced through the air ducts enhances the heat transfer in the central rain zone. Compared with the single effect of the air deflectors or the cross wall, the combined effect of the air ducts and air deflectors is more efficient in improving the thermal performance of NDWCTs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:671 / 680
页数:10
相关论文
共 29 条
  • [1] CFD simulation of wet cooling towers
    Al-Waked, R
    Behnia, M
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (04) : 382 - 395
  • [2] Enhancing performance of wet cooling towers
    Al-Waked, Rafat
    Behnia, Masud
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (10) : 2638 - 2648
  • [3] Crosswinds effect on the performance of natural draft wet cooling towers
    Al-Waked, Rafat
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) : 218 - 224
  • [4] Experimental investigation of the performance of a counter-flow, packed-bed mechanical cooling tower
    Bedekar, SV
    Nithiarasu, P
    Seetharamu, KN
    [J]. ENERGY, 1998, 23 (11) : 943 - 947
  • [5] Bosnjakovic F., 1965, Technical Thermodynamics
  • [6] Experimental research of the cross walls effect on the thermal performance of wet cooling towers under crosswind conditions
    Chen, Youliang
    Sun, Fengzhong
    Wang, Hongguo
    Mu, Nasi
    Gao, Ming
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 4007 - 4013
  • [7] Modelling of cooling tower splash pack
    Dreyer, AA
    Erens, PJ
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (01) : 109 - 123
  • [8] Du Guangsheng, 2007, ENG FLUID MECH
  • [9] Heat Transfer Enhancement of the Air-Cooling Tower with Rotating Wind Deflectors under Crosswind Conditions
    Du, Xueping
    Han, Dongtai
    Zhu, Qiangmin
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (04):
  • [10] Experimental research of heat transfer performance on natural draft counter flow wet cooling tower under cross-wind conditions
    Gao, Ming
    Sun, Feng-zhong
    Wang, Kai
    Shi, Yue-tao
    Zhao, Yuan-bin
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (07) : 935 - 941