An application of hydraulic tomography to a deep coal mine: Combining traditional pumping tests with water inrush incidents

被引:53
|
作者
Mao, Deqiang [1 ]
Liu, Zaibin [2 ,3 ]
Wang, Wenke [3 ]
Li, Shucai [4 ]
Gao, Yaoquan [2 ]
Xu, Zhenhao [4 ]
Zhang, Chi [5 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
[2] China Coal Technol & Engn Grp, Xian Res Inst Co, Xian 710054, Shaanxi, Peoples R China
[3] Changan Univ, Sch Environm Sci & Engn, Xian 710054, Shaanxi, Peoples R China
[4] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Shandong, Peoples R China
[5] Univ Kansas, Dept Geol, Lawrence, KS 66045 USA
关键词
Hydraulic tomography; Pumping test; Water inrush incident; GROUNDWATER-FLOW; POROUS-MEDIA; AQUIFER; TRANSMISSIVITY; INFORMATION; INVERSION; TRANSPORT; MODEL; HEAD;
D O I
10.1016/j.jhydrol.2018.09.058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Water inrush incidents threaten the safety of coal mining. Understanding of hydrogeologic parameter distributions is critical for preventing water-related hazards in coal mines. During the deep mining ( > 1000 m) under the North China Plain, water from water-bearing strata discharges into coal seams through geologic conduits (i.e. water inrush) due to the fractured zone under the floor of working faces. In this study, a water inrush incident was exploited as an active stimulus. A 3D groundwater flow model was built for the eighth member of the Middle Ordovician system in Xingdong coal mine. Using this model and an inverse approach, we first checked if the data from the incident and an independent pumping test carry non-redundant information about the heterogeneity of the mine. Afterward, we combined these datasets to conduct a large-scale (approximately 10 km) hydraulic tomography (HT) analysis. The estimated hydraulic conductivity distribution from the HT analysis is found consistent with the distribution of known geologic faults. That is, a cluster of faults is characterized as a high-conductivity zone. A high conductivity zone is identified at locations close to the water inrush location, which is the high cement consumption zone during the grouting project. Finally, results of this study promote exploiting the water inrush events as a HT survey for mapping geologic structures over a large area.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 4 条
  • [1] Potential of hydraulic tomography in exploring the preferential flowpaths of water inrush in coal mine areas
    Wang, Wei
    Zhao, Weidong
    Qian, Jiazhong
    Ma, Lei
    Wang, Dejian
    Hou, Xiaoliang
    JOURNAL OF HYDROLOGY, 2021, 602
  • [2] Application of dynamic weight in coal mine water inrush source identification
    Cui, Mengke
    Huang, Pinghua
    Hu, Yongsheng
    Chai, Shuangwei
    Zhang, Yanni
    Li, Yuanmeng
    ENVIRONMENTAL EARTH SCIENCES, 2024, 83 (02)
  • [3] Identification of preferential flow paths by hydraulic tomography compared with tracer test and the groundwater contour map in coal mine water hazard area
    Qian, Jiazhong
    Wang, Wei
    Ma, Lei
    Dang, Baoquan
    Sun, Xiaofan
    JOURNAL OF HYDROLOGY, 2024, 631
  • [4] Application of a new evaluation method for floor water inrush risk from the Ordovician fissure confined aquifer in Xiayukou coal mine, Shanxi, China
    Xiao, Lele
    Wu, Qiang
    Niu, Chao
    Dai, Gelian
    Wang, Shengquan
    Ren, Dengjun
    Luo, Shoutao